Check Alarm Status

Contents


1   Description

This instruction describes how to check the alarm status. The alarm status can be checked as part of preventive maintenance or problem resolution activities. In such situations, a detailed view of the active alarms in the managed element is required.

2   Procedure

2.1   Check Alarm Status

Prerequisites

Steps

  1. Navigate to the Fm managed object, for example:

    >dn ManagedElement=NODE06ST,SystemFunctions=1,Fm=1

  2. Show the alarm list:

    (Fm=1)>show

  3. Show the details of an alarm, for example:

    (Fm=1)>show FmAlarm=1

    The following is an example output:

    FmAlarm=1
       activeSeverity=CRITICAL
       additionalText="The number of files exceeded threshold level <thresholdHigh>
        in ManagedElement=1,SystemFunctions=1,FileM=1,LogicalFs=1,FileGroup=1"
       eventType=Other
       lastEventTime="2017-04-20T10:59:11.137+02:00"
       majorType=193
       minorType=131073
       originalAdditionalText="The number of files exceeded threshold level <thresholdHigh>
        in ManagedElement=1,SystemFunctions=1,FileM=1,LogicalFs=1,FileGroup=1"
       originalEventTime="2017-04-20T10:59:11.137+02:00"
       originalSeverity=CRITICAL
       probableCause=343
       sequenceNumber=36
       source="ManagedElement=1,SystemFunctions=1,Fm=1,FmAlarmModel=FileManagement,=>
         FmAlarmType=FileMNoOfFilesExceeded"
         specificProblem="File Management, Number of Files in FileGroup Exceeded"
  4. Show the detailed alarm status:

    (Fm=1)>show-table -m FmAlarm -p fmAlarmId,source,activeSeverity,specificProblem

    The following is an example output:

    fmAlarmId

    Source

    activeSeverity

    specificProblem

    1

    ManagedElement=1,SystemFunctions=1,Fm=1,FmAlarmModel=FileManagement,⇒
    FmAlarmType=FileMNoOfFilesExceeded

    critical

    File Management, Number of Files in FileGroup Exceeded

    2

    ManagedElement=NODE06ST,SystemFunctions=1,⇒
    Brm=1,BrmBackupManager=SYSTEM_DATA,⇒
    BrmBackupScheduler=SYSTEM_DATA

    major

    BRM, Scheduled Backup Failed

    10

    ManagedElement=NODE06ST,Conn=conn1,⇒
    Stack=CSCFRF,Host=LABSPTOFFCHA2.ericsson.se

    warning

    Diameter, Link Disabled