1 Alarm Description
The threshold alarm CSCF ENUM Responses Resulting In Malformatted RN is raised when the number of ENUM responses received with malformatted Number Portability parameters reached or exceeds the threshold value.
The alarm is associated to the Performance Management counter CscfGnpEnumResponseMalformatted.
The alarm is raised when the number of malformatted Routing Numbers (RN) has reached or exceeded its configured thresholdHigh within the time period configured by thresholdRateOfVariation and granularityPeriod.
The alarm is automatically ceased when it reaches or goes below the configured thresholdLow value.
The default values related to this alarm are: thresholdRateOfVariation=PER_GP, granularityPeriod=FIVE_MIN, thresholdHigh=6, and thresholdLow=0. This means that when the counter value is 6 or higher, the alarm is raised when the Granularity Period is ended. The alarm is ceased when the counter CscfGnpEnumResponseMalformatted has reached a value of 0 at the end of a Granularity Period.
- Note:
- The thresholds for raising and ceasing this alarm are configurable.
The default Distinguished Name for the threshold is ManagedElement=<node_name>, SystemFunctions=1, Pm=1, PmJob= CscfRoutingInformationThreshold,
MeasurementReader=cscfGnpEnumResponseMalformattedMeasReader, PmThresholdMonitoring=cscfGnpEnumResponseMalformatted.
It is not possible to change threshold values once they have been set. To change a threshold, first the PmThresholdMonitoring instance must be deleted and recreated with required thresholdHigh and thresholdLow.
For more information, refer to Performance Management.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
The PM counter CscfGnpEnumResponseMalformatted has reached or exceeded its configured upper threshold value. |
The number of ENUM responses received with malformatted Number Portability RN or Number Portability Database Indicator (NPDI) parameters has reached or exceeded the configured threshold value. |
The ENUM Number Portability RN or NPDI parameters in the ENUM response are malformatted. |
ENUM routing table has erroneous configuration data. |
ENUM provisioning errors are resulting in malformatted ENUM responses towards the CSCF. Calls to ported numbers are not properly routed. |
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
6684695 |
|
Managed Object Class |
MeasurementReader |
|
Managed Object Instance |
ManagedElement=<node_name>,SystemFunctions=1, Pm=1, PmJob= CscfRoutingInformationThreshold, MeasurementReader=cscfGnpEnumResponseMalformattedMeasReader |
|
Specific Problem |
|
|
Event Type |
processingError (4) |
|
Probable Cause |
x733ThresholdCrossed (351) |
|
Additional Text |
cscfGnpEnumResponseMalformatted, ENUM provisioning errors are resulting in malformatted ENUM responses towards the CSCF. Calls to ported numbers may not be routed properly. |
|
Perceived Severity |
major (4) |
2 Procedure
2.1 Handle Alarm CSCF ENUM Responses Resulting in Malformatted RN
Prerequisites
- This instruction references the following documents:
- Before starting this procedure, ensure that the following
tool is available:
- ENUM Provisioning tool such as IPWorks
- The following condition must apply:
- The alarm is raised.
Steps
- Note:
- If the reason for the alarm has disappeared after the Granularity Period, the alarm automatically ceases.
- Find the tel URIs that generate faulty ENUM responses.
The information can be found in the application logs.
- Correct the faulty ENUM entries.
Use the ENUM provisioning tool or interface (for example, IPWorks) to make sure that the ENUM entries are no longer malformatted and that they follow the correct SIP syntax.
The alarm ceases after the number of faulty ENUM responses reaches or becomes lower than the configured thresholdLow for a given PM scan interval.
- Has the alarm ceased?
Yes: Proceed with Step 5.
No: Continue with the next step.
- If the alarm is not ceased, consult the next level of
maintenance support.
Further actions are outside the scope of this instruction.
- Job is completed.

Contents