1 Introduction
This instruction concerns alarm handling.
1.1 Alarm Description
This alarm is issued when all the connection is broken between AAA with one remote peer node. The remote peer node can be HSS , Access Gateway, or PDN Gateway.
The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
Solution |
|---|---|---|---|---|---|
|
Failed to connect to remote diameter node. |
The connection between EPC AAA and remote diameter node is broken. |
The remote diameter node is abnormal. |
Remote peer node |
AAA server cannot provide service. |
|
|
The remote diameter node is not reachable. |
The network connection or other related issues. |
Network |
- Note:
- An alarm can appear as a result of the maintenance activity.
The alarm attributes are listed and explained in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
864264 |
|
Managed Object Class |
IpworksDiameterAAA |
|
Source |
ManagedElement=<Node Name>, SystemFunctions=1,F m=1,FmAlarmModel=ipworksDiameterAAA, FmAlarmTy pe= ipworksDiameterAAAPeerConnectionUnreachable |
|
Specific Problem |
Diameter AAA, Peer Connection Unreachable |
|
Event Type |
communicationsAlarm(10) |
|
Probable Cause |
x733RemoteNodeTransmissionError(342) |
|
Additional Text |
This alarm is raised when the diameter connection to remote peer %s fails.;uuid:<Product_UUID>(1) |
|
Perceived Severity |
Major |
(1) <Product_UUID> is the universally
unique identifier (UUID) of machine that generates the alarm. The
value can be fetched from /sys/devices/virtual/dmi/id/product_uuid on the PL node.
1.2 Prerequisite
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
Before starting this procedure, ensure that the following documents have been read:
1.2.2 Tools
Not available.
1.2.3 Conditions
Not applicable.
1.3 Related Information
Trademark information, typographic conventions, and definition and explanation of abbreviations and terminology can be found in the following documents:
2 Procedure
This section describes the procedure to follow to clear this alarm.
2.1 Making the Peer Node Works Normally
To clear the alarm, do the following:
- Note:
- In this section, the Peer Node indicates one of the following nodes:
- Check the alarm attribute Additional Info to get the IP address of remote peer node.
For example, the message " This alarm is raised when the diameter connection to remote peer 10.170.15.166 fails", which indicates that the IP address of the peer node is 10.170.15.166.
- Based on retrieved IP, troubleshoot and solve the issues
on the specific peer node.
The alarm is expected to be cleared automatically if the peer node returns to normal.
- The alarm is expected to be cleared automatically if the Peer Node returns to normal.
2.2 Troubleshooting the Network Issues
To clear the alarm, do the following:
- Debug and troubleshoot the network issues.
The alarm is expected to be cleared automatically if the network connection returns to normal.
- If the alarm still remains, consult the next level of maintenance support. Further actions are outside the scope of this instruction.
2.3 Actions for Clearing Alarm
When the peer node was disconnected with IPWorks AAA, the alarm needs to be manually cleared.
- List the alarms.
# ipw-alarm --cmd list
For example, FmAlarm=528
activeSeverity=MAJOR <read-only> additionalText="This alarm is raised when the diameter connection to remote Peer fttools-DRA.dra.ericsson.se@dra.ericsson.se fails." <read-only> eventType=COMMUNICATIONSALARM <read-only> fmAlarmId="528" lastEventTime="2018-03-15T17:16:37.404+08:00" <read-only> majorType=193 <read-only> minorType=864264 <read-only> originalAdditionalText="This alarm is raised when the diameter connection to remote Peer fttools-DRA.dra.ericsson.se@dra.ericsson.se fails." <read-only> originalEventTime="2018-03-15T17:16:37.404+08:00" <read-only> originalSeverity=MAJOR <read-only> probableCause=342 <read-only> sequenceNumber=1127 <read-only> source="ManagedElement=ipworks_cba,SystemFunctions=1,Fm=1,FmAlarmModel=ipworksDiameterAAA,FmAlarmType=ipworksDiameterAAAPeerConnectionUnreachable,IpworksDiameterAAA,Peer=fttools-DRA.dra.ericsson.se@dra.ericsson.se" <read-only> specificProblem="Diameter AAA, Diameter Peer Connection Unreachable" <read-only>
- Clear the alarm.
# ipw-alarm --cmd clear --id <Alarm ID>
The <Alarm ID> can be found in the example output in Step 1.
Reference List
| Ericsson Documents |
|---|
| [1] Trademark Information. |
| [2] Typographic Conventions. |
| [3] Glossary of Terms and Acronyms. |
| [4] Fault Management. |