1 Introduction
This instruction concerns alarm handling.
1.1 Alarm Description
The threshold alarm CSCF Credit Control Answers Indicate Protocol Errors is issued when there are problems with Credit Control charging Requests (CCR) sent from the Call Session Control Function (CSCF) to the charging system.
Triggering happens when the number of Credit Control Answers (CCA) with protocol errors (code 3xxx) received through Diameter has reached or exceeded its corresponding threshold value.
The alarm is associated to the Performance Management counter cscfCCAProtocolErrors.
The alarm is raised when the number of cscfCCAProtocolErrors has reached or exceeded its configured thresholdHigh within the time period configured by thresholdRateOfVariation and granularityPeriod.
The alarm is automatically ceased when it reaches or goes below the configured thresholdLow value.
The default values related to this alarm are: thresholdRateOfVariation=PER_GP, granularityPeriod=FIVE_MIN, thresholdHigh =2, and thresholdLow=0. This means that when the counter value is 2 or higher, the alarm is raised when the granularity period is ended. The alarm is ceased when the counter cscfCCAProtocolErrors has reached a value of 0 at the end of a granularity period.
- Note:
- The thresholds for raising and ceasing this alarm are configurable.
The default distinguished name for the thresholds is ManagedElement=<node_name>, SystemFunctions=1, Pm=1,
PmJob=CscfChargingStatisticsThreshold, MeasurementReader=cscfCCAProtocolErrorsMeasReader,
PmThresholdMonitoring=cscfCCAProtocolErrors.
It is not possible to change threshold values once they have been set. To change a threshold, first the PmThresholdMonitoring instance must be deleted and recreated with required thresholdHigh and thresholdLow.
For more information, refer to Performance Management.
The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
The PM counter cscfCCAProtocolErrors has reached or exceeded its configured upper threshold value. |
The number of received CCAs with Result-Code 3xxx (protocol errors) for sent CCRs has reached or exceeded the configured threshold. |
Peer entity problems to interpret or manage CCR messages. |
Peer entity Charging Server or protocol compatibilities problems between the CSCF and the Charging Server. |
Sessions receiving these error codes from the charging server will be terminated. |
- Note:
- An alarm can appear as a result of maintenance activity.
The alarm attributes are listed and explained in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
6684686 |
|
Managed Object Class |
MeasurementReader |
|
Managed Object Instance |
ManagedElement=<node_name>,SystemFunctions=1, Pm=1, PmJob=CscfChargingStatisticsThreshold, MeasurementReader=cscfCCAProtocolErrorsMeasReader |
|
Specific Problem |
CSCF Credit Control Answers Indicate Protocol Errors |
|
Event Type |
communication (2) |
|
Probable Cause |
x733ThresholdCrossed (351) |
|
Additional Text |
cscfCCAProtocolErrors, check connection to the charging system, possibly caused by configuration problem. |
|
Perceived Severity |
major (4) |
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
This instruction references the following documents:
1.2.2 Tools
Before starting this procedure, ensure that the following tool is available:
- A Diameter protocol sniffer, refer to RFC 3588 Diameter Base Protocol
1.2.3 Conditions
No conditions.
2 Procedure
- Note:
- If the reason for the alarm has disappeared after the granularity period, the alarm automatically ceases.
Do the following:
- Log on and check that the System Controller (SC) is the
primary processor:
cat/proc/drdb
Primary printout: 0:cs:Connected st:Primary/Secondary id:Consistent
or
Secondary printout: 0:cs:Connected st:Secondary/Primary id:Consistent
- Check the log file and grep on error 3xxx
(protocols errors):
grep “Result-Code= [30” /storage/no-backup/cdclsv/log/lpmsv/*
- Log off the SC.
- Verify that the alarm is matching with the errors in the log.
- Investigate why communication with the Charging Server node fails.
- If the cause is that the alarm threshold is set too low, adjust the alarm threshold.
- Confirm that the alarm has ceased. If the alarm remains, consult the next level of maintenance support. Further actions are outside the scope of this instruction.
- Job is completed.