After any Configuration of CarSelDialedStringAnalysisTable, the CarSelDialedStringAnalysisTableSynchronization is set to TRUE. This means the Carrier Select application will be notified that new configuration has been made and it starts reading the new data in to its cache table. The Carrier Select application sets the CarSelDialedStringAnalysisTableSynchronization FALSE when it is ready. When DialedStringAnalysisTableSynchronization is TRUE no new configuration can be made in CarSelDialedStringAnalysisTable until the flag is set to FALSE again.