1 Description
This instruction describes how to create a threshold monitoring job. A new threshold monitoring job can be created by the user to raise threshold alarms on supported measurement types that are currently not monitored through alarms.
2 Procedure
2.1 Create Threshold Monitoring Job
Prerequisites
- No documents are required.
- No tools are required.
- The following conditions must apply:
- A unique PmJob Managed Object (MO) name is chosen. To check names already in use, refer to List Performance Management Jobs.
- The measurement type has threshold alarm support. To check this, refer to List Performance Management Groups and Measurement Types.
- The thresholdLow, thresholdHigh, and thresholdSeverity attributes are known.
- The MeasurementType MO is known.
- An Ericsson Command-Line Interface (ECLI) session in Exec mode is in progress.
Steps
- Navigate to the Pm MO, for example:
>dn ManagedElement=NODE06ST,SystemFunctions=1,Pm=1
- Enter Config mode:
(Pm=1)>configure
- Create a threshold monitoring job, for example:
(config-Pm=1)>PmJob=POT_Thr_Job
- Set the PmJob initial state to STOPPED:
(config-PmJob=POT_Thr_Job)>requestedJobState=STOPPED
- Set attribute jobType to THRESHOLD:
(config-PmJob=POT_Thr_Job)>jobType=THRESHOLDJOB
- Create a measurement
reader for each referred measurement type, for example:
(config-PmJob=POT_Thr_Job)>MeasurementReader=POT_mr
(config-MeasurementReader=POT_mr)>measurementSpecification
(config-measurementSpecification)>measurementTypeRef="ManagedElement=NODE06ST,SystemFunctions=1,Pm=1,PmGroup=DbsPOT,MeasurementType=PotInst.Count"
(config-measurementSpecification)>up
- Create a PmThresholdMonitoring MO, for example:
(config-MeasurementReader=POT_mr)>PmThresholdMonitoring=POT_tm
(config-PmThresholdMonitoring=POT_tm)>thresholdLow=10
(config-PmThresholdMonitoring=POT_tm)>thresholdHigh=100
(config-PmThresholdMonitoring=POT_tm)>thresholdSeverity=MAJOR
- Are more PmThresholdMonitoring MOs to be created?
Yes: Continue with the next step.
No: Proceed with Step 11.
- Note:
- Up to four PmThresholdMonitoring MOs can be created. The intervals of these MOs must not overlap.
- Navigate to the MeasurementReader MO:
(config-PmThresholdMonitoring=POT_tm)>up
- Proceed with Step 7.
- Repeat Step 6 through Step 8 as needed for each referred measurement type.
- Note:
- One MeasurementReader MO is needed for each reference to a MeasurementType MO.
- Commit the changes:
(config-PmThresholdMonitoring=POT_tm)>commit
- Verify the result:
(PmThresholdMonitoring=POT_tm)>up
(MeasurementReader=POT_mr)>up
(PmJob=POT_Thr_Job)>show -v -r
The following is an example output:
PmJob=POT_Thr_Job compressionType=[] <empty> currentJobState=STOPPED <read-only> granularityPeriod=FIFTEEN_MIN <default> jobControl=FULL <default> <read-only> jobGroup=[] <empty> jobPriority=MEDIUM <default> jobType=THRESHOLDJOB pmJobId="POT_Thr_Job" reportContentGeneration=CHANGED_ONLY <default> reportingPeriod=FIFTEEN_MIN <default> requestedJobState=STOPPED MeasurementReader=POT_mr measurementReaderId="POT_mr" measurementReaderNameValue=[] <empty> <read-only> measurementSpecification groupRef=[] <empty> measurementTypeRef="ManagedElement=NODE06ST,⇒ SystemFunctions=1,Pm=1,PmGroup=DbsPOT,MeasurementType=PotInst.Count" [...] PmThresholdMonitoring=POT_tm pmThresholdMonitoringId="POT_tm" thresholdHigh=100 thresholdLow=10 thresholdSeverity=MAJOR