Instances in

Management Information Base

IpworksEnumMomIpworksEnumFmInstances



ManagedElement=1
    +-SystemFunctions=1
        +-Fm=1
            +-FmAlarmModel=IpworksEnum
NameValue
fmAlarmModelIdIpworksEnum

                +-FmAlarmType=ipworksEnumCUDBNodeFailure
NameValue
additionalTextThis alarm is raised when CUDB %s fails during the access.
defaultSeverityWARNING
eventTypeCOMMUNICATIONSALARM
fmAlarmTypeIdipworksEnumCUDBNodeFailure
isStatefultrue
majorType193
minorType856110
moClassesIpworksEnum
probableCause342
specificProblemENUM, CUDB Node Failure

                +-FmAlarmType=ipworksEnumCUDBSiteFailure
NameValue
additionalTextThis alarm is raised when CUDB %s fails during the access.
defaultSeverityMAJOR
eventTypeCOMMUNICATIONSALARM
fmAlarmTypeIdipworksEnumCUDBSiteFailure
isStatefultrue
majorType193
minorType856111
moClassesIpworksEnum
probableCause342
specificProblemENUM, CUDB Site Failure

                +-FmAlarmType=ipworksEnumLostConnDB
NameValue
additionalTextAll the NDB connections are down. DNS ENUM requests that trigger NDB queries will fail with SERVFAIL response.
defaultSeverityCRITICAL
eventTypeCOMMUNICATIONSALARM
fmAlarmTypeIdipworksEnumLostConnDB
isStatefultrue
majorType193
minorType856067
moClassesIpworksEnum
probableCause306
specificProblemENUM, Server Lost Connections of DB

                +-FmAlarmType=ipworksEnumServFatalError
NameValue
additionalTextThe server was unable to start because the initialization process encountered a non-recoverable error.
defaultSeverityCRITICAL
eventTypePROCESSINGERRORALARM
fmAlarmTypeIdipworksEnumServFatalError
isStatefultrue
majorType193
minorType856065
moClassesIpworksEnum
probableCause307
specificProblemENUM, Server Failed to Start

                +-FmAlarmType=ipworksFESyncCUDBFailure
NameValue
additionalTextThis alarm is raised when all CUDB connections fail during the access by FE Sync.
defaultSeverityMAJOR
eventTypeCOMMUNICATIONSALARM
fmAlarmTypeIdipworksFESyncCUDBFailure
isStatefultrue
majorType193
minorType856112
moClassesIpworksEnum
probableCause342
specificProblemENUM FE Sync, All CUDB Connections Failure

                +-FmAlarmType=ipworksFESyncLostConnDB
NameValue
additionalTextAll the NDB connections are down.
defaultSeverityMAJOR
eventTypeCOMMUNICATIONSALARM
fmAlarmTypeIdipworksFESyncLostConnDB
isStatefultrue
majorType193
minorType856109
moClassesIpworksEnum
probableCause306
specificProblemENUM FE Sync, Server Lost Connections of DB
  mib IpworksEnumMomIpworksEnumFmInstances