1 Introduction
This instruction concerns alarm handling.
1.1 Alarm Description
The threshold alarm CSCF Charging Answers Indicate Permanent Failures is issued when it is not possible to send one or more Accounting Requests (ACRs) from the CSCF to the charging system.
The alarm is associated to the Performance Management counter cscfACAPermanentFailure.
The alarm is raised when the number of Accounting-Answer (ACA) with permanent errors (code 5xxx) or limited success (code 2002) received through Diameter has reached or exceeded its configured thresholdHigh within the time period configured by thresholdRateOfVariation and granularityPeriod.
The alarm is automatically ceased when it reaches or goes below the configured thresholdLow value.
The default values related to this alarm are thresholdRateOfVariation=PER_GP, granularityPeriod=FIVE_MIN, thresholdHigh=2, and thresholdLow=0. This means that when the counter value is 2 or higher, the alarm is raised when the granularity period is ended. The alarm is ceased when the counter cscfACAPermanentFailure has reached a value of 0 at the end of a granularity period.
- Note:
- The thresholds for raising and ceasing this alarm are configurable.
The default distinguished name for the thresholds is ManagedElement=<node_name>, SystemFunctions=1, Pm=1,
PmJob=CscfChargingStatisticsThreshold, MeasurementReader=cscfACAPermanentFailureMeasReader,
PmThresholdMonitoring=cscfACAPermanentFailure.
It is not possible to change threshold values once they have been set. To change a threshold, first the PmThresholdMonitoring instance must be deleted and recreated with required thresholdHigh and thresholdLow.
For more information, refer to Performance Management.
The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
The PM counter cscfACAPermanentFailure has reached or exceeded its configured upper threshold value. |
The number of received ACA with Result-Code 5xxx (permanent errors) or 2002 (limited success) for sent ACR has reached or exceeded the configured threshold. |
Peer entity problems to interpret or manage ACR messages. |
Peer entity Charging Data Function (CDF) or protocol compatibilities problems between CSCF and CDF. |
Charging information is buffered on persistent media until communication to CDF is re-established. |
- Note:
- An alarm can appear as a result of maintenance activity.
The following is the consequence for the node if the alarm is not solved:
- There is a limited amount of memory reserved (in the range of a few days) to store the charging information temporarily. When this buffer is full, subsequent charging information is lost, and the alarm CSCF Charging Backup File System Unavailable is also raised.
The alarm attributes are shown in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
6684680 |
|
Managed Object Class |
MeasurementReader |
|
Managed Object Instance |
ManagedElement=<node_name>,SystemFunctions=1, Pm=1, PmJob=CscfChargingStatisticsThreshold, MeasurementReader=cscfACAPermanentFailureMeasReader |
|
Specific Problem |
CSCF Charging Answers Indicate Permanent Failures. |
|
Event Type |
communication (2) |
|
Probable Cause |
x733ThresholdCrossed (351) |
|
Additional Text |
cscfACAPermanentFailure between the CSCF and the Charging System |
|
Perceived Severity |
major (4) |
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
This instruction references the following documents:
1.2.2 Tools
Before starting this procedure, ensure that the following tools are available:
- A Diameter protocol sniffer, refer to RFC 3588 Diameter Base Protocol
1.2.3 Conditions
No conditions.
2 Procedure
- Note:
- If the reason for the alarm has disappeared after the granularity period, the alarm automatically ceases.
Do the following:
- Log on and check that the System Controller (SC) is the
primary processor:
cat/proc/drdb
Primary printout: 0:cs:Connected st:Primary/Secondary id:Consistent
or
Secondary printout: 0:cs:Connected st:Secondary/Primary id:Consistent
- Check the log file and grep on error 5xxx
(permanent failures):
grep “Result-Code= [50” /storage/no-backup/cdclsv/log/lpmsv/*
- If no, or too few, 5xxx errors are found, check also for
error 2002 (limited success):
grep “Result-Code= [2002” /storage/no-backup/cdclsv/log/lpmsv/*
- Log off the SC.
- Verify that the alarm is matching with the errors in the log.
- Investigate why communication with the Charging Data Function node fails.
- If the cause is that the alarm threshold is set too low, adjust the alarm threshold.
- Confirm that the alarm has ceased. If the alarm remains, consult the next level of maintenance support and send the extracted information with result-code. Further actions are outside the scope of this instruction.
- Job is completed.