Diameter AAA, Connection to SS7 Error
IPWorks

Contents

1Introduction
1.1Alarm Description
1.2Prerequisite
1.3Related Information

2

Procedure

Reference List

1   Introduction

This instruction concerns alarm handling.

1.1   Alarm Description

This alarm is raised when the SS7 stack for Diameter AAA is unavailable.

The possible alarm causes and fault locations are explained in Table 1.

Table 1    Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

Solution

SS7 is unavailable

The Diameter AAA cannot connect to SS7 stack, or use the service of the stack.

Incorrect CPM Address or SS7 stack configuration.

AAA Server or SS7

AAA server cannot provide SS7 related service (for example, Wi-Fi Mobility Management).

See Section 2

Note:  
An alarm can appear as a result of the maintenance activity.

The alarm attributes are listed and explained in Table 2.

Table 2    Alarm Attributes

Attribute Name

Attribute Value

Major Type

193

Minor Type

864263

Managed Object Class

IpworksDiameterAAA

Source

ManagedElement=<Node Name>, SystemFunctions=1,Fm=1,FmAlarmModel=ipworksDiameterAAA, FmAlarmType=ipworksDiameterAAAConnectionToSS7Error

Specific Problem

Diameter AAA, Server Cannot Connect to SS7 Stack

Event Type

communicationsAlarm(2)

Probable Cause

x733CommunicationsSubsystemFailure(306)

Additional Text

This alarm is raised when the SS7 stack for Diameter AAA is unavailable.;uuid:<Product_UUID>(1)

Perceived Severity


Warning

Critical

(1)  <Product_UUID> is the universally unique identifier (UUID) of machine that generates the alarm. The value can be fetched from /sys/devices/virtual/dmi/id/product_uuid on the PL node.


1.2   Prerequisite

This section provides information on the documents, tools, and conditions that apply to the procedure.

1.2.1   Documents

Before starting this procedure, ensure that the following document has been read:

1.2.2   Tools

Not Applicable

1.2.3   Conditions

Not Applicable

1.3   Related Information

Trademark information, typographic conventions, and definition and explanation of abbreviations and terminology can be found in the following documents:

2   Procedure

To clear the alarm, do the following:

  1. Check if the CPM Address is correctly configured, normally CPM Address is ss7cafcpmaddress:6669. For information about how to configure CPM Address, refer to Section Configuring Wi-Fi Mobility Management in Configure EPC AAA.
  2. Check if the SS7 stack is correctly configured. For information about how to configure the SS7 stack, refer to Section Configuring SS7 for Wi-Fi MM in Configure SS7 for AAA.

Reference List

Ericsson Documents
[1] Trademark Information.
[2] Typographic Conventions.
[3] Glossary of Terms and Acronyms.
[4] Fault Management.
[5] Configure EPC AAA.
[6] Configure SS7 for AAA.


Copyright

© Ericsson AB 2017, 2018. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    Diameter AAA, Connection to SS7 Error         IPWorks