SS7 CAF ECM Goes Down
Call Session Control Function

Contents


1   Alarm Description

This is an alarm of severity MINOR.

This alarm is issued when ECM detects a failure that it is unable to recover from.

Table 1    SS7 CAF ECM Goes Down Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

  • ECM has run out of memory.

  • ECM has used all its message buffers for sending of internal messages.

  • ECM has detected corrupt internal data structures.

ECM detected a failure that it is unable to recover from.

  • Running out of memory

  • Corrupted data structure

Internal cluster network

The ECM process is shut down immediately.


The ECM process is automatically restarted by the SS7 CAF AMF process.


If the alarm is raised more than 5 times in 5 minutes or is persistent for 5 minutes, follow the procedure in Section 2.

Table 2    SS7 CAF ECM Goes Down Alarm Attributes

Attribute Name

Attribute Value

Major Type

193

Minor Type

1586561538

Managed Object Class

Not Applicable

Source

3GPPSystemComponents.Name=<*>,Ecm.Name=<*>,Host.Address=<*>

Specific Problem

ECM Goes Down

Perceived Severity

SEVERITY_MINOR

2   Procedure

2.1   Handle Alarm ECM Goes Down

Prerequisites

Steps

  1. Collect the ss7trace.log located in /opt/sign/log.

    Also collect the current configuration which is located in the folder /opt/sign/etc. Collect the file ecm.log and active.om.cim and all the files with the extension *.cnf.

  2. Contact next level of support and provide the files collected in Step 1.