1 Alarm Description
This is an alarm of severity MAJOR.
The alarm is raised when an attempt to start a process failed.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
An attempt to start a process failed. |
|
Internal cluster network |
Normally this is a non-fatal alarm; the ECM automatically makes new attempts to start the process. If the alarm is raised more than 5 times within 5 minutes or is persistent for 5 minutes, follow the procedure in Section 2. |
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
1586561539 |
|
Managed Object Class |
Not Applicable |
|
Source |
3GPPSystemComponents.Name=System Components,Ecm.Name=<*>,Host.Address=<*>,ClassID=<*>,InstanceType=<*>,Process.InstanceID=<*> |
|
Specific Problem |
Start Process Failed |
|
Perceived Severity |
SEVERITY_MAJOR |
2 Procedure
2.1 Handle Alarm SS7 CAF Start Process Failed
Prerequisites
- No documents are referenced.
- No tools are required.
- The following condition must apply:
- The alarm is raised multiple times or is persistent.
Steps
- Collect the ss7trace.log located in /opt/sign/log.
Also collect the current configuration which is located in the folder /opt/sign/etc. Collect the file active.om.cim and all the files with the extension *.cnf.
- Contact next level of support and provide the files collected in Step 1 .