1 Introduction
This instruction concerns alarm handling.
1.1 Alarm Description
The alarm is issued when the Diameter AAA server can access none of the CUDB node certain specified CUDB site.
The possible alarm causes and the corresponding fault reasons, fault locations and impacts are described in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
Solution |
|---|---|---|---|---|---|
|
The configuration of all CUDB nodes in the specified CUDB site is incorrect. |
The configured addresses, ports, or passwords of all CUDB nodes grouped in the specified CUDB site are incorrect. |
The attribute address or port of all CUDB nodes grouped in certain CUDB site is configured incorrectly. |
Diameter AAA |
Diameter AAA cannot get the service from the CUDB site. The traffic sent to the failed site will be switched to another CUDB site (Failover mechanism). If all the sites are down, Diameter AAA fails to work. |
|
|
All nodes in the specified CUDB site are unreachable. |
All nodes in the specified CUDB site are unreachable because of network connection issues or other network related fault. |
Network connection error. |
Network |
||
|
All nodes in the specified CUDB site are down |
All nodes grouped in the specific CUDB site are down because of maintenance activity or some other reasons. |
All nodes grouped in the specific CUDB site are not started by some reasons. |
CUDB nodes |
- Note:
- An alarm can appear as a result of the maintenance activity.
The alarm attributes are listed and explained in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
864267 |
|
Managed Object Class |
IpworksDiameterAAA |
|
Source |
ManagedElement=<Node Name>,SystemFunctions=1,Fm=1,FmAlarmModel=ipworksDiameterAAA,FmAlarmType=ipworksDiameterAAACUDBSiteFailure,HostName=<hostname>,IpworksDiameterAAA,Site-Name=<site name> |
|
Specific Problem |
|
|
Event Type |
communicationsAlarm(2) |
|
Probable Cause |
x733RemoteNodeTransmissionError(342) |
|
Additional Text |
CUDB Site %s is lost when AAA tries to connect to CUDB Site.;uuid:<Product_UUID>(1) |
|
Perceived Severity |
Major |
(1) <Product_UUID> is the universally unique identifier
(UUID) of machine that generates the alarm. The value can be fetched
from /sys/devices/virtual/dmi/id/product_uuid on the PL node.
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
Before starting this procedure, ensure that the following document has been read:
1.2.2 Tools
Not available.
1.2.3 Conditions
Not applicable.
1.3 Related Information
Trademark information, typographic conventions, and definition and explanation of abbreviations and terminology can be found in the following documents:
2 Procedure
This section describes the procedure to follow to clear this alarm.
2.1 Correcting CUDB Connection Configuration
To clear the alarm, do the following:
- Get information from the alarm attribute Additional Text to know which CUDB site failed. For example, "site1".
- Check whether the CUDB connection configuration with AAA
is correct.
For example, the following example shows that two CUDB nodes ("node1" and "node2") are deployed in the failed site ("site1"), and the IP addresses of the CUDB nodes are 10.170.15.186 and 10.170.15.188 respectively.
Ensure that the IP addresses, port, password, etc. in "site1" are configured as the same as provided by the CUDB node.
>ManagedElement=<Node Name>,IpworksFunction=1,IpworksCommonRoot=1,⇒ DataBaseInfo=1,CudbManager=1,CudbServiceSite=PKI,CudbSiteManager=1,CudbSite=site1 (CudbSite=site1)>show CudbSite=site1 CudbNode=node2 CudbNode=node1 (CudbSite=site1)>CudbNode=node1 (CudbNode=node1)>show -v CudbNode=node1 address="10.170.15.186" cudbNodeId="node1" <default> distinguishedName=[] <empty> password=[] <empty> poolSize=16 <default> port=389 <default> (CudbNode=node1)>up (CudbSite=site1)>CudbNode=node2 (CudbNode=node2)>show -v CudbNode=node2 address="10.170.15.188" <default> cudbNodeId="node2" distinguishedName=[] <empty> password=[] <empty> poolSize=16 <default> port=389 <default> (CudbNode=node2)>
If the configuration is not correct, try to correct the configuration. For more information, refer to section Configuring CUDB Connection Pool in Configure EPC AAA.
- Confirm the alarm has ceased.
If the alarm remains, consult the next level of maintenance support. Further actions are outside the scope of this instruction.
2.2 Troubleshooting the Network Issues
Debug and troubleshoot the network issues, for example, ping the IP address, check the cable connection and so on.
The alarm is expected to be cleared automatically when one of CUDB nodes’ network connection returns to normal.
2.3 Checking the CUDB Node Status
Contact CUDB support, and check the status of all CUDB nodes grouped in the specific CUDB site. If all CUDB nodes are really down, try to debug and troubleshoot the issues. Further actions are outside the scope of this instruction.
The alarm is expected to be cleared automatically when one of the CUDB nodes’ status returns to normal.