| Managed Object Model 1035/155 54-LZN 768 0145/3-V1 Uen D |
|
|
| Name | Value |
|---|---|
| fmAlarmModelId | IpworksEnum |
| Name | Value |
|---|---|
| additionalText | This alarm is raised when CUDB %s fails during the access. |
| defaultSeverity | WARNING |
| eventType | COMMUNICATIONSALARM |
| fmAlarmTypeId | ipworksEnumCUDBNodeFailure |
| isStateful | true |
| majorType | 193 |
| minorType | 856110 |
| moClasses | IpworksEnum |
| probableCause | 342 |
| specificProblem | ENUM, CUDB Node Failure |
| Name | Value |
|---|---|
| additionalText | This alarm is raised when CUDB %s fails during the access. |
| defaultSeverity | MAJOR |
| eventType | COMMUNICATIONSALARM |
| fmAlarmTypeId | ipworksEnumCUDBSiteFailure |
| isStateful | true |
| majorType | 193 |
| minorType | 856111 |
| moClasses | IpworksEnum |
| probableCause | 342 |
| specificProblem | ENUM, CUDB Site Failure |
| Name | Value |
|---|---|
| additionalText | All the NDB connections are down. DNS ENUM requests that trigger NDB queries will fail with SERVFAIL response. |
| defaultSeverity | CRITICAL |
| eventType | COMMUNICATIONSALARM |
| fmAlarmTypeId | ipworksEnumLostConnDB |
| isStateful | true |
| majorType | 193 |
| minorType | 856067 |
| moClasses | IpworksEnum |
| probableCause | 306 |
| specificProblem | ENUM, Server Lost Connections of DB |
| Name | Value |
|---|---|
| additionalText | The server was unable to start because the initialization process encountered a non-recoverable error. |
| defaultSeverity | CRITICAL |
| eventType | PROCESSINGERRORALARM |
| fmAlarmTypeId | ipworksEnumServFatalError |
| isStateful | true |
| majorType | 193 |
| minorType | 856065 |
| moClasses | IpworksEnum |
| probableCause | 307 |
| specificProblem | ENUM, Server Failed to Start |
| Name | Value |
|---|---|
| additionalText | This alarm is raised when all CUDB connections fail during the access by FE Sync. |
| defaultSeverity | MAJOR |
| eventType | COMMUNICATIONSALARM |
| fmAlarmTypeId | ipworksFESyncCUDBFailure |
| isStateful | true |
| majorType | 193 |
| minorType | 856112 |
| moClasses | IpworksEnum |
| probableCause | 342 |
| specificProblem | ENUM FE Sync, All CUDB Connections Failure |
| Name | Value |
|---|---|
| additionalText | All the NDB connections are down. |
| defaultSeverity | MAJOR |
| eventType | COMMUNICATIONSALARM |
| fmAlarmTypeId | ipworksFESyncLostConnDB |
| isStateful | true |
| majorType | 193 |
| minorType | 856109 |
| moClasses | IpworksEnum |
| probableCause | 306 |
| specificProblem | ENUM FE Sync, Server Lost Connections of DB |