Instances in

Management Information Base

CscfPm_CscfSipOverloadControlStatistics_PmGroup



Pm=1
    +-PmGroup=CscfSipOverloadControlStatistics
NameValue
categoryFeature CscfFunction, Class CscfSipOverloadControlStatistics
consistentDatatrue
generationIMS
moClass.moClassNameCscfSipOverloadControlStatistics
moClass.mimNameCscfFunction
moClass.mimVersion1
moClass.mimRelease0
pmGroupIdCscfSipOverloadControlStatistics
switchingTechnologyPacket Switched
validitytrue

        +-MeasurementType=cscfAverageSipReportingOverloadControlValue
NameValue
aggregationAVG
collectionMethodGAUGE
conditionThe counter is updated every second with current calculated oc-value based on the cluster average resource utilization level when the reporting role for SIP Overload Control is enabled
descriptionThis counter shows the average oc-value generated for the SIP Overload Control function during a granularity period
measurementNamecscfAverageSipReportingOverloadControlValue
measurementResultfloat
measurementStatusUSED
measurementTypeIdcscfAverageSipReportingOverloadControlValue
multiplicity1

        +-MeasurementType=cscfPeakSipReportingOverloadControlValue
NameValue
aggregationMAX
collectionMethodGAUGE
conditionThe counter is updated every second with current calculated oc-value based on the cluster average resource utilization level when the reporting role for SIP Overload Control is enabled
descriptionThis counter shows the maximum oc-value for the SIP Overload Control function during a granularity period
measurementNamecscfPeakSipReportingOverloadControlValue
measurementResultinteger
measurementStatusUSED
measurementTypeIdcscfPeakSipReportingOverloadControlValue
multiplicity1

        +-MeasurementType=cscfSipReportingOverloadControlDuration
NameValue
aggregationSUM
collectionMethodCC
conditionThe counter is incremented by 1 in each second during the overload period when the oc-value is larger than zero for the reporting role of SIP Overload Control
descriptionThis counter shows the number of seconds which the node spent in overload condition during a granularity period
measurementNamecscfSipReportingOverloadControlDuration
measurementResultinteger
measurementStatusUSED
measurementTypeIdcscfSipReportingOverloadControlDuration
multiplicity1

        +-MeasurementType=cscfSipReportingOverloadControlPeriods
NameValue
aggregationSUM
collectionMethodCC
conditionThe counter is incremented by 1 when the node entered the overload mode, when the oc-value becomes larger than zero, for the reporting role of SIP Overload Control
descriptionThis counter shows the number of times when the node entered the overload operation mode during a granularity period
measurementNamecscfSipReportingOverloadControlPeriods
measurementResultinteger
measurementStatusUSED
measurementTypeIdcscfSipReportingOverloadControlPeriods
multiplicity1