MtasLicenses, UC Routing License Absent
MTAS

Contents

1Introduction
1.1Alarm Description
1.2Prerequisites

2

Procedure

1   Introduction

This instructions concerns alarm handling.

1.1   Alarm Description

The alarm is raised when a valid Business Line (BL) Unified Communication (UC) routing license is not available in the Network License Server (NeLS) and the following conditions apply:

The alarm is cleared when at least one of the following conditions apply:

For more information, refer to MTAS Licenses.

The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.

Table 1    Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

The BL Routing license is not present.

MTAS is unable to get license details from NeLS.

The NeLS server is unreachable, or the license is unavailable, has expired, or is corrupted.

NeLS server

MTAS cannot route calls to the UC System for VoLTE UC users.

TLS(1) configuration in the ME(2)

Possible IP network issue

DNS(3) server

Network interface

(1)  Transport Layer Security (TLS)

(2)  Managed Element (ME)

(3)  Domain Name System (DNS)


The alarm attributes are described in Table 2.

Table 2    Alarm Attributes

Attribute Name

Attribute Value

Major Type

193

Minor Type

6619222

Managed Object Class

MtasLicenses

Managed Object Instance

MtasFunction.applicationName=MtasFunction,MtasLicenses.mtasLicenses=0

Specific Problem

MtasLicenses, UC Routing License Absent

Event Type

communicationsAlarm (2)

Probable Cause

Unavailable(14)

Additional Text

No License found or License Server Not reachable or License expired or License Server in LOCKED mode

Perceived Severity

major (4)

Additional Info

-

1.2   Prerequisites

This section describes the possible documents, tools, and conditions needed before performing steps to clear the alarm.

1.2.1   Documents

This instruction references the following documents:

1.2.2   Tools

Not applicable.

1.2.3   Conditions

Before starting this procedure, ensure that the following conditions are met:

2   Procedure

To clear the alarm:

  1. If there is any network-related alarm on the ME, act on it first.
  2. If there is a License Management, Autonomous Mode Activated alarm on the ME, act on it.
  3. If there is a License Management, Key File Fault alarm on the ME, act on it.
  4. Check if a valid vMtasBLUCReRouting license (CXC4012170) is installed. For more information, refer to View License Information.
  5. If no license is present or if the granted status of the license is false, and expiration shows an already elapsed date, proceed with Step 8.
  6. Check the alarm status. Is the alarm still active?

    Yes: Continue with the next step.

    No: Proceed with Step 9.

  7. Perform data collection. For more information, refer to Data Collection Guideline for MTAS.
  8. Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
  9. Job is completed.


Copyright

© Ericsson AB 2017. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    MtasLicenses, UC Routing License Absent         MTAS