Diameter AAA, Server Cannot Connect to CUDB Site
IPWorks

Contents

1Introduction
1.1Alarm Description
1.2Prerequisites
1.3Related Information

2

Procedure
2.1Correcting CUDB Connection Configuration
2.2Troubleshooting the Network Issues
2.3Checking the CUDB Node Status

1   Introduction

This instruction concerns alarm handling.

1.1   Alarm Description

The alarm is issued when the Diameter AAA server can access none of the CUDB node certain specified CUDB site.

The possible alarm causes and the corresponding fault reasons, fault locations and impacts are described in Table 1.

Table 1    Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

Solution

The configuration of all CUDB nodes in the specified CUDB site is incorrect.

The configured addresses, ports, or passwords of all CUDB nodes grouped in the specified CUDB site are incorrect.

The attribute address or port of all CUDB nodes grouped in certain CUDB site is configured incorrectly.

Diameter AAA

Diameter AAA cannot get the service from the CUDB site. The traffic sent to the failed site will be switched to another CUDB site (Failover mechanism). If all the sites are down, Diameter AAA fails to work.

Section 2.1

All nodes in the specified CUDB site are unreachable.

All nodes in the specified CUDB site are unreachable because of network connection issues or other network related fault.

Network connection error.

Network

Section 2.2

All nodes in the specified CUDB site are down

All nodes grouped in the specific CUDB site are down because of maintenance activity or some other reasons.

All nodes grouped in the specific CUDB site are not started by some reasons.

CUDB nodes

Section 2.3

Note:  
An alarm can appear as a result of the maintenance activity.

The alarm attributes are listed and explained in Table 2.

Table 2    Alarm Attributes

Attribute Name

Attribute Value

Major Type

193

Minor Type

864267

Managed Object Class

IpworksDiameterAAA

Source

ManagedElement=<Node Name>,SystemFunctions=1,Fm=1,FmAlarmModel=ipworksDiameterAAA,FmAlarmType=ipworksDiameterAAACUDBSiteFailure,HostName=<hostname>,IpworksDiameterAAA,Site-Name=<site name>

Specific Problem

Diameter AAA, Server Cannot Connect to CUDB Site

Event Type

communicationsAlarm(2)

Probable Cause

x733RemoteNodeTransmissionError(342)

Additional Text

CUDB Site %s is lost when AAA tries to connect to CUDB Site.;uuid:<Product_UUID>(1)

Perceived Severity

Major

(1)  <Product_UUID> is the universally unique identifier (UUID) of machine that generates the alarm. The value can be fetched from /sys/devices/virtual/dmi/id/product_uuid on the PL node.


1.2   Prerequisites

This section provides information on the documents, tools, and conditions that apply to the procedure.

1.2.1   Documents

Before starting this procedure, ensure that the following document has been read:

1.2.2   Tools

Not available.

1.2.3   Conditions

Not applicable.

1.3   Related Information

Trademark information, typographic conventions, and definition and explanation of abbreviations and terminology can be found in the following documents:

2   Procedure

This section describes the procedure to follow to clear this alarm.

2.1   Correcting CUDB Connection Configuration

To clear the alarm, do the following:

  1. Get information from the alarm attribute Additional Text to know which CUDB site failed. For example, "site1".
  2. Check whether the CUDB connection configuration with AAA is correct.

    For example, the following example shows that two CUDB nodes ("node1" and "node2") are deployed in the failed site ("site1"), and the IP addresses of the CUDB nodes are 10.170.15.186 and 10.170.15.188 respectively.

    Ensure that the IP addresses, port, password, etc. in "site1" are configured as the same as provided by the CUDB node.

    >ManagedElement=<Node Name>,IpworksFunction=1,IpworksCommonRoot=1,⇒
    DataBaseInfo=1,CudbManager=1,CudbServiceSite=PKI,CudbSiteManager=1,CudbSite=site1
    (CudbSite=site1)>show
    CudbSite=site1
       CudbNode=node2
       CudbNode=node1
    (CudbSite=site1)>CudbNode=node1
    (CudbNode=node1)>show -v
    CudbNode=node1
       address="10.170.15.186"
       cudbNodeId="node1" <default>
       distinguishedName=[] <empty>
       password=[] <empty>
       poolSize=16 <default>
       port=389 <default>
    (CudbNode=node1)>up
    (CudbSite=site1)>CudbNode=node2
    (CudbNode=node2)>show -v
    CudbNode=node2
       address="10.170.15.188" <default>
       cudbNodeId="node2"
       distinguishedName=[] <empty>
       password=[] <empty>
       poolSize=16 <default>
       port=389 <default>
    (CudbNode=node2)>
    

    If the configuration is not correct, try to correct the configuration. For more information, refer to section Configuring CUDB Connection Pool in Configure EPC AAA.

  3. Confirm the alarm has ceased.

    If the alarm remains, consult the next level of maintenance support. Further actions are outside the scope of this instruction.

2.2   Troubleshooting the Network Issues

Debug and troubleshoot the network issues, for example, ping the IP address, check the cable connection and so on.

The alarm is expected to be cleared automatically when one of CUDB nodes’ network connection returns to normal.

2.3   Checking the CUDB Node Status

Contact CUDB support, and check the status of all CUDB nodes grouped in the specific CUDB site. If all CUDB nodes are really down, try to debug and troubleshoot the issues. Further actions are outside the scope of this instruction.

The alarm is expected to be cleared automatically when one of the CUDB nodes’ status returns to normal.



Copyright

© Ericsson AB 2017, 2018. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    Diameter AAA, Server Cannot Connect to CUDB Site         IPWorks