class AcctFinder

ManagedElement
+-IpworksFunction
+-IPWorksAAARoot
+-IPWorksRadiusAAARoot
+-RadiusAAAService
+-AccountingService
+-AcctFinder

This is Managed Object Class for Accounting Finder.

Attributes
string
key
mandatory
noNotification
restricted
acctFinderId
The value component of the RDN.
uint16
finderBatchCount = 3000
Specifies the accouting finder batch count, ipworks finder batch records number is limited to count. The default value is 3000.

Takes effect: After next restart
uint16
finderInterval = 15
Specifies the accounting finder check interval.

The default value is 15 seconds.


Unit: 1 second
Takes effect: After next restart
uint16
finderStopTimeDelta = 5
Specifies the accounting finder stop time delta, IPWorks capture the accounting record that the last update time is less than current time minus delta time.

The default value is 5 minutes.


Unit: 1 minute
Takes effect: After next restart

  class AcctFinder