1 Introduction
This instructions concerns alarm handling.
1.1 Alarm Description
The alarm is raised when the SIP Trunking Basic services are enabled through the mtasStAdministrativeState attribute, but the license allowing use of the services is not available in the Network License Server (NeLS).
The alarm is cleared when a valid license is installed or when the mtasStAdministrativeState attribute is disabled.
For more information, refer to MTAS Licenses.
The possible alarm causes and the corresponding fault locations are described in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
MTAS is unable to get the license details from NeLS. |
The NeLS server is unreachable, or the relevant license is unavailable, has expired, or is corrupted. |
NeLS server |
MTAS cannot handle SIP Trunking Basic services. | |
|
Possible IP network issue | ||||
|
Network interface |
(1) Transport Layer Security (TLS)
The alarm attributes are described in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
6619241 |
|
Managed Object Class |
|
|
Managed Object Instance |
MtasFunction.applicationName=MtasFunction,MtasLicenses.mtasLicenses=0 |
|
Specific Problem |
|
|
Event Type |
communicationsAlarm (2) |
|
Probable Cause |
m3100Unavailable(14) |
|
Additional Text |
No License found or License Server Not reachable or License expired or License Server in LOCKED mode |
|
Perceived Severity |
critical (3) |
|
Additional Info |
- |
1.2 Prerequisites
This section describes the possible documents, tools, and conditions needed before performing steps to clear the alarm.
1.2.1 Documents
This instruction references the following documents:
- Data Collection Guideline for MTAS
- License Management
- License Management, Autonomous Mode Activated
- License Management, Key File Fault
- MTAS Licenses
- View License Information
1.2.2 Tools
Not applicable.
1.2.3 Conditions
The following conditions must apply:
- An MtasLicenses, SIP Trunking AS Base License Absent alarm is raised.
- No ongoing maintenance activities are affecting the network or network elements.
- The user has proper authority to handle configuration management of the network elements.
- An Ericsson Command-Line Interface (ECLI) session in Exec mode is in progress.
2 Procedure
To clear the alarm:
- If there is a network-related alarm on the ME, act on it first.
- If there is a License Management, Autonomous Mode Activated alarm on the ME, act on it.
- If there is a License Management, Key File Fault alarm on the ME, act on it.
- Check if a valid vMtasSTBase license (CXC4012189) is installed. For more information, refer to View License Information.
- If no license is present, or if the granted status of the license is false, and expiration shows an already elapsed date, proceed with Step 8.
- Check the alarm status. Is the alarm still active?
Yes: Continue with the next step.
No: Proceed with Step 9.
- Perform data collection. For more information, refer to Data Collection Guideline for MTAS.
- Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
- Job is completed.