1 Alarm Description
The alarm CSCF, End-Of-Selection Analysis Internal Loop Detected is raised when more than 25 Next End-Of-Selection (EOS) table entries have been traversed in succession for a session. At initialization of the alarm, EOS analysis for this session is ended and normal CSCF error handling takes place.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
CSCF End of Selection Analysis Internal Loop Detected. |
EOS Analysis internal loop detection: More than 25 Next EOS table entries have been traversed in succession for a given session in the CSCF. |
The received SIP error response included in the alarm is causing more than 25 next EOS table hops, which means that there were no matching profiles in the current configuration of the EOS Analysis when starting in the indicated EOS case. This is regarded as being a loop in the analysis. |
The attribute cscfEosCaseTableEntryId in the Managed Object Class CscfEosCaseTableEntry describes the name of the EOS where the first non-matching profile was encountered. |
The traffic cases causing this alarm are managed according to normal procedures, that is as if the EOS analysis is not invoked. |
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
6684703 |
|
Managed Object Class |
CscfEosApplication |
|
Managed Object Instance |
ManagedElement=<node_name>,CscfFunction=1,CscfEosApplication=CscfEos |
|
Specific Problem |
CSCF, End-Of-Selection Analysis Internal Loop Detected |
|
Event Type |
processingErrorAlarm (4) |
|
Probable Cause |
x733ConfigurationOrCustomizationError (307) |
|
Additional Text |
Format: [initial entry in the table] <SIP Error code>, Reason=<value>; cause=<value>. |
|
Perceived Severity |
major (4) |
(1) Example: eos_tc056,480, Reason: SIP; cause=480
2 Procedure
2.1 Handle Alarm CSCF, End-Of-Selection Analysis Internal Loop Detected
Prerequisites
- This instruction references the following documents:
- No tools are required.
- The following condition must apply:
- The alarm is raised.
Steps
- Find the following information in the Additional Text alarm attribute:
- Find the EOS case name in cscfEosCaseTableEntryId.
- Compare the referenced cscfEosMatchProfileTableEntryId parameters to the received SIP error response status code and Reason header.
- Perform one of the following actions:
- Perform one of the following actions:
- Repeat Step 3 until a match is obtained.
- Remove the indicated EOS case name from the application configuration.
- Note:
- If the intention is that the received SIP error code and Reason header must not result in any alternative routing, introduce a match of the combination and then specify the result exit for that cscfEosCaseRouteName to avoid alarms for this traffic scenario.
- Set cscfEosInternalLoopAlarmReset to true to cease the alarm.
For more information about the configuration management parameters, refer to Managed Object Model (MOM) and CSCF Configuration Management.
- Has the alarm ceased?
Yes: Proceed with Step 9.
No: Continue with the next step.
- If the alarm is not ceased, consult the next level of
maintenance support.
Further actions are outside the scope of this instruction.
- Job is completed.