1 Alarm Description
The alarm is raised when a Diameter peer node has been disabled, either administratively or by the system because of a fault.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
Diameter peer node disabled |
The Diameter peer node has been disabled |
Diameter peer node disabled |
Peer node configuration |
The communication with the peer node is lost |
The alarm is cleared automatically when alarm vDicos, Diameter Own Node Disabled is raised. Alarms for peer nodes related to the own node are cleared and a new alarm is raised for the own node.
2 Procedure
2.1 Handle Alarm vDicos, Diameter Peer Node Disabled
Prerequisites
- This instruction references the following documents:
- No tools are required.
- The following conditions must apply:
- The alarm is raised.
- An Ericsson Command-Line Interface (ECLI) session in Exec mode is in progress.
Steps
- Contact the network or node administrator. Is the node
administratively disabled for maintenance reasons?
Yes: Proceed with Step 8.
No: Continue with the next step.
- Navigate to the DIA-CFG-NeighbourNode managed object, for example:
>dn ManagedElement=NODE06ST,XyzFunction=xyz,DIA-CFG-Application=DIA,DIA-CFG-StackContainer=abc,DIA-CFG-PeerNodeContainer=abc,DIA-CFG-NeighbourNode=node12.ericsson.com\23abc
- Enable the Diameter peer node:
(DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>configure
(config-DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>enabled=true
(config-DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>commit
- Verify the setting:
(DIA-CFG-NeighbourNode=node12.ericsson.com\23abc)>show enabled
enabled=true
- Is the alarm cleared?
Yes: Proceed with Step 8.
No: Continue with the next step.
- Perform data collection, refer to Data Collection Guideline.
- Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
- Job is completed.