LPM, Load Regulation Limit Passed

Contents


1   Alarm Description

The alarm is raised when the monitored system resources exceed the configured Load Regulation thresholds.

Table 1    LPM, Load Regulation Limit Passed Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

Incorrect dimensioning

The load regulation dimensioning is incorrect.

System is not dimensioned to handle the engineered capacity

Dimensioning process

Calls are rejected by load regulation

Software fault leading to high resource use

A software fault leads to high resource use.

Software fault

Leaked use of resources by software

Expected incoming overload

The load regulation algorithm estimates from the load trend an incoming overload.

Sudden increase in the number of incoming executionPermitted() calls.

Application design fault or unexpected external traffic.

2   Procedure

2.1   Handle Alarm LPM, Load Regulation Limit Passed

Prerequisites

Steps

  1. Perform a health check, refer to Health Check documentation available in the library.
  2. Perform data collection, refer to Data Collection Guideline.
  3. Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
  4. Job is completed.