Check Alarm Status

Contents

1Introduction
1.1Prerequisites

2

Procedure

1   Introduction

This document describes how to check the alarm status. The alarm status can be checked as part of preventive maintenance or problem resolution activities. In such situations, a detailed view of the active alarms in the managed element is required.

1.1   Prerequisites

This section describes the prerequisites, which must be fulfilled before using the procedure.

1.1.1   Conditions

The following condition must apply:

2   Procedure

To check the alarm status:

  1. Navigate to the Fm managed object, for example:

    >dn ManagedElement=NODE06ST,SystemFunctions=1,Fm=1

  2. Show the alarm list:

    (Fm=1)>show

  3. Show the details of an alarm, for example:

    (Fm=1)>show FmAlarm=1

    The following is an example output:

    FmAlarm=1
       activeSeverity=minor
       additionalInfo=""
       additionalText="Time servers not reachable"
       eventType=6
       lastEventTime="2015-03-30T10:54:35+00:00"
       majorType=193
       minorType=3341942785
       originalAdditionalText="Time servers not reachable"
       originalEventTime="2015-03-30T10:54:35+00:00"
       originalSeverity=minor
       probableCause=418
       sequenceNumber=1
       source="ManagedElement=NODE06ST,HostName=SC-1,ERIC-LINUX-CONTROL-⇒
    ANA90139_3-R6A06"
       specificProblem="LOTC Time Synchronization"
  4. Show the detailed alarm status:

    (Fm=1)>show-table -m FmAlarm -p fmAlarmId,source,activeSeverity,specificProblem

    The following is an example output:

    fmAlarmId

    Source

    activeSeverity

    specificProblem

    1

    ManagedElement=NODE06ST,HostName=SC-1,⇒
    ERIC-LINUX-CONTROL-ANA90139_3-R6A06

    minor

    LOTC Time
    Synchronization

    2

    ManagedElement=NODE06ST,SystemFunctions=1,⇒
    Brm=1,BrmBackupManager=SYSTEM_DATA,⇒
    BrmBackupScheduler=SYSTEM_DATA

    major

    BRM, Scheduled Backup Failed

    10

    ManagedElement=NODE06ST,Conn=conn1,⇒
    Stack=CSCFRF,Host=LABSPTOFFCHA2.ericsson.se

    warning

    Diameter, Link Disabled

In addition to the general procedure, you can check the alarm status directly by following command:

SC-1:~ # echo -e ' show-table ManagedElement=1,SystemFunctions=1,Fm=1 -m FmAlarm -p fmAlarmId,source,activeSeverity,specificProblem:40 \t\nexit' | su -c ' /opt/com/bin/cliss -b'

The following is an example output:

fmAlarmId

Source

activeSeverity

specificProblem

1

ManagedEl..._4-R2A11

minor

LOTC Time
Synchronization

2

ManagedEl..._4-R2A11

major

LOTC Time
Synchronization

10

ManagedEl....161.209

warning

ENUM, CUDB Node Failure

11

ManagedEl...te=site1

minor

ENUM, CUDB Node Failure

12

ManagedEl...umFESync

minor

ENUM FE Sync, All C...onnections Failure

13

ManagedEl...68.218.1

minor

eVIP, Gateway Unavailable

14

ManagedEl...:0:31::2

minor

eVIP, Gateway Unavailable

15

ManagedEl...68.218.2

minor

eVIP, Gateway Unavailable