# DocTitle:     vCSCF 1.11.0 Complement Master Parameter Value List for BCF
# DocNo:        27/190 73-AVA 901 30/2
# DocDate:      2019-06-20
# DocRev:       J
# MomDocNo:     190 04-CRA 119 1740
# MomDocRev:    GD
# Revision History
# A: On demand configuration for BCF functionality if it is required.
# B: Only updated for new MOM rev (FV) to PDB Server.
# C: Only updated for new MOM rev (FX) to PDB Server.
# D: Only updated for new MOM rev (FY) to PDB Server.
# E: Only updated for new MOM rev (FZ) to PDB Server.
# F: Only updated for new MOM rev (GA) to PDB Server.
# G: Only updated for new MOM rev (GB) to PDB Server.
# H: Only updated for new MOM rev (GC) to PDB Server.
# J: Only updated for new MOM rev (GD) to PDB Server.

# This MPVL is introduced in vCSCF 1.11. where the MPVLs are restructured and eVIP configuration is moved from evip.xml to MPVL. BCF function is also moved to this separate MPVL.
# During this consolidation the following changes are made compared to vCSCF 1.10:

# - Configuration sets the bcfEnabled parameter to true.
# - Setting of BcfDomainNameEntry from SSL.
# - BCF port 5060 is hardcoded according to the recommendation for TCP and UDP.
# - The evipAlbId for the signaling ALB is named "cscf_sig_sp1" instead of "ln_sig_sc" to align with the ambitions from IMS to have a common network for the IMS VNFs.
# - cscfTrustedGatewayEntry and cscfTrustedASEntry were added with the IP address of the BCF.
-->
<parameterlist>
   <parameter network_element="CSCF" module="CSCF" parametername="managedElementId" ims_fixed="{{node_name}}" ims_mobile="{{node_name}}" converged="{{node_name}}" node_standalone="{{node_name}}" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="0" defaultvalue="[empty]" moc="ManagedElement" moi="ManagedElement.managedElementId={{node_name}}" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="applicationName" ims_fixed="1" ims_mobile="1" converged="1" node_standalone="1" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="1" defaultvalue="[empty]" moc="CscfFunction" moi="ManagedElement.managedElementId={{node_name}},CscfFunction.applicationName=1" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="applicationName" ims_fixed="CSCF" ims_mobile="CSCF" converged="CSCF" node_standalone="CSCF" category="[empty]" type="[empty]" comment="Created automatically" paraCR="[empty]" ID="2" defaultvalue="[empty]" moc="CSCF-Application" moi="ManagedElement.managedElementId={{node_name}},CscfFunction.applicationName=1,CSCF-Application.applicationName=CSCF" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="bcfDomainNameEntry" ims_fixed="{{CSCF_DOMAIN_BCF}}" ims_mobile="{{CSCF_DOMAIN_BCF}}" converged="{{CSCF_DOMAIN_BCF}}" node_standalone="{{CSCF_DOMAIN_BCF}}" category="[empty]" type="multi line" comment="[empty]" paraCR="[empty]" ID="3" defaultvalue="[empty]" moc="CSCF-Application" moi="ManagedElement.managedElementId={{node_name}},CscfFunction.applicationName=1,CSCF-Application.applicationName=CSCF" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="bcfEnabled" ims_fixed="true" ims_mobile="true" converged="true" node_standalone="true" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="4" defaultvalue="[empty]" moc="CSCF-Application" moi="ManagedElement.managedElementId={{node_name}},CscfFunction.applicationName=1,CSCF-Application.applicationName=CSCF" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="cscfTrustedGatewayEntry" ims_fixed="{{CSCF_IP_BCF}}/32" ims_mobile="{{CSCF_IP_BCF}}/32" converged="{{CSCF_IP_BCF}}/32" node_standalone="{{CSCF_IP_BCF}}/32" category="[empty]" type="multi line" comment="[empty]" paraCR="[empty]" ID="5" defaultvalue="[empty]" moc="CscfAuthenticationClass" moi="ManagedElement.managedElementId={{node_name}},CscfFunction.applicationName=1,CSCF-Application.applicationName=CSCF,CscfAuthenticationGroupClass.cscfAuthenticationGroup=0,CscfAuthenticationClass.cscfAuthentication=default" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="cscfTrustedASEntry" ims_fixed="{{CSCF_IP_BCF}}" ims_mobile="{{CSCF_IP_BCF}}" converged="{{CSCF_IP_BCF}}" node_standalone="{{CSCF_IP_BCF}}" category="[empty]" type="multi line" comment="[empty]" paraCR="[empty]" ID="6" defaultvalue="[empty]" moc="CscfAuthenticationClass" moi="ManagedElement.managedElementId={{node_name}},CscfFunction.applicationName=1,CSCF-Application.applicationName=CSCF,CscfAuthenticationGroupClass.cscfAuthenticationGroup=0,CscfAuthenticationClass.cscfAuthentication=default" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="cscfNwIfContainerKey" ims_fixed="0" ims_mobile="0" converged="0" node_standalone="0" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="7" defaultvalue="[empty]" moc="CscfNwIfContainer" moi="ManagedElement.managedElementId={{node_name}},CscfFunction.applicationName=1,CSCF-Application.applicationName=CSCF,CscfNwIfContainer.cscfNwIfContainerKey=0" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="bcfNwIfContainerKey" ims_fixed="0" ims_mobile="0" converged="0" node_standalone="0" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="8" defaultvalue="[empty]" moc="BcfNwIfs" moi="ManagedElement.managedElementId={{node_name}},CscfFunction.applicationName=1,CSCF-Application.applicationName=CSCF,CscfNwIfContainer.cscfNwIfContainerKey=0,BcfNwIfs.bcfNwIfContainerKey=0" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="bcfNetworkInterfaceEntry" ims_fixed="TCP:{{CSCF_IP_BCF}}:5060" ims_mobile="TCP:{{CSCF_IP_BCF}}:5060" converged="TCP:{{CSCF_IP_BCF}}:5060" node_standalone="TCP:{{CSCF_IP_BCF}}:5060" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="9" defaultvalue="[empty]" moc="BcfNetworkInterface" moi="ManagedElement.managedElementId={{node_name}},CscfFunction.applicationName=1,CSCF-Application.applicationName=CSCF,CscfNwIfContainer.cscfNwIfContainerKey=0,BcfNwIfs.bcfNwIfContainerKey=0,BcfNetworkInterface.bcfNetworkInterfaceEntry=TCP:{{CSCF_IP_BCF}}:5060" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="bcfNetworkInterfaceEntry" ims_fixed="UDP:{{CSCF_IP_BCF}}:5060" ims_mobile="UDP:{{CSCF_IP_BCF}}:5060" converged="UDP:{{CSCF_IP_BCF}}:5060" node_standalone="UDP:{{CSCF_IP_BCF}}:5060" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="10" defaultvalue="[empty]" moc="BcfNetworkInterface" moi="ManagedElement.managedElementId={{node_name}},CscfFunction.applicationName=1,CSCF-Application.applicationName=CSCF,CscfNwIfContainer.cscfNwIfContainerKey=0,BcfNwIfs.bcfNwIfContainerKey=0,BcfNetworkInterface.bcfNetworkInterfaceEntry=UDP:{{CSCF_IP_BCF}}:5060" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="transportId" ims_fixed="1" ims_mobile="1" converged="1" node_standalone="1" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="11" defaultvalue="[empty]" moc="Transport" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="evipId" ims_fixed="1" ims_mobile="1" converged="1" node_standalone="1" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="12" defaultvalue="[empty]" moc="Evip" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1,Evip.evipId=1" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="evipAlbsId" ims_fixed="1" ims_mobile="1" converged="1" node_standalone="1" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="13" defaultvalue="[empty]" moc="EvipAlbs" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1,Evip.evipId=1,EvipAlbs.evipAlbsId=1" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="evipAlbId" ims_fixed="cscf_sig_sp1" ims_mobile="cscf_sig_sp1" converged="cscf_sig_sp1" node_standalone="cscf_sig_sp1" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="14" defaultvalue="[empty]" moc="EvipAlb" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1,Evip.evipId=1,EvipAlbs.evipAlbsId=1,EvipAlb.evipAlbId=cscf_sig_sp1" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="evipFlowPoliciesId" ims_fixed="1" ims_mobile="1" converged="1" node_standalone="1" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="15" defaultvalue="[empty]" moc="EvipFlowPolicies" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1,Evip.evipId=1,EvipAlbs.evipAlbsId=1,EvipAlb.evipAlbId=cscf_sig_sp1,EvipFlowPolicies.evipFlowPoliciesId=1" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="evipFlowPolicyId" ims_fixed="4cscf_bcf_tcp_5060" ims_mobile="4cscf_bcf_tcp_5060" converged="4cscf_bcf_tcp_5060" node_standalone="4cscf_bcf_tcp_5060" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="16" defaultvalue="[empty]" moc="EvipFlowPolicy" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1,Evip.evipId=1,EvipAlbs.evipAlbsId=1,EvipAlb.evipAlbId=cscf_sig_sp1,EvipFlowPolicies.evipFlowPoliciesId=1,EvipFlowPolicy.evipFlowPolicyId=4cscf_bcf_tcp_5060" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="protocol" ims_fixed="tcp" ims_mobile="tcp" converged="tcp" node_standalone="tcp" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="17" defaultvalue="[empty]" moc="EvipFlowPolicy" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1,Evip.evipId=1,EvipAlbs.evipAlbsId=1,EvipAlb.evipAlbId=cscf_sig_sp1,EvipFlowPolicies.evipFlowPoliciesId=1,EvipFlowPolicy.evipFlowPolicyId=4cscf_bcf_tcp_5060" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="targetPool" ims_fixed="sig_PL_rr" ims_mobile="sig_PL_rr" converged="sig_PL_rr" node_standalone="sig_PL_rr" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="18" defaultvalue="[empty]" moc="EvipFlowPolicy" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1,Evip.evipId=1,EvipAlbs.evipAlbsId=1,EvipAlb.evipAlbId=cscf_sig_sp1,EvipFlowPolicies.evipFlowPoliciesId=1,EvipFlowPolicy.evipFlowPolicyId=4cscf_bcf_tcp_5060" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="destPort" ims_fixed="5060" ims_mobile="5060" converged="5060" node_standalone="5060" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="19" defaultvalue="[empty]" moc="EvipFlowPolicy" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1,Evip.evipId=1,EvipAlbs.evipAlbsId=1,EvipAlb.evipAlbId=cscf_sig_sp1,EvipFlowPolicies.evipFlowPoliciesId=1,EvipFlowPolicy.evipFlowPolicyId=4cscf_bcf_tcp_5060" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="addressFamily" ims_fixed="ipv4" ims_mobile="ipv4" converged="ipv4" node_standalone="ipv4" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="20" defaultvalue="[empty]" moc="EvipFlowPolicy" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1,Evip.evipId=1,EvipAlbs.evipAlbsId=1,EvipAlb.evipAlbId=cscf_sig_sp1,EvipFlowPolicies.evipFlowPoliciesId=1,EvipFlowPolicy.evipFlowPolicyId=4cscf_bcf_tcp_5060" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="dest" ims_fixed="{{CSCF_IP_BCF}}" ims_mobile="{{CSCF_IP_BCF}}" converged="{{CSCF_IP_BCF}}" node_standalone="{{CSCF_IP_BCF}}" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="21" defaultvalue="[empty]" moc="EvipFlowPolicy" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1,Evip.evipId=1,EvipAlbs.evipAlbsId=1,EvipAlb.evipAlbId=cscf_sig_sp1,EvipFlowPolicies.evipFlowPoliciesId=1,EvipFlowPolicy.evipFlowPolicyId=4cscf_bcf_tcp_5060" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="evipFlowPolicyId" ims_fixed="4cscf_bcf_udp_5060" ims_mobile="4cscf_bcf_udp_5060" converged="4cscf_bcf_udp_5060" node_standalone="4cscf_bcf_udp_5060" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="22" defaultvalue="[empty]" moc="EvipFlowPolicy" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1,Evip.evipId=1,EvipAlbs.evipAlbsId=1,EvipAlb.evipAlbId=cscf_sig_sp1,EvipFlowPolicies.evipFlowPoliciesId=1,EvipFlowPolicy.evipFlowPolicyId=4cscf_bcf_udp_5060" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="protocol" ims_fixed="udp" ims_mobile="udp" converged="udp" node_standalone="udp" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="23" defaultvalue="[empty]" moc="EvipFlowPolicy" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1,Evip.evipId=1,EvipAlbs.evipAlbsId=1,EvipAlb.evipAlbId=cscf_sig_sp1,EvipFlowPolicies.evipFlowPoliciesId=1,EvipFlowPolicy.evipFlowPolicyId=4cscf_bcf_udp_5060" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="targetPool" ims_fixed="sig_PL_rr" ims_mobile="sig_PL_rr" converged="sig_PL_rr" node_standalone="sig_PL_rr" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="24" defaultvalue="[empty]" moc="EvipFlowPolicy" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1,Evip.evipId=1,EvipAlbs.evipAlbsId=1,EvipAlb.evipAlbId=cscf_sig_sp1,EvipFlowPolicies.evipFlowPoliciesId=1,EvipFlowPolicy.evipFlowPolicyId=4cscf_bcf_udp_5060" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="destPort" ims_fixed="5060" ims_mobile="5060" converged="5060" node_standalone="5060" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="25" defaultvalue="[empty]" moc="EvipFlowPolicy" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1,Evip.evipId=1,EvipAlbs.evipAlbsId=1,EvipAlb.evipAlbId=cscf_sig_sp1,EvipFlowPolicies.evipFlowPoliciesId=1,EvipFlowPolicy.evipFlowPolicyId=4cscf_bcf_udp_5060" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="addressFamily" ims_fixed="ipv4" ims_mobile="ipv4" converged="ipv4" node_standalone="ipv4" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="26" defaultvalue="[empty]" moc="EvipFlowPolicy" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1,Evip.evipId=1,EvipAlbs.evipAlbsId=1,EvipAlb.evipAlbId=cscf_sig_sp1,EvipFlowPolicies.evipFlowPoliciesId=1,EvipFlowPolicy.evipFlowPolicyId=4cscf_bcf_udp_5060" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="dest" ims_fixed="{{CSCF_IP_BCF}}" ims_mobile="{{CSCF_IP_BCF}}" converged="{{CSCF_IP_BCF}}" node_standalone="{{CSCF_IP_BCF}}" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="27" defaultvalue="[empty]" moc="EvipFlowPolicy" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1,Evip.evipId=1,EvipAlbs.evipAlbsId=1,EvipAlb.evipAlbId=cscf_sig_sp1,EvipFlowPolicies.evipFlowPoliciesId=1,EvipFlowPolicy.evipFlowPolicyId=4cscf_bcf_udp_5060" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="evipVipsId" ims_fixed="1" ims_mobile="1" converged="1" node_standalone="1" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="28" defaultvalue="[empty]" moc="EvipVips" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1,Evip.evipId=1,EvipAlbs.evipAlbsId=1,EvipAlb.evipAlbId=cscf_sig_sp1,EvipVips.evipVipsId=1" delta="[empty]"/>
   <parameter network_element="CSCF" module="CSCF" parametername="evipVipId" ims_fixed="{{CSCF_IP_BCF}}" ims_mobile="{{CSCF_IP_BCF}}" converged="{{CSCF_IP_BCF}}" node_standalone="{{CSCF_IP_BCF}}" category="[empty]" type="[empty]" comment="[empty]" paraCR="[empty]" ID="29" defaultvalue="[empty]" moc="EvipVip" moi="ManagedElement.managedElementId={{node_name}},Transport.transportId=1,Evip.evipId=1,EvipAlbs.evipAlbsId=1,EvipAlb.evipAlbId=cscf_sig_sp1,EvipVips.evipVipsId=1,EvipVip.evipVipId={{CSCF_IP_BCF}}" delta="[empty]"/>
</parameterlist>