1 Introduction
This document describes how to start a threshold monitoring job. A threshold monitoring job is started to enable the reporting of threshold alarms for the corresponding measurement types. This is usually done when the managed element is operational and manageable as part of the normal operations.
1.1 Prerequisites
This section describes the prerequisites, which must be fulfilled before using the procedure.
1.1.1 Conditions
The following conditions must apply:
- The job name is known.
The job name is POT_Thr_Job in this document.
- currentJobState for the job is STOPPED.
- An Ericsson Command-Line Interface (ECLI) session in Exec mode is in progress.
2 Procedure
To start a threshold monitoring job:
- Navigate to the PmJob Managed Object (MO), for example:
>dn ManagedElement=NODE06ST,SystemFunctions=1,Pm=1,PmJob=POT_Thr_Job
- Enter Config mode:
(PmJob=POT_Thr_Job)>configure
- Set the PmJob state to ACTIVE:
(config-PmJob=POT_Thr_Job)>requestedJobState=ACTIVE
- Commit the PmJob MO
configuration:
(config-PmJob=POT_Thr_Job)>commit
- Verify the result:
(PmJob=POT_Thr_Job)>show -v
The following is an example output:
PmJob=POT_Thr_Job compressionType=[] <empty> currentJobState=ACTIVE <read-only> granularityPeriod=FIFTEEN_MIN <default> jobControl=FULL <default> <read-only> jobGroup=[] <empty> jobPriority=MEDIUM <default> jobType=THRESHOLDJOB pmJobId="POT_Thr_Job" reportContentGeneration=CHANGED_ONLY <default> reportingPeriod=FIFTEEN_MIN <default> requestedJobState=ACTIVE <default> MeasurementReader=POT_mr
- Note:
- An alarm notification is issued at the end of the reporting period if thresholdHigh in the PmThresholdMonitoring MO has been exceeded.