class CscfEosAnalysis

ManagedElement
+-CscfFunction
+-CscfEosApplication
+-CscfEosAnalysis
+-CscfEosCaseTable [1..1]
+-CscfEosMatchProfileTable [1..1]
+-CscfEosRouteTable [1..1]


This is the container for the configuration parameters related to an instance of the
End-of-selection analysis. Currently it is only possible to have one instance.


This MO is created by the system.

Attributes
EOSTableIdDT
key
mandatory
noNotification
restricted
cscfEosAnalysisId
Key attribute used in the CscfEosAnalysis Managed Object instance.
boolean
cscfEosInternalLoopAlarmReset = false
This attribute is used to cease the ”End-Of-Selection Analysis Internal Loop Detected” alarm. If the alarm is raised follow the instructions in the OPI to correct the fault causing the alarm. When the fault has been corrected the alarm is manually ceased by setting this parameter to true. When the alarm has been ceased the attribute will automatically be set to false again by the system.
Integer0to00010DT
cscfEosMaxEosAttempts = 3
This attribute specifies how many times EOS Analysis may be triggered per call/session. If the attribute is set to 0, the EOS Analysis function is disabled.

  class CscfEosAnalysis