SS7 CAF ECM Goes Down
Call Session Control Function

Contents

1Introduction
1.1Alarm Description
1.2Prerequisites

2

Procedure

1   Introduction

This instruction concerns alarm handling.

1.1   Alarm Description

This is an alarm of severity MINOR.

This alarm is issued when ECM detects a failure that it is unable to recover from.

The possible alarm causes, fault locations, and impacts are explained in Table 1.

Table 1    Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

  • ECM has run out of memory

  • ECM has used all its message buffers for sending of internal messages

  • ECM has detected corrupt internal data structures

ECM detected a failure that it is unable to recover from

  • Running out of memory

  • Corrupted data structure

Internal cluster network

The ECM process is shut down immediately.


The ECM process is automatically restarted by the SS7 CAF AMF process.


If the alarm is raised more than 5 times in 5 minutes or is persistent for 5 minutes, follow the procedure in Section 2.

The alarm attributes are listed and described in Table 2.

Table 2    Alarm Attributes

Attribute Name

Attribute Value

Major Type

193

Minor Type

1586561538

Managed Object Class

N/A

Specific Problem

ECM Goes Down

Perceived Severity

SEVERITY_MINOR

1.2   Prerequisites

This section provides information on the documents, tools, and conditions that apply to the procedure.

1.2.1   Documents

No documents are referenced.

1.2.2   Tools

No tools are required.

1.2.3   Conditions

Before starting this procedure, ensure that the following conditions are met:

2   Procedure

Do the following if the alarm is raised multiple times:

  1. Collect the ss7trace.log located in /opt/sign/log.

    Also collect the current configuration which is located in the folder /opt/sign/etc. Collect the file ecm.log and active.om.cim and all the files with the extension *.cnf.

  2. Contact next level of support and provide the files collected in Step 1.


Copyright

© Ericsson AB 2016. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    SS7 CAF ECM Goes Down         Call Session Control Function