class MtasStControlAccessProfile

ManagedElement
+-MtasFunction
+-MtasServices
+-MtasSt
+-MtasStControlAccessProfile

An MtasStControlAccessProfile MO represents a set of properties describing certain behavior for handling of PBX routes. At initial start, the system creates a default MtasStControlProfile where the attributes specifying PBX route handling behavior are set to default values. All PBXs will as default refer to the MtasStControlProfile=Default which means that after an initial start, the default St Control Access profile will be used. A New StControlAccessprofile reference can be provisioned for a PBX in HSS.

Attributes
MtasString1to128DT
key
mandatory
noNotification
restricted
mtasStControlAccessProfile
This attribute defines the primary key of MtasStControlAccessProfile and this section describes the MtasStControlAccessProfile attributes.
MtasString1to128DT
mtasStControlAccessProfileErrorCodes = 408,504,500
This list contains final response codes that indicate permanent error on a PBX route. The route is forced into Error guard state.

Specification: A string consisting of a list of 3 digit integers seperated by the character ','.It is also possible to specify a range: 403-410 The min value of the 3-digit integer is '300' and max value '599'
Takes effect: New session
MtasTimerMSec00000to065535DT
mtasStControlAccessProfileErrorGuard = 900
This attributes defines how long time in seconds a route stays in error guard state. Value of 0 means the guard time never times out.

Takes effect: New session
MtasTimerMSec00000to065535DT
mtasStControlAccessProfileTimeout = 2000
This attributes defines how long time in milliseconds ST AS waits before it decides a PBX route is out of order. The route is forced into Error guard state. Value of 0 means the timeout is disabled.

Takes effect: New session

  class MtasStControlAccessProfile