class PmGroup

..
+-SystemFunctions
+-Pm
+-PmGroup
+-MeasurementType [1..]

A grouping of the measurements into logical grouping.
PmGroup is unique in the ME.


This MO is created by the system.

Attributes
string[0..1]
noNotification
readOnly
category
Deprecated, Comma-separated sequence of key words.
Used for categorization and searching for data among reports. e.g. KPI, Feature xx, etc.
Deprecated in ECIM PM 2.2.


Deprecated: There is no practical use for this attribute in the model. It will not be visible in PM report files.

boolean[0..1]
noNotification
readOnly
consistentData
Deprecated, Defines whether or not this group of data is guaranteed to be consistent.
Counter Data Consistency
In some MEs there are both detailed counters, e.g. #failedConnections and #succeededConnections, as well as more high-level summary counters. e.g. #totalConnections.
A counter group is guaranteed to be consistent if it does not contain a summary counter whose value can be calculated based on other counters in that group, or if it does so but this calculation will always show the same value as the summary counter.
Deprecated in ECIM PM 2.2.


Deprecated: There is no practical need for this attribute in the model.

string[0..1]
noNotification
readOnly
description
Description of the PmGroup.
string[0..1]
noNotification
readOnly
generation
Determines if group concerns GSM, UMTS, EPS, combined (GSM+UMTS+EPS) or IMS measurements.
Values are defined in 3GPP standard 32:404.
ManagedObjectClass[0..1]
noNotification
readOnly
moClass
The Managed Object Class that uses the Measurement Types in this PmGroup.
No value means this PM Group is not associated with any specific Managed Object Class.
string
key
mandatory
noNotification
restricted
pmGroupId
Holds the name used when identifying the MO.
string
noNotification
readOnly
pmGroupVersion
PM Group version identifier.
Unique version identifier associated with a change to the contents of the PM Group, where new MeasurementTypes have been added.
string[0..1]
noNotification
readOnly
switchingTechnology
The Switching domain or domains to which this measurement is applicable.
Values are defined in 3GPP standard 32.404.
boolean[0..1]
noNotification
readOnly
validity
States if the group is valid.
A group might not be valid if, for example, the feature that this group is used for is not available to the customer.

  class PmGroup