1   Introduction

This instruction concerns alarm handling.

1.1   Alarm Description

This alarm is issued when the percentage of total failed ERH queries with respect to the total number of queries exceeds a configurable threshold.

The possible alarm causes and the corresponding fault reasons, fault locations and impacts are described in Table 1.

Table 1    Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

Solution

ERH module load error

Initialization of ERH module failed when ENUM server is started.

ERH module is initialized incorrectly.

ENUM server

MAP, INAP, or AIN query failure


Toll-free query failure

See Section 2

SS7 stack or LDAP database error

SS7 stack configuration error or LDAP database connection error.

SS7 stack is in wrong status or LDAP database has problem or stopped.

SS7 stack or LDAP

Note:  
An alarm can appear as a result of the maintenance activity.

The alarm attributes are listed and explained in Table 2.

Table 2    Alarm Attributes

Attribute Name

Attribute Value

Major Type

193

Minor Type

856100

Managed Object Class

ipworksEnumPm

Source

ManagedElement=<Node Name>,SystemFunctions=1,Pm=1,PmJob=<PM job name, he default job is ERHTPSDefaultJob>,MeasurementReader=<name>:<hostname>

Specific Problem

ERH, Total Query Error

Event Type

qualityOfServiceAlarm(11)

Probable Cause

x733ThresholdCrossed(351)

Additional Text

The percentage of total failed queries (including NP and toll-free queries) with respect to the total number of queries exceeds a configurable threshold.;uuid:<Product_UUID>(1)

Perceived Severity

Warning

(1)  <Product_UUID> is the universally unique identifier (UUID) of machine that generates the alarm. The value can be fetched from /sys/devices/virtual/dmi/id/product_uuid on the PL node.


1.2   Prerequisites

This section provides information on the documents, tools, and conditions that apply to the procedure.

1.2.1   Documents

This instruction references the following document:

1.2.2   Tools

Before starting this procedure, ensure that the following tool is available:

1.2.3   Conditions

No conditions.

2   Procedure

Do the following:

  1. Refer to ERH, NP Query Error and ERH, Toll-free Query Error to clear the alarm.
  2. Confirm that the alarm has ceased. If the alarm remains, consult the next level of maintenance support. Further actions are outside the scope of this instruction.


Copyright

© Ericsson AB 2017, 2018. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    ERH, Total Query Error         IPWorks