class DiameterStack

ManagedElement
+-IpworksFunction
+-IPWorksAAARoot
+-IPWorksDiameterAAARoot
+-DiameterStack
+-EirDomain [1..1]
+-HssDomain [1..1]
+-OtpdiaRoot [1..1]

Diameter stack configuration

Attributes
string
key
mandatory
noNotification
restricted
diameterStackId
The value component of the RDN.
string
otpdiaControllerDaemonEndpoints = 169.254.100.1:20001,169.254.100.2:20001
A NULL-terminated string containing a comma-separated list of <addr>:<port> (IPv4) or [<addr>]:<port> (IPv6), on which controller daemons are listening for connections from user processes.

To contain the same address and port pairs that are passed with the --daemon-address and --daemon-port options of otpdia(1) when starting controller daemons.
uint32
otpdiaPoolSize = 1 { 1..4294967295 }
The number of threads to be created in each thread pool.
string[0..1]
otpdiaServiceDnEpcServer = otpdiaService=epc_aaa,otpdiaProduct=IPWorksAAA
Dn of OtpdiaService for epc_server
string[0..1]
otpdiaServiceDnEpcSwx
Dn of OtpdiaService for epc_swx
uint32
outgoingRequestTimeout = 2000
The number of milliseconds after which non-reception of an answer message

Unit: 1 millisecond

  class DiameterStack