CSCF, Reference to non-existing End-Of-Selection Case Detected
Call Session Control Function

Contents

1Introduction
1.1Alarm Description
1.2Prerequisites

2

Procedure

1   Introduction

This instruction concerns alarm handling.

1.1   Alarm Description

The threshold alarm CSCF, Reference to non-existing End-Of-Selection Case Detected is issued when several non-existing End-of-Selection (EOS) Case Detections are received during traffic.

The alarm is associated to the Performance Management counter cscfNonConfEosCase.

The alarm is raised when the number of non-conformant EOSs has reached or exceeded its configured thresholdHigh within the time period configured by thresholdRateOfVariation and granularityPeriod.

The alarm is automatically ceased when it reaches or goes below the configured thresholdLow value.

The default values related to this alarm are: thresholdRateOfVariation=PER_GP, granularityPeriod=FIVE_MIN, thresholdHigh =1, and thresholdLow=0. This means that when the counter value is 1 or higher, the alarm is raised when the granularity period is ended. The alarm is ceased when the counter cscfNonConfEosCase has reached a value of 0 at the end of a granularity period.

Note:  
The thresholds for raising and ceasing this alarm are configurable. The default distinguished name for the thresholds is ManagedElement=<node_name>, SystemFunctions=1, Pm=1, PmJob=CscfEndOfSelectionThreshold, MeasurementReader= cscfNonConfEosCaseMeasReader, PmThresholdMonitoring=cscfNonConfEosCase.

It is not possible to change threshold values once they have been set. To change a threshold, first the PmThresholdMonitoring instance must be deleted and recreated with required thresholdHigh and thresholdLow.

For more information, refer to Performance Management.


At initialization of the alarm, EOS analysis for this call or session is ended and normal CSCF error handling takes place.

The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.

Table 1    Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

The PM counter cscfNonConfEosCase has reached or exceeded its configured upper threshold value.

Several non-existing EOS Case Detections are received during traffic.

The referenced EOS case does not exist.

Possible EOS table erroneous configuration.

At initialization of the alarm, EOS analysis for this call or session is ended and normal CSCF error handling takes place.

Note:  
An alarm can appear as a result of maintenance activity.

The alarm attributes are listed and explained in Table 2.

Table 2    Alarm Attributes

Attribute Name

Attribute Value

Major Type

193

Minor Type

6684702

Managed Object Class

MeasurementReader

Managed Object Instance

ManagedElement=<node_name>,SystemFunctions=1, Pm=1, PmJob=CscfEndOfSelectionThreshold, MeasurementReader=cscfNonConfEosCaseMeasReader

Specific Problem

CSCF, Reference to non-existing End-Of-Selection Case Detected

Event Type

processingError (4)

Probable Cause

x733ThresholdCrossed (351)

Additional Text

The PM counter cscfNonConfEosCase is keyed with both SUM and individual EOS Cases. The EOS Case indicated by the individual key does not exist.

Perceived Severity

major (4)

1.2   Prerequisites

This section provides information on the documents, tools, and conditions that apply to the procedure.

1.2.1   Documents

This instruction references the following documents:

1.2.2   Tools

No tools are required.

1.2.3   Conditions

No conditions.

2   Procedure

Note:  
If the reason for the alarm has disappeared after the granularity period, the alarm automatically ceases.

Do the following:

  1. The specific EOS Cases that are being referenced by applications are identified from the non-sum keys of the PM measurement cscfNonConfEosCase.
  2. Verify that the intended EOS Case name to be used is not misspelled as a cscfEosCaseTableEntryId parameter in cscfEosCaseTableId and correct it if applicable.
  3. If the indicated EOS Case name is valid and is to be used but does not exist as a cscfEosCaseTableEntryId in cscfEosCaseTableId, configure the indicated EOS Case name and associated parameters in cscfEosCaseTableId. Alternatively, if the indicated EOS Case name is invalid, or has been previously removed from cscfEosCaseTableId, remove the indicated EOS Case name from the application configuration.
  4. If the cause is that the alarm threshold is set too low, adjust the alarm threshold.
  5. Confirm that the alarm has ceased. If the alarm reoccurs, consult the next level of maintenance support. Further actions are outside the scope of this instruction.
  6. Job is completed.


Copyright

© Ericsson AB 2016. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    CSCF, Reference to non-existing End-Of-Selection Case Detected         Call Session Control Function