| 1 | Introduction |
| 1.1 | Alarm Description |
| 1.2 | Prerequisites |
2 | Procedure |
| 2.1 | Configuring ENUM server |
| 2.2 | Starting Management Node and Data Node |
1 Introduction
This instruction concerns alarm handling.
1.1 Alarm Description
The alarm is issued when the connections between ENUM server and MySQL NDB clusters are down.
The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
Solution |
|---|---|---|---|---|---|
|
ENUM configuration error occurs. |
The alarm is raised because of the incorrect configuration of ENUM. |
Both the attributes dbConnectString and dbConnectStringSecondary in the MO EnumServer are configured incorrectly. |
ENUM server |
ENUM server cannot provide service. |
See Section 2.1 |
|
NDB cluster is under abnormal condition. |
All Management Nodes or Data Nodes are down. |
All the NDB connections are down. |
NDB cluster |
See Section 2.2 |
- Note:
- An alarm can appear as a result of the maintenance activity.
The alarm attributes are listed and explained in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
856067 |
|
Managed Object Class |
ipworksEnum |
|
Source |
ManagedElement=<Node Name>, SystemFunctions=1,Fm=1,FmAlarmModel=IpworksEnum,FmAlarmType=ipworksEnumLostConnDB, HostName=<Hostname>,IpworksEnum |
|
Specific Problem |
|
|
Event Type |
communicationsAlarm(2) |
|
Probable Cause |
x733RemoteNodeTransmissionError(342) |
|
Additional Text |
All the NDB connections are down. DNS ENUM requests that trigger NDB queries will fail with SERVFAIL response.;uuid:<Product_UUID>(1) |
|
Perceived Severity |
Critical |
(1) <Product_UUID> is the universally unique identifier (UUID) of machine
that generates the alarm. The value can be fetched from /sys/devices/virtual/dmi/id/product_uuid on the PL
node.
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
Before starting this procedure, ensure that you have read the following documents:
1.2.2 Tools
No tools are required.
1.2.3 Conditions
No conditions.
2 Procedure
This section describes the procedure to follow to clear this alarm.
2.1 Configuring ENUM server
To clear the alarm, do the following:
- Log on to the ECLI interface.
# ssh <username>@<SC-1 or SC-2 IP Address> -p 22 -t -s cli
- Configure the MO EnumServer.
>ManagedElement=<Node Name>,IpworksFunction=1,IpworksDnsRoot=1,IpworksEnumRoot=1,EnumServer=1 (EnumServer=1)>configure (config-EnumServer=1)>dbConnectString="sc-1:1186" (config-EnumServer=1)>dbConnectStringSecondary="sc-2:1186" (config-EnumServer=1)>commit (config-EnumServer=1)>exit
- Restart the ENUM service to make the change take effect.
# ipw-ctr stop enum <hostname> # ipw-ctr start enum <hostname>
- If this alarm still exists, consult the next level of maintenance support. Further actions are outside the scope of this instruction.
2.2 Starting Management Node and Data Node
To clear the alarm, do the following:
- Log on to the SC-1.
# ssh <Username>@<SC-1 IP Address>
- Start the Management Node and Data Node.
#/etc/init.d/ipworks.mysql start-mgmd #/etc/init.d/ipworks.mysql start-ndbd
For more information on how to manage MySQL NDB Cluster, refer to Configure MySQL NDB Cluster.
- Log on to the SC-2, then start the Management Node and Data Node on SC-2.
- Confirm that the alarm has ceased. If the alarm remains, consult the next level of maintenance support. Further actions are outside the scope of this instruction.