1 Alarm Description
This is an alarm of severity MAJOR.
The alarm is issued when the SM NTF Agent loses its connection towards the stack to the OAM process.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
Operation and Maintenance connection lost |
SM NTF Agent loses its connection towards the stack to the OAM process. |
Network Cluster |
Any alarms or notifications sent by the stack during the time the connection is down are lost. The connection is automatically established once the OAM process is restarted or the internal cluster network is available again. If this alarm is raised for more than 1 minute, follow the procedure in Section 2. |
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
1586563328 |
|
Managed Object Class |
Not Applicable |
|
Source |
SM_NTF_Agent=<*> |
|
Specific Problem |
OAM Connection Lost |
|
Perceived Severity |
SEVERITY_MAJOR |
2 Procedure
2.1 Handle Alarm SS7 CAF OAM Connection Lost
Prerequisites
- No documents are referenced.
- No tools are required.
- The following condition must apply:
- The alarm is raised and persistent (raised for more than 1 min).
Steps
- Check other alarms from the cluster concerning the internal cluster network status.
- Enable trace on OAM as follows:
- Collect the ss7trace.log located in /opt/sign/log.
Also collect the current configuration that is located in folder /opt/sign/etc. Collect the file active.om.cim and all the files with the extension *.cnf.
- Contact next level of support and provide the files collected in Step 3.