SS7 CAF ECM Goes Active
Call Session Control Function

Contents


1   Alarm Description

This is an alarm of severity MINOR.

The alarm is issued when an ECM has taken the active role.

Table 1    SS7 CAF ECM Goes Active Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

  • The system has recently been started and ECM has determined which host that should be active.

  • The active ECM is moved either because of user request or automatically.

The active ECM (its only one active ECM in the cluster) has moved to another node in the SS7 CAF cluster.

  • System start.

  • ECM is moved.

  • Internal cluster network problems.

Internal cluster network

This notification requires no remedial action, it is an informative alarm.


If this alarm is raised more than 5 times within 5 minutes or is persistent for 5 minutes, there is some problem with the internal cluster network.

Table 2    SS7 CAF ECM Goes Active Alarm Attributes

Attribute Name

Attribute Value

Major Type

193

Minor Type

1586561542

Managed Object Class

Not Applicable

Source

3GPPSystemComponents.Name=<*>,Ecm.Name=<*>,Host.Address=<*>

Specific Problem

SS7 CAF ECM Goes Active

Perceived Severity

SEVERITY_MINOR

2   Procedure

2.1   Handle Alarm SS7 CAF ECM Goes Active

Prerequisites

Steps

  1. Check other alarms from the cluster concerning the internal cluster network status.
  2. Collect the ecm.log and ss7trace.log located in /opt/sign/log.

    Also collect the current configuration which is located in the folder /opt/sign/etc. Collect the file active.om.cim and all the files with the extension *.cnf.

  3. Contact next level of support and provide the files collected in Step 2.