Diameter AAA, Peer Connection Unreachable
IPWorks

Contents

1Introduction
1.1Alarm Description
1.2Prerequisite
1.3Related Information

2

Procedure
2.1Making the Peer Node Works Normally
2.2Troubleshooting the Network Issues
2.3Actions for Clearing Alarm

Reference List

1   Introduction

This instruction concerns alarm handling.

1.1   Alarm Description

This alarm is issued when all the connection is broken between AAA with one remote peer node. The remote peer node can be HSS , Access Gateway, or PDN Gateway.

The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.

Table 1    Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

Solution

Failed to connect to remote diameter node.

The connection between EPC AAA and remote diameter node is broken.

The remote diameter node is abnormal.

Remote peer node

AAA server cannot provide service.

Section 2.1

The remote diameter node is not reachable.

The network connection or other related issues.

Network

Section 2.2

Note:  
An alarm can appear as a result of the maintenance activity.

The alarm attributes are listed and explained in Table 2.

Table 2    Alarm Attributes

Attribute Name

Attribute Value

Major Type

193

Minor Type

864264

Managed Object Class

IpworksDiameterAAA

Source

ManagedElement=<Node Name>, SystemFunctions=1,F m=1,FmAlarmModel=ipworksDiameterAAA, FmAlarmTy pe= ipworksDiameterAAAPeerConnectionUnreachable

Specific Problem

Diameter AAA, Peer Connection Unreachable

Event Type

communicationsAlarm(10)

Probable Cause

x733RemoteNodeTransmissionError(342)

Additional Text

This alarm is raised when the diameter connection to remote peer %s fails.;uuid:<Product_UUID>(1)

Perceived Severity

Major

(1)  <Product_UUID> is the universally unique identifier (UUID) of machine that generates the alarm. The value can be fetched from /sys/devices/virtual/dmi/id/product_uuid on the PL node.


1.2   Prerequisite

This section provides information on the documents, tools, and conditions that apply to the procedure.

1.2.1   Documents

Before starting this procedure, ensure that the following documents have been read:

1.2.2   Tools

Not available.

1.2.3   Conditions

Not applicable.

1.3   Related Information

Trademark information, typographic conventions, and definition and explanation of abbreviations and terminology can be found in the following documents:

2   Procedure

This section describes the procedure to follow to clear this alarm.

2.1   Making the Peer Node Works Normally

To clear the alarm, do the following:

Note:  
In this section, the Peer Node indicates one of the following nodes:
  • HSS node/relay agent
  • Access Gateway
  • PDN Gateway

  1. Check the alarm attribute Additional Info to get the IP address of remote peer node.

    For example, the message " This alarm is raised when the diameter connection to remote peer 10.170.15.166 fails", which indicates that the IP address of the peer node is 10.170.15.166.

  2. Based on retrieved IP, troubleshoot and solve the issues on the specific peer node.

    The alarm is expected to be cleared automatically if the peer node returns to normal.

  3. The alarm is expected to be cleared automatically if the Peer Node returns to normal.

2.2   Troubleshooting the Network Issues

To clear the alarm, do the following:

  1. Debug and troubleshoot the network issues.

    The alarm is expected to be cleared automatically if the network connection returns to normal.

  2. If the alarm still remains, consult the next level of maintenance support. Further actions are outside the scope of this instruction.

2.3   Actions for Clearing Alarm

When the peer node was disconnected with IPWorks AAA, the alarm needs to be manually cleared.

  1. List the alarms.

    # ipw-alarm --cmd list

    For example, FmAlarm=528

    activeSeverity=MAJOR <read-only>
       additionalText="This alarm is raised when the diameter connection to remote Peer fttools-DRA.dra.ericsson.se@dra.ericsson.se fails." <read-only>
       eventType=COMMUNICATIONSALARM <read-only>
      fmAlarmId="528"
       lastEventTime="2018-03-15T17:16:37.404+08:00" <read-only>
       majorType=193 <read-only>
       minorType=864264 <read-only>
       originalAdditionalText="This alarm is raised when the diameter connection to remote Peer fttools-DRA.dra.ericsson.se@dra.ericsson.se fails." <read-only>
       originalEventTime="2018-03-15T17:16:37.404+08:00" <read-only>
       originalSeverity=MAJOR <read-only>
       probableCause=342 <read-only>
       sequenceNumber=1127 <read-only>
         source="ManagedElement=ipworks_cba,SystemFunctions=1,Fm=1,FmAlarmModel=ipworksDiameterAAA,FmAlarmType=ipworksDiameterAAAPeerConnectionUnreachable,IpworksDiameterAAA,Peer=fttools-DRA.dra.ericsson.se@dra.ericsson.se" <read-only>
       specificProblem="Diameter AAA, Diameter Peer Connection Unreachable" <read-only>
    

  2. Clear the alarm.

    # ipw-alarm --cmd clear --id <Alarm ID>

    The <Alarm ID> can be found in the example output in Step 1.


Reference List

Ericsson Documents
[1] Trademark Information.
[2] Typographic Conventions.
[3] Glossary of Terms and Acronyms.
[4] Fault Management.


Copyright

© Ericsson AB 2017, 2018. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    Diameter AAA, Peer Connection Unreachable         IPWorks