1 Alarm Description
The alarm is raised when a Diameter connection has failed.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
A Diameter connection has failed. |
Format error of Capabilities-Exchange-Request (CER)/Capabilities Exchange Answer (CEA) messages |
The received message has not been coded according to the diameter standard for coding parameters |
Examine the log in /opt/cdclsv/storage/log/lpmsv to determine fault reason |
Missing connection between one or more Diameter peer nodes, which can decrease the throughput of messages between Diameter applications |
|
One or more Attribute-Value Pairs (AVPs) are missing | ||||
|
A vendor-defined mandatory AVP is received and that AVP is not defined in the receiving node | ||||
|
Configuration fault |
The security configuration is not the same on both sides |
Software configuration | ||
|
An application is not installed on both sides | ||||
|
The number of connections is not equal on both sides | ||||
|
Link inactivity |
A connection to a Diameter peer is broken because of link inactivity without response to a watchdog message |
Network interface | ||
|
IP network failure |
IP network failure |
IP network | ||
|
Socket failure |
Socket | |||
|
Malformed message |
Network | |||
|
System error |
Internal |
Software | ||
|
Handler restarted |
Internal |
Software | ||
|
Link not handled |
Internal |
Software | ||
|
Internal |
Software | |||
|
Internal error, CP user IDs conflict |
Internal |
Software | ||
|
Connection failure |
Network configuration fault |
Misconfigured IP addresses or port numbers | ||
|
Temporary fault |
Any of the Diameter peer nodes |
The alarm is cleared automatically in the following situations:
- Related peer node is disabled
When a peer node is disabled, all vDicos Diameter Link Failure alarms on connections related to this peer node are cleared and a new vDicos, Diameter Peer Node Disabled alarm is raised.
- Own node is disabled
When the own node is disabled, alarms for connections (and peer nodes) related to the own node are cleared and a new vDicos, Diameter Own Node Disabled alarm is raised for the own node.
- A Diameter link is disabled
When a Diameter link for this connection is disabled, the alarm is cleared and a new vDicos, Diameter Link Disabled alarm is raised for the connection.
2 Procedure
2.1 Handle Alarm vDicos, Diameter Link Failure
Prerequisites
- This instruction references the following documents:
- No tools are required.
- The following conditions must apply:
- The alarm is raised.
- Diameter configuration data are correctly.
- An Ericsson Command-Line Interface (ECLI) session in Exec mode is in progress.
Steps
- Check the additionalText attribute of the alarm.
- Select action according to the attribute text:
- If Format error of CER/CEA messages, proceed with Section 2.2.
- If Configuration fault, proceed with Section 2.3.
- If Link inactivity, IP network failure, or Connection failure, proceed with Section 2.4.
- If System error, proceed with Section 2.5.
2.2 Handle Format Error of CER/CEA Messages
Steps
- Wait for automatic reconnection.
- Check the status of the links to the peer indicated by
the alarm, for example:
>dn ManagedElement=NODE06ST,XyzFunction=xyz,DIA-CFG-Application=DIA,DIA-CFG-StackContainer=abc,DIA-CFG-PeerNodeContainer=abc,DIA-CFG-NeighbourNode=node12.ericsson.com\23abc
(DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>show-table -m DIA-CFG-Conn -p connId,linkStatus
The following is an example output:
============================================ | connId | linkStatus | ============================================ | abc\23node12....com\23conn1 | Down | | abc\23node12....com\23conn2 | Up | ============================================
- Is at least one of the connections established for the
peer node?
Yes: Continue with the next step.
No: Proceed with Step 10.
- Navigate to the DIA-CFG-Conn Managed
Object (MO) with link status Down, for
example:
>dn ManagedElement=NODE06ST,XyzFunction=xyz,DIA-CFG-Application=DIA,DIA-CFG-StackContainer=abc,DIA-CFG-PeerNodeContainer=abc,DIA-CFG-NeighbourNode=node12.ericsson.com\23abc,DIA-CFG-Conn=abc\23node12.ericsson.com\conn1
- Disable and re-enable the connection:
(DIA-CFG-Conn=abc\23node12.ericsson.com\conn1>configure
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>enabled=false
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>commit -s
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>enabled=true
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>commit
- Verify the setting:
(DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>show enabled
enabled=true
- Navigate up one step to the peer node:
(DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>up
- Check the status of the links again, for example:
(DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>show-table -m DIA-CFG-Conn -p connId,linkStatus
The following is an example output:
============================================ | connId | linkStatus | ============================================ | abc\23node12....com\23conn1 | Up | | abc\23node12....com\23conn2 | Up | ============================================
- Are there additional connections with link status Down?
Yes: Proceed with Step 4.
No: Proceed with Step 12.
- Disable and re-enable
the peer node, for example:
(DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>configure
(config-DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>enabled=false
(config-DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>commit -s
(config-DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>enabled=true
(config-DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>commit
- Verify the setting:
(DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>show enabled
enabled=true
- Check the link status
of the connections:
(DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>show-table -m DIA-CFG-Conn -p connId,linkStatus
The following is an example output:
============================================ | connId | linkStatus | ============================================ | abc\23node12....com\23conn1 | Up | | abc\23node12....com\23conn2 | Up | ============================================
- Is the connection established?
Yes: Continue with the next step.
No: Proceed with Step 15.
- Is the alarm cleared?
Yes: Proceed with Step 17.
No: Continue with the next step.
- Perform data collection, refer to Data Collection Guideline.
- Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
- Job is completed.
2.3 Handle Configuration Fault
Steps:
- Wait for automatic reconnection.
- Is the number of connections equal on both sides?
Yes: Continue with the next step.
No: Add or remove connections to get equal numbers on both sides.
- Are any of the connections established for the peer node?
Yes: Continue with the next step.
No: Disable the peer node.
- Is all but one connection established for the peer node?
Yes: Disable the connection.
No: Continue with the next step.
- Note:
- Make sure that both nodes have the same applications installed and that Transport Layer Security (TLS) is not required by the other Diameter node. Enable the peer node, or enable the connection again.
- Is the connection established, that is, the link status
goes to Upper Part (UP)?
Yes: Proceed with Step 9.
No: Continue with the next step
- Check the value of the blockReason attribute in the DIA-CFG-Conn MO, for
example:
>dn ManagedElement=NODE06ST,XyzFunction=xyz,DIA-CFG-Application=DIA,DIA-CFG-StackContainer=abc,DIA-CFG-PeerNodeContainer=abc,DIA-CFG-NeighbourNode=node12.ericsson.com\23abc,DIA-CFG-Conn=abc\23node12.ericsson.com\conn1
(DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>show blockReason
The value of the blockReason attribute contains the result code. The following is an example output:
blockReason=3007(application is unsupported)
- Perform one of the following actions, based on the result
code:
- 3007(application is unsupported): Install the needed application.
- 3010(the peer is unknown): Define the peer node.
- 5010(there is no common application): Install the needed application.
- 5012(not enough resources defined): Define more connections for the peer node.
- Disable the connection and enable it again.
- Is the
alarm cleared?
Yes: Continue with the next step.
No: Clear the alarm manually and contact the next level of maintenance support. Further actions are outside the scope of this Operating Instruction.
- Job is completed.
2.4 Handle Link Inactivity, IP Network Failure, or Connection Failure
Steps
- Wait for automatic reconnection.
- Check the link status of the DIA-CFG-Conn MO
indicated by the alarm, for example:
>dn ManagedElement=NODE06ST,XyzFunction=xyz,DIA-CFG-Application=DIA,DIA-CFG-StackContainer=abc,DIA-CFG-PeerNodeContainer=abc,DIA-CFG-NeighbourNode=node12.ericsson.com\23abc,DIA-CFG-Conn=abc\23node12.ericsson.com\conn1
(DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>show linkStatus
The following is an example output:
linkStatus=Down
- Is at least one of the connections established for the
peer node?
Yes: Continue with the next step.
No: Proceed with Step 6.
- Disable and re-enable the connection:
(DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>configure
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>enabled=false
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>commit -s
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>enabled=true
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>commit
- Is the connection established?
Yes: Proceed with Step 11.
No: Continue with the next step.
- Disable and re-enable the
peer node, for example:
(DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>configure
(config-DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>enabled=false
(config-DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>commit -s
(config-DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>enabled=true
(config-DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>commit
- Verify the setting:
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>show enabled
enabled=true
- Wait for automatic reconnection.
- Check the link status:
(DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>show linkStatus
The following is an example output:
linkStatus=Up
- Is the connection established?
Yes: Continue with the next step.
No: Proceed with Step 12.
- Is the alarm cleared?
Yes: Proceed with Step 17.
No: Proceed with Step 15.
- Use tools ping and traceroute to check
the connection to the peer node.
Can the peer be reached within 10 seconds?
Yes: Proceed with Step 15.
No: Continue with the next step.
- Contact the network administrator about a possible network fault.
- Proceed with Step 17.
- Perform data collection, refer to Data Collection Guideline.
- Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
- Job is completed.
2.5 Handle System Error, Handler Restarted, Link not Handled, Internal Error, Connection to SCTP FE Lost or Internal Error, CP User IDs Conflict
Steps
- Wait for automatic reconnection.
- Disable and re-enable the connection:
(DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>configure
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>enabled=false
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>commit -s
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>enabled=true
(config-DIA-CFG-Conn=abc\23node12.ericsson.com\conn1)>commit
- Perform data collection, refer to Data Collection Guideline.
- Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
- Job is completed.