C-Diameter, Diameter Measurement Threshold Crossed

Contents


1   Alarm Description

This generic C-Diameter threshold based alarm was raised because at the end of the granularity period (GP) the measured value for one of the DiameterCC measurement types was higher than the configured threshold.

Note:  
C-Diameter does not deliver Threshold Job for its measurement types. It is up to the C-Diameter Applications to define and document these. Make sure, that the related application documentation is available.

For the list of the DiameterCC measurement types and their properties, see DiameterCC Measurements.

For more details on Performance Management alarms in CBA environment, see Reference [1].

In the subsequent GP the threshold based alarm is cleared automatically in the following cases:

The alarm can also be cleared if the related Threshold Reader or its Threshold Monitor is deleted or disabled

2   Procedure

2.1   Generic Handling of Alarm C-Diameter, PMF Threshold Crossed

Prerequisites

Steps

  1. Based on the information found in the alarm's fields, identify the C-Diameter Application which issued the alarm.

    Check the related PmJob and its MeasurementReader in the source attribute of the alarm, for example:

    >show all ManagedElement=1,SystemFunctions=1,Fm=1,FmAlarm=16 FmAlarm=16,source
    source="ManagedElement=1,SystemFunctions=1,Pm=1,PmJob=AppTHJob,MeasurementReader=1:DiaNode=server1.operator1.com"

  2. List the configured MeasurementReader to find the related C-Diameter measurement type and its properties in DiameterCC Measurements.

    >show ManagedElement=1,SystemFunctions=1,Pm=1,PmJob=AppTHJob,MeasurementReader=1,measurementSpecification,measurementTypeRef

    measurementTypeRef="ManagedElement=1,SystemFunctions=1,Pm=1,PmGroup=DiaNode,MeasurementType=Diameter.TxBytes.Total"

  3. Locate the C-Diameter Application's documentation describing appropriate measures for the situation.
  4. Is there a specific Application OPI found?

    Yes: Follow the instructions mentioned in that document to clear the alarm. After performing the procedure defined by the C-Diameter Application for the above measurement, proceed with Step 17.

    No: Continue with the next step.

  5. Navigate to the PmJob Managed Object (MO) indicated by alarm source attribute, for example:

    >ManagedElement=1,SystemFunctions=1,Pm=1,PmJob=ApplicationThresholdJob

  6. Check the value of attribute granularityPeriod:

    (PmJob=ApplicationThresholdJob)>show granularityPeriod

    The following is an example output:

    granularityPeriod=FIVE_MIN
  7. Wait up to the time of the granularity period for the alarm to be cleared automatically.
  8. Is the alarm cleared?

    Yes: The measurement peak was most probably caused by transient events. No manual intervention is required, proceed with Step 17.

    No: Continue with the next step.

  9. In case no related application documentation is found and the alarm is not ceased automatically during the next granularity period, navigate to the appropriate PmThresholdMonitoring MO, for example:

    (PmJob=ApplicationThresholdJob)>MeasurementReader=1,PmThresholdMonitoring=1

  10. Check the values of attributes thresholdHigh and thresholdLow:

    (PmThresholdMonitoring=1)>show

    The following is an example output:

    PmThresholdMonitoring=1
       pmThresholdMonitoringId="1"
       thresholdHigh=1
       thresholdLow=0
       thresholdSeverity=MINOR
  11. With the collected information, contact the network administrator to establish root cause of the fault, for example network dimensioning, alarm threshold values or network configuration fault. Are the attributes thresholdHigh and thresholdLow set to correct values for the measurement type shown in Step 2?

    Yes: Proceed with Step 13.

    No: Continue with the next step.

  12. Set appropriate values for attributes thresholdHigh and thresholdLow, for example:

    (PmThresholdMonitoring=1)>config

    (config-PmThresholdMonitoring=1)>thresholdHigh=2

    (config-PmThresholdMonitoring=1)>commit

    (config-PmThresholdMonitoring=1)>up

  13. Wait for the alarm to be cleared automatically after elapsing of two granularity periods.
  14. Is the alarm cleared?

    Yes: Proceed with Step 17.

    No: Continue with the next step.

  15. Perform data collection, refer to C-Diameter Trouble Report and Support Case Writing Guideline.
  16. Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
  17. Job is completed.