| Attributes |
uint8[0..1] |
-
ainQualityOfService
=
3
{
0..3
}
-
The Quality of Service (QoS) provides IPWorks with the ability to indicate the acceptable quality of the service provided by the underlying layers. The values can be 0, 1, 2 and 3. 0 means Quality of service not used. 1 means In-sequence delivery option. 2 means Message return option. 3 means Both in-sequence delivery and message return options. The default value is 3.
Take effect: After ENUM server is restarted.
|
CpInstanceId |
-
cpInstanceId
=
PL-3:1|PL-4:2
-
The instance ID of CP manager on the board where ERH deployed.
If enableHA is true, the instance ID should be difference on each board.
Take effect: After ENUM server is restarted.
Obsolete:
|
string |
-
cpManager
=
ss7cafcpmaddress:6669
-
The SS7 MIP address and port number of SS7 CP manager.
Take effect: After ENUM server is restarted.
|
string[0..1] |
-
cpManagerPeerHost
=
127.0.0.1:6669
-
The address and port number of peer SS7 CP manager.
If enableHA is true, this parameter should indicate the address and port of peer SS7 CP manager.
Take effect: After ENUM server is restarted.
Obsolete:
|
boolean |
-
enableCustomizedDigTable
=
false
-
Determines whether to use customized digit table.
Take effect: After ENUM server is restarted.
|
boolean |
-
enableHA
=
true
-
If redundancy mode is required, then the stack must be configured as HA mode. Therefore, this attribute must be set to true.
Take effect: After ENUM server is restarted.
Obsolete:
|
string key mandatory noNotification restricted |
-
erhSs7Id
-
The value component of the RDN.
|
boolean |
-
formatFlag
=
false
-
To customize routing number format for INAP.
Take effect: After ENUM server is restarted.
|
ApplicationContexTypeEnum |
-
inapApplicationContexType
=
CS1
-
The Application context Type that INAP uses. The value can be either CS1 or CS1PLUS.
The default value is CS1.
Take effect: After ENUM server is restarted.
|
DigitTable |
-
inapDigitTable
=
0x0=0,0x1=1,0x2=2,0x3=3,0x4=4,0x5=5,0x6=6,0x7=7,0x8=8,0x9=9,0xA= ,0xB=b,0xC=c,0xD= ,0xE=
-
Digit table of INAP.
Take effect: After ENUM server is restarted.
|
boolean |
-
inapFilterRNOfDestRoutingAddr
=
false
-
Filter RN from DestRoutingAddr, cut 15 digits to 6 digits for INAP.
Take effect: After ENUM server is restarted.
|
InterrogationType[0..1] |
-
InterrogationType
=
BASIC
-
Indicates the type of interrogation of SRI message.
|
string |
-
logFileName
=
ipwerh.log
-
Specifies the log file name for ERH over SS7 featrue.
Take effect: After ENUM server is restarted.
|
DigitTable |
-
mapDigitTable
=
0x0=0,0x1=1,0x2=2,0x3=3,0x4=4,0x5=5,0x6=6,0x7=7,0x8=8,0x9=9,0xA=*,0xB=#,0xC=a,0xD=b,0xE=c
-
Digit table of MAP.
Take effect: After ENUM server is restarted.
|
MAPOperationType[0..1] |
-
MAPMessage
=
MAP_ATI
-
Defines IPWorks ENUM NP support MAP operation type, SRI and ATI.
|
Mcc3bitMncPair |
-
mcc3bitMNCPAIR
=
302-656|374-130|374-140|714-020
-
All MCC-MNC pair, and MNC is 3 bit. IPWorks ERH only support to confiugre less than 30 MCC-MNC pair.
Take effect: After ENUM server is restarted.
|
MccWith3bitMnc |
-
mccWith3bitMNC
=
310|311|316|334|338|342|344|346|348|365|376|708|722|732|750
-
All MCC which only have 3 bit MNC. IPWorks ERH only support to confiugre less than 30 MNC.
Take effect: After ENUM server is restarted.
|
MSRNMode[0..1] |
-
MSRNMode
=
NOFURTHERHANDLING
-
Indication of the mode used to handle MSRN returned from NPDB before sending it to ENUM.
|
int32 |
-
numOfBindBEs
=
10
{
1..10
}
-
The max number of BEs that ERH can bind to.
Take effect: After ENUM server is restarted.
|
int32 |
-
numOfErh
=
10
{
1..10
}
-
In scalable configuration, the max number of Erh that system can support.
Take effect: After ENUM server is restarted.
|
int32[0..1] |
-
remoteSSN
=
0
{
0..255
}
-
ERH remote SSN.
Take effect: After ENUM server is restarted.
|
ReturnWholeMSRN[0..1] |
-
returnWholeMSRN
=
RNONLY
-
Defines whether to return whole MSRN string or RN only.
|
uint32[0..1] |
-
RNLength
=
4
-
Length of RN in MSRN string.
|