MtasMmtNoSubscription, Number of originating calls received without subscription exceed the limitation
MTAS

Contents

1Introduction
1.1Alarm Description
1.2Prerequisites

2

Procedure

1   Introduction

This document concerns alarm handling.

1.1   Alarm Description

This alarm is raised when the number of originating calls received without subscription crosses the arm threshold value of MtasMmtNoSubscriptionCallReceived. A single alarm is raised per MTAS instance.

The alarm is automatically cleared when the number of calls without subscription (MtasMmtNoSubscriptionCallReceived) decreases below the disarm Low value configured in Threshold Monitor Job after a maximum of 60 minutes (Granularity Period of the Threshold Monitor).

The default arm and disarm threshold values are respectively 300 and 150.

The possible alarm causes and fault locations are described in Table 1.

Table 1    Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

Number of MtasMmt calls without subscription crosses arm threshold value.

Number of originating calls received without subscription exceeded the limitation.

Number of calls without subscription are higher than expected in a time period.

MtasMmt

No Impact.


The alarm indicates that there are more number of calls without subscription received in the network in a time period.

Note:  
The alarm can appear as a result of the maintenance activity.

The alarm attributes are described in Table 2.

Table 2    Alarm Attributes

Attribute Name

Attribute Value

Major Type

193

Minor Type

6619244

Managed Object Class

MtasMmtNoSubscription

Managed Object Instance

MtasFunction.applicationName=MtasFunction,MtasServices.mtasService=0,MtasMmt.mtasMmt=0,MtasMmtNoSubscription.mtasMmtNoSubscription=0

Specific Problem

MtasMmtNoSubscription, Number of originating calls received without subscription exceed the limitation

Event Type

qualityOfServiceAlarm (3)

Probable Cause

x733ThresholdCrossed (351)

Additional Text

Received NoServiceMode calls exceed the limitation in given period

Perceived Severity

minor (5)

1.2   Prerequisites

This section describes the possible documents, tools, and conditions needed before performing steps to clear the alarm.

1.2.1   Documents

No documents are needed.

1.2.2   Tools

No tools are required.

1.2.3   Conditions

No conditions.

2   Procedure

Not applicable.



Copyright

© Ericsson AB 2017. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    MtasMmtNoSubscription, Number of originating calls received without subscription exceed the limitation         MTAS