Handling Alarms

Contents

1Understanding Fault Management
1.1Key Fault Management Concepts
1.2Resolving a Fault Reported by an Alarm
1.3Active Alarm List
1.4Alarm and Alert History
1.5Alarm Information
1.6Meaning of Alarm Severity

2

Basic Fault Management Procedures

3

Advanced Fault Management Concepts
3.1SNMP Target

4

Advanced Fault Management Procedures

1   Understanding Fault Management

1.1   Key Fault Management Concepts

The Fm and Snmp Managed Objects Classes (MOCs) can be found in the Managed Object Model (MOM). For general information about the Managed Objects, cardinality, and related concepts, refer to Managed Object Model User Guide.

1.2   Resolving a Fault Reported by an Alarm

The alarm resolution workflow consists of the following main steps:

  1. Once an alarm is noticed, the user identifies it based on its Specific Problem and Source.
  2. The user acknowledges it to indicate to other users that the problem is being worked on. This functionality can be provided by Ericsson management systems and is not further described here.
  3. The user finds the corresponding alarm Operating Instructions (OPIs) document, for example, by performing a search in the Active Library Explorer library. Each alarm has an alarm OPI document titled as the Specific Problem. The actual lookup of alarm OPIs can be provided by Ericsson management systems and is not further described here.
  4. To solve the problem, the alarm OPI document is to be used as follows by the user:
    1. Study the possible alarm causes, fault reasons, fault locations, and the potential service impact.
    2. Analyze the alarm information. The alarm information is visible over NETCONF and the Ericsson Command-Line Interface (ECLI).
    3. Execute the procedure to eliminate the problem and eventually clear the alarm.

Figure 1   Problem Resolution Workflow

1.3   Active Alarm List

The Active Alarm List defines the overall alarm status of the system. It consists of all the alarms currently active that is in raised state. The overall system alarm status is qualified by the severity of the active alarms and the number of alarms. The more severe the active alarms are, the more urgent it is to resolve the underlying faults.

1.4   Alarm and Alert History

All alarm state changes including cleared states are recorded in the Alarm Log. All alerts are recorded in the Alert Log.

1.5   Alarm Information

An alarm includes information usable for identification and cause analysis.

Table 1    Description of Alarm Information

Alarm Information

Description

Major Type

The combination of Major Type and Minor Type, which are two numbers, identifies an Alarm Type, which is an alarm category, within the ME. The Alarm Type is the same in different versions of the ME.

Minor Type

Source

The Distinguished Name (DN) of the alarming object. Managed Object (MO) Instance is applicable only to alarms belonging to a managed area, else Source is used.

Specific Problem

Provides further refinement to the information given by Probable Cause and is unique within the ME. Specific Problem is the same in different versions of the ME. The alarm OPI document title exactly matches its value.

Event Type

The general category for the alarm. The values are defined by ITU-T X.733 and X.736 according to RFC 3877.

Probable Cause

Qualifies and provides further information on the reason for the alarm. The values are defined by ITU-T X.733, X.736, M.3100, and GSM 1211 and are included in ERICSSON-ALARM-PC-MIB.

Additional Text

Provides extra textual information. Normally runtime-related information.

Perceived Severity

Provides guidance on the severity of the problem, that is, possible service impact and urgency to act. The value can be changed owing to deployment scenarios or the operation situation. Perceived Severity is to be interpreted according to the Ericsson definition of the 3GPP Perceived Severity values.

Event Time

The time when the alarm was updated, that is, the time for the latest alarm information change or severity change.

1.6   Meaning of Alarm Severity

Table 2    Ericsson Definition of 3GPP Perceived Severity Values

Severity Level

Description

Cleared (1)

Used to clear a previously reported alarm.

Indeterminate (2)

Not used.

Critical (3)

Indicates that a condition that affects service has occurred and an immediate corrective action is required. Such a severity can be reported, for example, when an MO becomes out of service and its capability must be restored. This severity requires an immediate action, even outside working hours.

Major (4)

Indicates that a condition that affects service has occurred and an urgent corrective action is required. Such a severity can be reported, for example, when a service degrades in the MO capacity and its full capability must be restored. This severity requires an immediate action within working hours.

Minor (5)

Indicates that a fault condition that does not affect service has occurred. A corrective action is required to prevent a more serious fault such as a service-affecting fault. Such a severity can be reported when the detected alarm condition does not currently degrade the MO capacity. This severity requires an action at a suitable time, or at least that a close observation of the situation continues.

Warning (6)

Indicates that a potential or impending fault affects service, before any significant effects have appeared. Corrective action is based on a scheduled maintenance basis.

2   Basic Fault Management Procedures

3   Advanced Fault Management Concepts

3.1   SNMP Target

An SNMP Target defines information about where and how to send an SNMP Notification. This consists of destination information and SNMP parameters.

4   Advanced Fault Management Procedures