1 Introduction
This instruction concerns alarm handling.
1.1 Alarm Description
The alarm is issued by the ENUM FE Sync server when the ENUM FE Sync server fails to access any specific CUDB site.
The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
Solution |
|---|---|---|---|---|---|
|
CUDB server is unreachable. |
The CUDB server is unreachable because of network connection issues or other network-related glitches. |
Network connection error |
Network |
ENUM FE Sync cannot get the service from the CUDB site. All the sites are down, ENUM FE Sync fails to work. |
See Section 2.2 |
|
CUDB site is down. |
CUDB Site is down owing to maintenance activity or some other reasons. |
CUDB site |
See Section 2.3 |
- Note:
- An alarm can appear as a result of the maintenance activity.
The alarm attributes are listed and explained in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
856112 |
|
Managed Object Class |
ipworksEnum |
|
Source |
<Node Name>,SystemFunctions=1,Fm=1,FmAlarmModel=IpworksEnum,FmAlarmType=ipworksFESyncCUDBFailure,Source=IpworksEnumFESync |
|
Specific Problem |
|
|
Event Type |
communicationsAlarm(2) |
|
Probable Cause |
x733RemoteNodeTransmissionError(342) |
|
Additional Text |
This alarm is raised when all CUDB connections fail during the access by ENUM FE Sync.;uuid:<Product_UUID>(1) |
|
Perceived Severity |
Major |
(1) <Product_UUID> is
the universally unique identifier (UUID) of machine that generates
the alarm. The value can be fetched from /sys/devices/virtual/dmi/id/product_uuid on the PL node.
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
Before starting this procedure, ensure that you have read the following documents:
1.2.2 Tools
No tools are required.
1.2.3 Conditions
No conditions.
2 Procedure
This section describes the procedure to follow to clear this alarm.
2.1 Analyzing the Alarm
Do the following at the maintenance center:
- Troubleshoot the network issues.
- Check the CUDB Site.
2.2 Troubleshooting Network Issues
To clear the alarm, do the following:
- Debug and troubleshoot the network issues, for example,
ping the IP address, check the cable connection and etc.
The alarm is expected to be cleared automatically when the network connection returns to normal.
- Confirm that the alarm has ceased.
If the alarm remains, consult the next level of maintenance support. Further actions are outside the scope of this instruction.
2.3 Checking CUDB Site
To clear the alarm, do the following:
- Check whether CUDB Connection with ENUM server is configured
correctly.
For example, the failed site is site1. The following shows that two CUDB nodes are deployed in the site site1, and the IP addresses of the CUDB node are 192.168.20.14 and 10.170.15.188 respectively. Ensure that the IP addresses of site1 are configured the same as provided by the CUDB node.
>ManagedElement=<Node Name>,IpworksFunction=1,IpworksCommonRoot=1,DataBaseInfo=1, CudbManager=1,CudbServiceSite=ENUM,CudbSiteManager=1,CudbSite=Site1 (CudbSite=site1)>show CudbSite=site1 CudbNode=node2 CudbNode=node1 (CudbSite=site1)>CudbNode=node1 (CudbNode=node1)>show -v CudbNode=node1 address="192.168.20.14" cudbNodeId="node1" <default> distinguishedName="cudbUser=ENUMUser,ou=admin,dc=ericsson,dc=com" password="1:gliG5ALpb/AiV+hl2cd89uNRnnnCZCR7" poolSize=16 <default> port=389 <default> (CudbNode=node1)>up (CudbSite=site1)>CudbNode=node2 (CudbNode=node2)>show -v CudbNode=node2 address="10.170.15.188" <default> cudbNodeId="node2" distinguishedName=[] <empty> password=[] <empty> poolSize=16 <default> port=389 <default> (CudbNode=node2)>
If the configuration is not correct, try to fix the configuration. Fore more detail, refer to section Configuring CUDB Connection Pool in Configure DNS and ENUM.
If the configuration is correct, and the alarm still exists, do the following:
- Fix the issues of CUDB nodes on the failed site.
This action is outside the scope of IPWorks instruction.
- Confirm that the alarm has ceased.
If the alarm remains, consult the next level of maintenance support. Further actions are outside the scope of this instruction.