DBS, Data Access Service, Connection has been Lost

Contents


1   Alarm Description

The alarm is raised when any of the configured Data Access Service (DAS) database connections fail. This way an operator can fix the problem even while the service is still operational. If all connections are lost, then DAS raises the DBS, Data Access Service, Database Unreachable alarm.

DAS continuously tries to re-establish the connection to the database server. If it succeeds, the alarm ceases automatically.

The alarm ceases if the DataService is set to LOCKED, but that does not fix the problem indicated by the alarm.

Table 1    DBS, Data Access Service, Connection has been Lost Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

Database connection down

DAS cannot establish a configured connection to the database, or the authentication fails.

The network address or the authentication parameters of the database differ from the ones specified in the DAS configuration.

LdapServerConnection Managed Object (MO) in the related DataService MO.

If no redundant connections are available, then DAS cannot return data from the database. Functions of the node that need access to external data may not work properly.

 

The database server is not working.

Database server.

There is ongoing maintenance work on the network.

Network between DAS and the database server.

Failure occurs in the network between DAS and the database server.

Note:  
An alarm can appear as a result of the maintenance activity.

Table 2    Alarm Attributes

Attribute Name

Attribute Value/Interpretation

Major Type

193

Minor Type

933890

MO Class

LdapServerConnection

Source

<connectionId>

Specific Problem

DBS, Data Access Service, Connection has been Lost

Event Type

COMMUNICATIONSALARM

Probable Cause

connectionEstablishmentError (22)

Perceived Severity

Minor

2   Procedure

2.1   Handle Alarm DBS, Data Access Service, Connection has been Lost

Prerequisites

Steps

  1. Are there any other transmission-related alarms on the same network as DAS uses?

    Yes: Proceed with Step 13.

    No: Continue the next step.

  2. Is the faulty MO identified?

    Yes: Proceed with Step 4.

    No: Continue with the next step.

  3. Show the Distinguished Name (DN) of the faulty MO, for example:

    >show-table ManagedElement=1,SystemFunctions=1,Fm=1 -m FmAlarm -p source,specificProblem --condition (majorType=193 && minorType=933890)

  4. Check the connection parameters of the faulty MO, for example:

    >show all ManagedElement=1,SystemFunctions=1,Das=1,DataService=foo,LdapServerConnection=bar

    The following is an example output:

    uri="ldap://123.123.123.123:389/uid=admin,ou=system"
  5. Are the connection parameters under the selected LdapServerConnectionMO correct?

    Yes: Proceed with Step 13.

    No: Continue with the next step.

  6. Navigate to the DataService MO, for example:

    >ManagedElement=1,SystemFunctions=1,Das=1,DataService=foo

  7. Enter configuration mode:

    (DataService=foo)>configure

  8. Lock DAS:

    (config-DataService=foo)>administrativeState=LOCKED

    (config-DataService=foo)>commit -s

  9. Set the necessary attributes, for example:

    (config-DataService=foo)>connection=1

    (config-DataService=foo)>password=<server password>

    (config-DataService=foo)>type=LDAP

    (config-DataService=foo)>uri="ldap://123.123.123.123:389/uid=admin,ou=system"

  10. Commit the settings:

    (config-DataService=foo)>commit -s

  11. Unlock DAS:

    (config-DataService=foo)>administrativeState=UNLOCKED

    (config-DataService=foo)>commit

  12. Does the alarm show up again after unlocking DAS?

    Yes: Continue with the next step.

    No: Proceed with Step 18.

  13. Is any maintenance work going on that affects the connection between DAS and the database is in progress on the database server or on the network.

    Yes: Wait for the maintenance to finish. Proceed with Step 16.

    No: Continue with the next step.

  14. Contact the related site to check for faulty network components or connections.
  15. Take actions to correct the network issues.
  16. Is the alarm cleared?

    Yes: Proceed with Step 18.

    No: Continue with the next step.

  17. Consult the next level of maintenance support. Further actions are outside the scope of this instruction.