List Performance Management Groups and Measurement Types

Contents

1Introduction
1.1Prerequisites

2

Procedure

1   Introduction

This document describes how to list the Performance Management (PM) groups and measurement types. The list of PM groups and measurement types informs the user about what measurement data it is possible to collect on the managed element.

1.1   Prerequisites

This section describes the prerequisites, which must be fulfilled before using the procedure.

1.1.1   Conditions

The following condition must apply:

2   Procedure

To list the PM groups and measurement types:

  1. Navigate to the Pm Managed Object (MO), for example:

    >dn ManagedElement=NODE06ST,SystemFunctions=1,Pm=1

  2. List the PM groups:

    (Pm=1)>show –m PmGroup

    The following is an example output:

PmGroup=DbsPOT
   category="Feature DbsFunction, Class DbsPOT"
   consistentData=true
   description="POT measurement types"
   generation="IMS"
   switchingTechnology="Packet Switched"
   validity=true
   moClass
      mimName="DbsPOT_PmMim"
      mimRelease="1"
      mimVersion="1"
      moClassName="DbsPOT"
PmGroup=DbsPU
   category="Feature DbsFunction, Class DbsPU"
   consistentData=true
   description="PU measurement types"
   generation="IMS"
   switchingTechnology="Packet Switched"
   validity=true
   moClass
      mimName="DbsPU_PmMim"
      mimRelease="1"
      mimVersion="1"
      moClassName="DbsPU"
PmGroup=DbsVM
   category="Feature DbsFunction, Class DbsVM"
   consistentData=true
   description="VM measurement types"
   generation="IMS"
   switchingTechnology="Packet Switched"
   validity=true
   moClass
      mimName="DbsVM_PmMim"
      mimRelease="1"
      mimVersion="1"
      moClassName="DbsVM"
Note:  
The value of attribute moClassName contains the name of a class in the model to which the PM group is applicable.

  1. Navigate to a PmGroup MO, for example:

    (Pm=1)>PmGroup=DbsPOT

  2. List the measurement types for the PM group:

    (PmGroup=DbsPOT)>show -v -r

    The following is an example output for a PM group consisting of three measurement types:

PmGroup=DbsPOT
   category="Feature DbsFunction, Class DbsPOT" <read-only>
   consistentData=true <read-only>
   description="POT measurement types" <read-only>
   generation="IMS" <read-only>
   pmGroupId="DbsPOT"
   switchingTechnology="Packet Switched" <read-only>
   validity=true <read-only>
   moClass <read-only>
      mimName="DbsPOT_PmMim" <read-only>
      mimRelease="1" <read-only>
      mimVersion="1" <read-only>
      moClassName="DbsPOT" <read-only>
   MeasurementType=PotInst.Count
      aggregation=MAX <read-only>
      collectionMethod=GAUGE <read-only>
      condition="The actual number of instances for a keyed or non-keyed POT instances." ⇒
<read-only>
      derSampleRate=[] <empty>
      description="Measures the total number of instances for a keyed or non-keyed POT in a ⇒
GP." <read-only>
      fmAlarmType=[] <empty>
      initialValue=0 <read-only>
      measurementName="DbsPotPotInstCount" <read-only>
      measurementResult=[] <empty>
      measurementStatus=USED <read-only>
      measurementTypeId="PotInst.Count"
      multiplicity=1 <read-only>
      resetAtGranPeriod=true <read-only>
      size=10 <read-only>
      thresholdDirection=INCREASING <default> <read-only>
   MeasurementType=PotInst.Create
      aggregation=SUM <read-only>
      collectionMethod=CC <read-only>
      condition="The counter is incremented when a keyed or a non-keyed POT instance created." ⇒
<read-only>
      derSampleRate=[] <empty>
      description="Measures the number of creates issued for a keyed or non-keyed POT in a GP." ⇒
<read-only>
      fmAlarmType=[] <empty>
      initialValue=0 <read-only>
      measurementName="DbsPotPotInstCreate" <read-only>
      measurementResult=[] <empty>
      measurementStatus=USED <read-only>
      measurementTypeId="PotInst.Create"
      multiplicity=1 <read-only>
      resetAtGranPeriod=true <read-only>
      size=10 <read-only>
      thresholdDirection=INCREASING <default> <read-only>
   MeasurementType=PotInst.Create.Commit
      aggregation=SUM <read-only>
      collectionMethod=CC <read-only>
      condition="The counter is incremented when a keyed or a non-keyed POT  instance creation ⇒
committed." <read-only>
      derSampleRate=[] <empty>
      description="Measures the number of instances created for a keyed or non-keyed POT in a ⇒
GP." <read-only>
      fmAlarmType=[] <empty>
      initialValue=0 <read-only>
      measurementName="DbsPotPotInstCreateCommit" <read-only>
      measurementResult=[] <empty>
      measurementStatus=USED <read-only>
      measurementTypeId="PotInst.Create.Commit"
      multiplicity=1 <read-only>
      resetAtGranPeriod=true <read-only>
      size=10 <read-only>
      thresholdDirection=INCREASING <default> <read-only>
Note:  
fmAlarmType=[] <empty> means that no threshold alarm is supported for this measurement type.



Copyright

© Ericsson AB 2016. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    List Performance Management Groups and Measurement Types