1 Description
This instruction describes how to start a threshold monitoring job. A threshold monitoring job is started to enable the reporting of threshold alarms for the corresponding measurement types. This is usually done when the managed element is operational and manageable as part of the normal operations.
2 Procedure
2.1 Start Threshold Monitoring Job
Prerequisites
- No documents are required.
- No tools are required.
- The following conditions must apply:
- The job name is known.
In this instruction, the job name example is POT_Thr_Job.
- currentJobState for the job is STOPPED.
- An Ericsson Command-Line Interface (ECLI) session in Exec mode is in progress.
- The job name is known.
Steps
- Navigate to the PmJob managed object, for example:
>dn ManagedElement=NODE06ST,SystemFunctions=1,Pm=1,PmJob=POT_Thr_Job
- Enter Config mode:
(PmJob=POT_Thr_Job)>configure
- Set the PmJob state to ACTIVE:
(config-PmJob=POT_Thr_Job)>requestedJobState=ACTIVE
- Commit the PmJob managed
objectconfiguration:
(config-PmJob=POT_Thr_Job)>commit
- Verify the result:
(PmJob=POT_Thr_Job)>show -v
The following is an example output:
PmJob=POT_Thr_Job compressionType=[] <empty> currentJobState=ACTIVE <read-only> granularityPeriod=FIFTEEN_MIN <default> jobControl=FULL <default> <read-only> jobGroup=[] <empty> jobPriority=MEDIUM <default> jobType=THRESHOLDJOB pmJobId="POT_Thr_Job" reportContentGeneration=CHANGED_ONLY <default> reportingPeriod=FIFTEEN_MIN <default> requestedJobState=ACTIVE <default> MeasurementReader=POT_mr
- Note:
- An alarm notification is issued at the end of the reporting period if thresholdHigh in the PmThresholdMonitoring managed object has been exceeded.