| 1 | Introduction |
2 | Measurement Report File |
| 2.1 | File Location |
| 2.2 | Filename Format |
| 2.3 | Time Format |
| 2.4 | File Format |
3 | Supported XML Elements and Attributes |
4 | Example File |
5 | Example File in UTC Format |
1 Introduction
This document describes the 3GPP® compliant Performance Management (PM) XML file format supported in the PM interfaces.
For information on supported functions, concepts, and types of operation, refer to Performance Management.
2 Measurement Report File
A report file contains results of measurements collected from a single Managed Element (ME) during a single Granularity Period (GP) by all active measurement jobs.
The PM report file format is according to 3GPP TS 32.432 type A and is built on the example in 3GPP TS 32.435 Annex A.2. In addition, multi-value counters, also known as Probability Density Function (PDF) measurements, are supported but are not part of the 3GPP specification.
Job grouping is supported. This is indicated by attribute jobGroupingSupport, which default to true.
Report Output Period (ROP) files are written as follows:
- If attribute jobGroup is present, a separate report file is generated containing all measurements for each PM job containing this jobGroup. The <UniqueId> part of the filename is appended with " _<jobGroup>".
- If attribute jobGroup is absent, the default behavior is to include the measurement results for all such jobs in a single PM report file per GP, containing the results of those jobs for which no jobGroup tag was assigned.
If a MeasurementType instance (counter) is being measured in more than one PM job, the measurement result is reported separately for each job in a measurement report file.
The generation of PM ROP files in UTC format is supported. MO attributes PmMeasurementCapabilities::producesUtcRopFiles and PmMeasurementCapabilities::ropFilenameTimestamp are set based on tag produceRopFilesInUtcFormat in libcom_pm.cfg. If this tag is set to true, the PM report files are generated in UTC time with no offset. If tag produceRopFilesInUtcFormat is set to false or the tag does not exist, the PM report files are generated in local time with UTC offset.
- Note:
- As a limitation, the value of the reporting period is identical with the value of the GP, as specified in the granularityPeriod attribute value, while the value of attribute reportingPeriod is ignored.
2.1 File Location
The measurement report files are generated in a directory, as specified in attribute fileGroup in Managed Object (MO) PmMeasurementCapabilities.
2.2 Filename Format
The report XML files are compliant with type "A" of 3GPP TS 32.432. That is, the file contains results of measurements collected from a single ME during a single GP. The filename format is as follows:
A<start_date>.<start_time>-<end_time>_<unique_id>
The different parts of the filename are described in Table 1.
|
Filename Format |
Description |
|---|---|
|
start_date |
Coordinated Universal Time (UTC) date when the GP began. Format: <YYYYMMDD> |
|
start_time |
Format: <HHMMshhmm>, where:
|
|
end_time |
Same format as start_time |
|
unique_id |
Unique name of the ME. This is appended by the value of attribute jobGroup if this attribute is set. |
In Example 1, the GP ended 2014-09-01 at 09:00 in New York (EDT). This is 4 hours behind the UTC. The ME name is NewYork.
In Example 2, the GP ended 2014-09-01 at 11:55 in Stockholm. This is 1 hour ahead of the UTC. The ME name is Stockholm.
In Example 3, the GP ended 2014-09-01 at 11:55 in London. This is 1 hour ahead of the UTC. The ME name is London. The jobGroup for jobs included in this file is set to exampleJobGroup.
In Example 4, the GP ended 2014-09-01 at 11:55 in Paris. This is 2 hour ahead of the UTC. The ME name is Paris. The timestamp of the ROP filename is expressed in UTC time without offset, as attribute producesUtcRopFiles is set to true.
ROP files are compressed if attribute compressionType is set. Only zip compression format is supported, that is, compressionType=GZIP. Gzip compressed ROP files have extension " .xml.gz", as shown in Example 5. The ME name is Berlin.
2.3 Time Format
Times in the measurement result files are expressed in local time. The time format is as follows:
<YYYYMMDDhhmmss.sTZ>
The time format is described in Table 2.
|
Time Format |
Description |
|---|---|
|
YYYY |
Four-digit year |
|
MM |
Two-digit month (01–12) |
|
DD |
Two-digit day of month (01–31) |
|
hh |
Two-digit hour (00–23) |
|
mm |
Two-digit minute (00–59) |
|
ss.s |
Two-digit second (00–59) and one digit representing the decimal fraction of a second |
|
TZ |
Time zone designator Format: +<hhmm> or -<hhmm> |
Example 6 Time Value
20140901221510.1+0200 |
If attribute alignedReportingPeriod is set to true, then the GP and reporting period are aligned to whole minutes. Measurement results are reported at 10:00, 10:10, 10:20, and so on, if the GP is 10 minutes.
2.4 File Format
The measurement report file is based on 3GPP TS 32.435 v10.0.0, PM XML File Format Definition.
Multi-value counters are supported. These are not defined by the 3GPP specifications. Thus, measurement reports files containing multi-value counters are not compliant with the 3GPP XML schema specification.
By the measCollec.xsd schema, the standard defines the structure, name, and number of XML elements allowed in the XML file, see Figure 1 (optional elements are indicated with dotted lines).
For details on support for the elements, see Section 3 Supported XML Elements and Attributes.
For examples of a measurement report file, see Section 4 Example File and Section 5 Example File in UTC Format.
3 Supported XML Elements and Attributes
The root element is measCollecFile.
The supported XML elements and attributes are described in Table 3, Table 4, and Table 5.
|
XML Element or Attribute |
Description |
|---|---|
|
beginTime |
Start time of the measurement data collection. Example: 2014-05-17T20:25:00-02:00 |
|
dnPrefix |
Distinguished Name (DN) prefix, as specified in attribute dnPrefix. Element dnPrefix is present in the report file if attribute dnPrefix is specified, that is, not an empty string. Example: DC=ericsson.se,g3SubNetwork=Sweden |
|
elementType |
Attribute swVersion in MO SwVersionMain is compiled from MO SwItem referenced by attribute active in MO SwInventory as follows: swVersion = " SwItem:administrativeData:productNumber" + " SwItem:administrativeData:productRevision" Example: R7A |
|
fileFormatVersion |
Format version identifier, that is, 32.435 V10.0 |
|
fileHeader |
Root element of the file header |
|
localDn |
Local Distinguished Name (LDN) of ManagedElement. Example: ManagedElement=Stockholm |
|
vendorName |
|
XML Element or Attribute |
Description |
|---|---|
|
duration in granPeriod |
GP in the format PT<n>S, where n denotes seconds and can be 10, 30, 60, 300, 900, 1800, 3600, 43200, or 86400. Element duration can have value Unknown Time , which refers to an internal error. This value is specified by attribute granularityPeriod. Example: PT300S The PM functionality does not support creation of reports for jobs with a GP lower than 60 (that is, 10 or 30) even though these are possible values for a GP according to attribute granularityPeriod. |
|
duration in repPeriod |
Reporting period in the format PT<n>S, where n denotes seconds and can be 10, 30, 60, 300, 900, 1800, 3600, 43200, or 86400. Element duration can have value Unknown Time, which refers to an internal error. This value is specified by attribute reportingPeriod. Example: PT60S |
|
endTime in granPeriod |
End time of the GP. Example: 2010-05-17T20:30:00-02:00 |
|
granPeriod |
Container for elements duration and endTime. Example: PT300S |
|
jobId |
Identifier of the measurement job, as specified in attribute pmJobId. Example: 42 |
|
localDn |
LDN of ManagedElement. Example: ManagedElement=Stockholm |
|
managedElement |
Container for the optional elements localDn, userLabel, and swVersion. |
|
measData |
Root element of the measurement data. |
|
measInfo |
Root element of the measurement information. |
|
measInfoId |
LDN of MO PmGroup to which these measurement types belong. Example: Pm=1,PmGroup=EDchResourcesPmGroup |
|
measObjLdn |
LDN of the measured object. Example: RncFunction=RF-1,UtranCell=Gbg-45 |
|
measType |
Name of the measurement type, as specified in attribute measurementName in MO MeasurementType. Example: counter5 |
|
measValue |
Container element for the measured values. If no measurement value is available, it is an empty element (<measValue/>). |
|
p |
Positioning element connecting the measurement type and value. |
|
r |
Measurement result as a decimal number in one of the following formats:
Element r is NIL when no measurement data is available for Discrete Event Registration (DER) measurement types. For other measurement types, element r is present only if measurement data is available for the measured object in the GP. |
|
repPeriod |
Optional container for element duration. |
|
suspect |
Optional element. Value true indicates that the measurement result is suspected to be incomplete because of an internal error. |
|
swVersion |
Software version, as specified by the concatenation of structure members productNumber and productRevision in attribute administrativeData in MO SwItem referenced by attribute active in MO SwInventory. Element swVersion is present in the report file if structure members productNumber and productRevision are specified, that is, not an empty string. Example: R7A |
|
userLabel |
User-defined label, as specified in attribute userLabel of ManagedElement. Element userLabel is present in the report file if attribute userLabel is specified, that is, not an empty string. |
|
XML Element or Attribute |
Description |
|---|---|
|
endTime |
End time of the measurement data collection. Example: 2012-09-28T20:30:00-02:00 |
|
fileFooter |
Root element of the file footer. |
- Note:
- XML element measResults is not supported.
4 Example File
A measurement report file valid for the XML schema is shown in Example 7.
Example 7 Measurement Report File
<?xml version="1.0" encoding="UTF-8"?> <?xml-stylesheet type="text/xsl" href="MeasDataCollection.xsl"?> <measCollecFile xmlns="http://www.3gpp.org/ftp/specs/archive/32_series/32.435#measCollec"> <fileHeader fileFormatVersion="32.435 V10.0" vendorName="Ericsson" dnPrefix="localDnString"> <fileSender localDn="ManagedElement=Stockholm" elementType="RNC"/> <measCollec beginTime="2012-09-13T09:05:00Z"/> </fileHeader> <measData> <managedElement localDn="ManagedElement=Stockholm" swVersion="3.0"/> <measInfo measInfoId=”Pm=1,PmGroup=EDchResourcesPmGroup”> <job jobId="18"/> <granPeriod duration="PT300S" endTime="2012-09-13T09:10:00Z"/> <repPeriod duration="PT300S"/> <measType p="1">counter0</measType> <measType p="2">counter1</measType> <measType p="3">counter2</measType> <measType p="4">counter3</measType> <measType p="5">DERcounter</measType> <measValue measObjLdn="RncFunction=RF-1,UtranCell=Gbg-74"> <r p="1">1112085071</r> <r p="2">2146690188</r> <r p="3">-1172923322</r> <r p="4">0.993486918695812</r> <r p="5">NIL</r> </measValue> <measValue measObjLdn="RncFunction=RF-1,UtranCell=Gbg-75"> <r p="1">-2127992685</r> <r p="2">-1224586944</r> <r p="3">208233284</r> <r p="4">0.054777712404499</r> <r p="5">3412678214</r> <suspect>true</suspect> </measValue> <measValue measObjLdn="RncFunction=RF-1,UtranCell=Gbg-80"> <r p="1">-267379297</r> <r p="2">846868841</r> <r p="3">1985356161</r> <r p="4">-0.117524608953742</r> <r p="5">NIL</r> </measValue> </measInfo> <measInfo measInfoId=”Pm=1,PmGroup=EDchResourcesPmGroup”> <job jobId="5"/> <granPeriod duration="PT300S" endTime="2012-09-13T09:10:00Z"/> <repPeriod duration="PT300S"/> <measType p="1">gauge0</measType> <measType p="2">gauge1</measType> <measValue measObjLdn="RncFunction=RF-1,UtranCell=Gbg-74"> <r p="1">-1571763234</r> <r p="2">318908185</r> </measValue> <measValue measObjLdn="RncFunction=RF-1,UtranCell=Gbg-75"> <r p="1">-1727546023</r> <r p="2">77341715</r> </measValue> <measValue measObjLdn="RncFunction=RF-1,UtranCell=Gbg-100"> <r p="1">1254950829</r> <r p="2">-447563054</r> </measValue> </measInfo> |
<measInfo measInfoId=”Pm=1,PmGroup=EDchResourcesPmGroup”>
<job jobId="23"/>
<granPeriod duration="PT300S" endTime="2012-09-13T09:10:00Z"/>
<repPeriod duration="PT300S"/>
<measType p="1">pdf0</measType>
<measType p="2">pdf1</measType>
<measValue measObjLdn="RncFunction=RF-1,UtranCell=Gbg-74">
<r p="1">-1.578,1.84,279,3.185</r>
<r p="2">6794,7300,6901,7143,7297</r>
</measValue>
<measValue measObjLdn="RncFunction=RF-1,UtranCell=Gbg-75">
<r p="1">6.894,7.142,6.901,7.009</r>
<r p="2">8852,8309,9111,8934,7993</r>
</measValue>
<measValue measObjLdn="RncFunction=RF-1,UtranCell=Gbg-100">
<r p="1">4.657,5.478,4.912,5.111</r>
<r p="2">6345,6546,6901,6789,6698</r>
</measValue>
</measInfo>
</measData>
<fileFooter>
<measCollec endTime="2012-09-13T09:10:00Z"/>
</fileFooter>
</measCollecFile>
|
5 Example File in UTC Format
A measurement report file in UTC format is shown in Example 8.
Example 8 Measurement Report File in UTC Format
<?xml version="1.0" encoding="UTF-8"?> <?xml-stylesheet type="text/xsl" href="MeasDataCollection.xsl"?> <measCollecFile xmlns="http://www.3gpp.org/ftp/specs/archive/32_series/32.435#measCollec"> <fileHeader fileFormatVersion="32.435 V10.0" vendorName="Ericsson AB"> <fileSender localDn="ManagedElement=1" elementType="ERIC-COREMW_RUNTIME"/> <measCollec beginTime="2015-06-15T11:06:00"/> </fileHeader> <measData> <managedElement localDn="ManagedElement=1" swVersion="CXP9020355_1 R6M01"/> <measInfo measInfoId="CcGroupMR1"> <job jobId="job_one_min"/> <granPeriod duration="PT60S" endTime="2015-06-15T11:07:00"/> <repPeriod duration="PT60S"/> <measType p="1">CcMR-1</measType> <measValue measObjLdn="counter2"> <r p="1">11505</r> <suspect>true</suspect> </measValue> </measInfo> </measData> <fileFooter> <measCollec endTime="2015-06-15T11:07:00"/> </fileFooter> </measCollecFile> |

Contents