Start Threshold Monitoring Job

Contents


1   Description

This instruction describes how to start a threshold monitoring job. A threshold monitoring job is started to enable the reporting of threshold alarms for the corresponding measurement types. This is usually done when the managed element is operational and manageable as part of the normal operations.

2   Procedure

2.1   Start Threshold Monitoring Job

Prerequisites

Steps

  1. Navigate to the PmJob managed object, for example:

    >dn ManagedElement=NODE06ST,SystemFunctions=1,Pm=1,PmJob=POT_Thr_Job

  2. Enter Config mode:

    (PmJob=POT_Thr_Job)>configure

  3. Set the PmJob state to ACTIVE:

    (config-PmJob=POT_Thr_Job)>requestedJobState=ACTIVE

  4. Commit the PmJob managed objectconfiguration:

    (config-PmJob=POT_Thr_Job)>commit

  5. Verify the result:

    (PmJob=POT_Thr_Job)>show -v

    The following is an example output:

    PmJob=POT_Thr_Job
       compressionType=[] <empty>
       currentJobState=ACTIVE <read-only>
       granularityPeriod=FIFTEEN_MIN <default>
       jobControl=FULL <default> <read-only>
       jobGroup=[] <empty>
       jobPriority=MEDIUM <default>
       jobType=THRESHOLDJOB
       pmJobId="POT_Thr_Job"
       reportContentGeneration=CHANGED_ONLY <default>
       reportingPeriod=FIFTEEN_MIN <default>
       requestedJobState=ACTIVE <default>
       MeasurementReader=POT_mr
    Note:  
    An alarm notification is issued at the end of the reporting period if thresholdHigh in the PmThresholdMonitoring managed object has been exceeded.