| Attributes |
string |
-
cpmAddress
=
ss7cafcpmaddress:6669
-
Specifies the CP management address of SS7 stack. The format is IP: port, separated by comma. The setting must be the same as that of CP Manager Address of the SS7 stack. In the SS7 signalling Manager, the value can be found at System Components > System Components.
Takes effect: After next restart
|
string |
-
isdnNumber
=
123456
[
1..16
]
-
Assigns the number of ISDN for IPWorks AAA Server.
Takes effect: After next restart Valid values: [0-9]+
|
ISDNNOA |
-
isdnNumberNature
=
NOA_NATIONAL_SIGNIFICANT
-
Specifies the nature of ISDN.
The default value is NOA_NATIONAL_SIGNIFICANT.
Takes effect: After next restart
|
uint8 |
-
nodeType
=
1
{
0..1
}
-
Specifies AAA Node Type:
0: D' interface
1: Gr' interface (default)
Takes effect: After next restart
|
uint16 |
-
numberOfAAAProcess
=
10
-
Specifies the number of AAA process.
The default value is 10.
Takes effect: After next restart
|
uint8 |
-
numberOfBEInstance
=
10
{
1..16
}
-
Specifies the number of BE instance.
The default value is 10.
Takes effect: After next restart
|
uint32 |
-
originalSignalingPointCode
=
100
{
0..16777215
}
-
Specifies the original SPC of SS7. The range is from 0 to 16777215.
Takes effect: After next restart
|
string key mandatory noNotification restricted |
-
radiusSs7StackId
-
The value component of the RDN.
|
Ipv4Ipv6 |
-
sgsnAddress
=
127.0.0.1
-
Specifies the IP address of SGSN.
Takes effect: After next restart
|
boolean |
-
useGT4CallingPartyAddress
=
false
-
If the value is true, IPWorks will encode GT into the calling party address and sets the routing indicator to route on GT.
The default value is false.
Takes effect: After next restart
|