Instances in

Management Information Base

CscfPm_CscfChargingStatistics_PmGroup



Pm=1
    +-PmGroup=CscfChargingStatistics
NameValue
categoryFeature CscfFunction, Class CscfChargingStatistics
consistentDatatrue
generationIMS
moClass.moClassNameCscfChargingStatistics
moClass.mimNameCscfFunction
moClass.mimVersion1
moClass.mimRelease0
pmGroupIdCscfChargingStatistics
switchingTechnologyPacket Switched
validitytrue

        +-MeasurementType=cscfACABackup
NameValue
aggregationSUM
collectionMethodCC
conditionThe counter is incremented when protocol errors: DIAMETER_UNABLE_TO_DELIVER, DIAMETER_TOO_BUSY and transient failures DIAMETER_OUT_OF_SPACE and ELECTION_LOST are received from Diameter.
cpiHeadingCharging Statistics Counters
descriptionWhen protocol error or no Accounting Response is received on the ACR message the CSCF sends an ACR to the Offline backup process.
measurementNamecscfACABackup
measurementResultinteger
measurementStatusUSED
measurementTypeIdcscfACABackup
multiplicity1

        +-MeasurementType=cscfACAPermanentFailure
NameValue
aggregationSUM
collectionMethodCC
conditionThe counter is incremented when an ACA with protocol errors (code 5xxx) is received from Diameter.
cpiHeadingCharging Statistics Counters
descriptionNumber of Accounting Answers (ACA) with permanent errors (code 5xxx) received from Diameter. The counter is used to raise and cease the threshold alarm CSCF Charging Answers Indicate Permanent Failures. The thresholds for raising and ceasing the alarm are configurable, see alarm OPI for further information.
fmAlarmTypeFm=1,FmAlarmModel=CscfFunction,FmAlarmType=CscfChargingAnswersIndicatePermanentFailures
measurementNamecscfACAPermanentFailure
measurementResultinteger
measurementStatusUSED
measurementTypeIdcscfACAPermanentFailure
multiplicity1

        +-MeasurementType=cscfACAProtocolErrors
NameValue
aggregationSUM
collectionMethodCC
conditionThe counter is incremented when an ACA with protocol errors (code 3xxx)is received from Diameter.
cpiHeadingCharging Statistics Counters
descriptionNumber of Accounting Answers (ACAs) with protocol errors (code 3xxx) received from Diameter. The counter is used to raise and cease the threshold alarm CSCF Charging Answers Indicate Protocol Errors. The thresholds for raising and ceasing the alarm are configurable, see alarm OPI for further information.
fmAlarmTypeFm=1,FmAlarmModel=CscfFunction,FmAlarmType=CscfChargingAnswersIndicateProtocolErrors
measurementNamecscfACAProtocolErrors
measurementResultinteger
measurementStatusUSED
measurementTypeIdcscfACAProtocolErrors
multiplicity1

        +-MeasurementType=cscfACARedirectIndication
NameValue
aggregationSUM
collectionMethodCC
cpiHeadingCharging Statistics Counters
descriptionNumber of Accounting Answers (ACA) with protocol error that the request could not be satisfied with locally and the CSCF will direct the request directly to the server, whose contact information has been added to the response.
measurementNamecscfACARedirectIndication
measurementResultinteger
measurementStatusUSED
measurementTypeIdcscfACARedirectIndication
multiplicity1

        +-MeasurementType=cscfACASuccess
NameValue
aggregationSUM
collectionMethodCC
conditionThe counter is incremented when a successful ACA is received from Diameter.
cpiHeadingCharging Statistics Counters
descriptionNumber of successful Accounting Answers (ACAs) received from Diameter.
measurementNamecscfACASuccess
measurementResultinteger
measurementStatusUSED
measurementTypeIdcscfACASuccess
multiplicity1

        +-MeasurementType=cscfACR
NameValue
aggregationSUM
collectionMethodCC
conditionThe counter is incremented when an ACR is sent from the CSCF to Diameter.
cpiHeadingCharging Statistics Counters
descriptionThe number of Accounting Requests sent.
measurementNamecscfACR
measurementResultinteger
measurementStatusUSED
measurementTypeIdcscfACR
multiplicity1

        +-MeasurementType=cscfCCACreditLimitReached
NameValue
aggregationSUM
collectionMethodCC
conditionThe counter is incremented when transient failure "DIAMETER_CREDIT_LIMIT_REACHED" (4012) is received from Diameter.
cpiHeadingCharging Statistics Counters
descriptionNumber of Credit Control Answers (CCAs) with a transient failure where the end-user's account could not cover the requested service.
measurementNamecscfCCACreditLimitReached
measurementResultinteger
measurementStatusUSED
measurementTypeIdcscfCCACreditLimitReached
multiplicity1

        +-MeasurementType=cscfCCACreditNotApplicable
NameValue
aggregationSUM
collectionMethodCC
conditionThe counter is incremented when transient failure "DIAMETER_CREDIT_LIMIT_REACHED" (4012) is received from Diameter.
cpiHeadingCharging Statistics Counters
descriptionNumber of Credit Control Answers (CCAs) with a transient failure where it is determined that the service can be granted to the end-user, but no further credit control is needed.
measurementNamecscfCCACreditNotApplicable
measurementResultinteger
measurementStatusUSED
measurementTypeIdcscfCCACreditNotApplicable
multiplicity1

        +-MeasurementType=cscfCCAEndUserServiceDenied
NameValue
aggregationSUM
collectionMethodCC
conditionThe counter is incremented when transient failure "DIAMETER_END_USER_SERVICE_DENIED" (4010) is received from Diameter.
cpiHeadingCharging Statistics Counters
descriptionNumber of Credit Control Answers (CCAs) with a transient failure where the server denies the service request due to service restrictions. The counter is used to raise and cease the threshold alarm CSCF Credit Control Answers Indicate End User Service Denied. The thresholds for raising and ceasing the alarm are configurable, see alarm OPI for further information.
fmAlarmTypeFm=1,FmAlarmModel=CscfFunction,FmAlarmType=CscfCCAIndicateEndUserServiceDenied
measurementNamecscfCCAEndUserServiceDenied
measurementResultinteger
measurementStatusUSED
measurementTypeIdcscfCCAEndUserServiceDenied
multiplicity1

        +-MeasurementType=cscfCCAPermanentFailures
NameValue
aggregationSUM
collectionMethodCC
conditionThe counter is incremented when a CCA with permanent failures (code 5xxx) is received from Diameter.
cpiHeadingCharging Statistics Counters
descriptionNumber of Credit Control Answers (CCAs) with permanent failures (code 5xxx) received from Diameter. The counter is used to raise and cease the threshold alarm CSCF Credit Control Answers Indicate Permanent Failures. The thresholds for raising and ceasing the alarm are configurable, see alarm OPI for further information.
fmAlarmTypeFm=1,FmAlarmModel=CscfFunction,FmAlarmType=CscfCCAPermanentFailures
measurementNamecscfCCAPermanentFailures
measurementResultinteger
measurementStatusUSED
measurementTypeIdcscfCCAPermanentFailures
multiplicity1

        +-MeasurementType=cscfCCAProtocolErrors
NameValue
aggregationSUM
collectionMethodCC
conditionThe counter is incremented when a successful CCA is received from Diameter.
cpiHeadingCharging Statistics Counters
descriptionNumber of Credit Control Answers (CCAs) with protocol errors (code 3xxx) received from Diameter. The counter is used to raise and cease the threshold alarm CSCF Credit Control Answers Indicate Protocol Errors. The thresholds for raising and ceasing the alarm are configurable, see alarm OPI for further information.
fmAlarmTypeFm=1,FmAlarmModel=CscfFunction,FmAlarmType=CscfCCAProtocolErrors
measurementNamecscfCCAProtocolErrors
measurementResultinteger
measurementStatusUSED
measurementTypeIdcscfCCAProtocolErrors
multiplicity1

        +-MeasurementType=cscfCCASuccess
NameValue
aggregationSUM
collectionMethodCC
conditionThe counter is incremented when a successful CCA is received from Diameter.
cpiHeadingCharging Statistics Counters
descriptionThe number of successful Credit Control Answers (CCAs).
measurementNamecscfCCASuccess
measurementResultinteger
measurementStatusUSED
measurementTypeIdcscfCCASuccess
multiplicity1

        +-MeasurementType=cscfCCATransientFailures
NameValue
aggregationSUM
collectionMethodCC
conditionThe counter is incremented when a CCA with transient failures (code 4xxx) is received from Diameter
cpiHeadingCharging Statistics Counters
descriptionNumber of Credit Control Answers (CCAs) with transient failures (code 4xxx) received from Diameter.
measurementNamecscfCCATransientFailures
measurementResultinteger
measurementStatusUSED
measurementTypeIdcscfCCATransientFailures
multiplicity1

        +-MeasurementType=cscfCCAUserUnknown
NameValue
aggregationSUM
collectionMethodCC
conditionThe counter is incremented when permanent failure "DIAMETER_USER_UNKNOWN" (5030) is received from Diameter.
cpiHeadingCharging Statistics Counters
descriptionNumber of Credit Control Answers (CCAs) with a permanent failure where the specified end user is unknown in the credit-control server.
measurementNamecscfCCAUserUnknown
measurementResultinteger
measurementStatusUSED
measurementTypeIdcscfCCAUserUnknown
multiplicity1

        +-MeasurementType=cscfCCR
NameValue
aggregationSUM
collectionMethodCC
conditionThe counter is incremented when a CCR is sent from the CSCF to Diameter
cpiHeadingCharging Statistics Counters
descriptionThe number of Credit Control Request (CCR) messages sent.
measurementNamecscfCCR
measurementResultinteger
measurementStatusUSED
measurementTypeIdcscfCCR
multiplicity1

        +-MeasurementType=cscfCurrentStoredRecords
NameValue
aggregationAVG
collectionMethodGAUGE
conditionThe counter is incremented when a Charging Request Transmission Problem is received from Diameter.
cpiHeadingCharging Statistics Counters
descriptionThe average number of stored charging sessions on disk in the last scan period. The counter is used to raise and cease the threshold alarm CSCF Charging Request Transmission Problem. The thresholds for raising and ceasing the alarm are configurable, see alarm OPI for further information.
fmAlarmTypeFm=1,FmAlarmModel=CscfFunction,FmAlarmType=CscfChargingRequestTransmissionProblem
measurementNamecscfCurrentStoredRecords
measurementResultfloat
measurementStatusUSED
measurementTypeIdcscfCurrentStoredRecords
multiplicity1
  mib CscfPm_CscfChargingStatistics_PmGroup