CEE Installation
Cloud Execution Environment

Contents

1Introduction
1.1Prerequisites
1.2General Prerequisites
1.3HW-Specific Prerequisites

2

Installation Flow for Multi-Server Deployments
2.1Multi-Server CEE Installation on HP Hardware
2.2Multi-Server CEE Installation on BSP Hardware
2.3Multi-Server CEE Installation on Dell Hardware
2.4Multi-Server CEE Installation on HDS vPOD

3

Installation Flow for Single Server Deployments
3.1Single Server CEE Installation on Dell Hardware

4

Post-Installation Activities

Reference List

1   Introduction

This document summarizes the complete procedure for deploying a Cloud Execution Environment (CEE) region.

1.1   Prerequisites

This section describes the prerequisites that must be fulfilled before CEE can be installed.

1.2   General Prerequisites

This document covers CEE installation on a hardware configuration that complies to BOM for Certified HW Configurations, Reference [1], and is installed according to one of the following documents:

Note:  
The current release of CEE is not verified on BSP hardware. The installation flow and document references for CEE on a BSP platform only serve as a reference.

The Single Server setup is a small footprint infrastructure version of CEE. It contains one single compute host and one Virtual Cloud Infrastructure Controller (vCIC) installed on it.

The Single Server setup does not contain the following:

However, it is a prerequisite for the installation to have a switch that is not configured by CEE. (It can be a budget switch and configuration has to performed manually.)

This switch must be capable of the following:

After configuring the switch, it has to be connected to the following system elements for the single server CEE installation:

1.3   HW-Specific Prerequisites

For the hardware-specific prerequisites, refer to the prerequisites in each individual procedure for the deployment, as indicated in Table 1.

Table 1    Hardware-Specific Prerequisites
 

HP
Multi-
Server

BSP
Multi-
Server

Dell
Multi-
Server

HDS
Multi-
Server

Other
Multi-Server

Dell
Single
Server

HP c7000 HW Installation

 

Yes

     

Supplier documentation for HW installation

 

Preparation of Kickstart Server

 

Yes

Yes

Yes

 

Yes

Yes

Extreme X460 Configuration

 

Yes

 

Yes

 

Yes, or supplier documents for installation and configuration of Control Switches

 

Extreme X670V Configuration / Extreme X770 Configuration

Yes

 

Yes

 

Yes, or supplier documents for installation and configuration of Switches for Traffic and Storage Network

 

VNX5400 SW Installation
Optional

Yes

 

Yes

 

Yes, or supplier documents for installation and configuration of the used storage system

 

HP c7000 Configuration

 

Yes

     

Supplier documents for server and server BIOS configuration

 

HP c7000 Server BIOS Configuration

 

Yes

       

SW Installation in Multi-Server Deployment

 

Yes

Yes

Yes

 

Yes

 

Atlas SW Installation

Yes

Yes

Yes

Yes

Yes

Yes

Fault Management Configuration Guide

 

Yes

Yes

Yes

 

Yes

Yes

External Networking Connectivity for CEE Tenants in HP and Dell Multi-Server Deployment

 

Yes

 

Yes

 

Yes

 

DC Firewall Hardening Guide

 

Yes

Yes

Yes

Yes

Yes

Yes

System Hardening Guideline

 

Yes

Yes

Yes

Yes

Yes

Yes

Health Check Procedure

 

Yes

Yes

Yes

Yes

Yes

Yes

Fuel Synchronization

Yes

Yes

Yes

Yes

Yes

Yes

BSP Installation, Reference [5]

 

Yes

       

BSP Hardware Description, Reference [6]

 

Yes

       

Identify BSP Hardware, Reference [7]

 

Yes

       

BSP System Capabilities, Reference [8]

 

Yes

       

BSP Jumpstart Instruction, Reference [9]

 

Yes

       

Add Shelf, Reference [10]

 

Yes

       

BSP Backup and Restore, Reference [11]

 

Yes

       

BSP Initial Configuration, Reference [12]

 

Yes

       

External Networking Connectivity for CEE Tenants in BSP Deployment

 
 

Yes

       

Configure Northbound Interface in BSP, Reference [13]

 

Yes

       

Dell PowerEdge R630 HW Installation

 
   

Yes

     

Dell PowerEdge R630 Server Configuration

 
   

Yes

   

Yes

Dell PowerEdge R630 Server BIOS Configuration for CEE

 
   

Yes

   

Yes

SW Installation in Single Server Deployment

 
         

Yes

External Networking Connectivity for CEE Tenants in Single Server Deployment

 
         

Yes

vFuel On Demand Use

 
         

Yes

Atlas On Demand Use

 
         

Yes

Hyperscale Datacenter System 8000 Customer Documentation, Reference [2]

     

Yes

   

CEE on HDS Installation, Reference [3]

     

Yes

   

2   Installation Flow for Multi-Server Deployments

This section describes the complete installation procedure for multi-server CEE deployments.

Multi-server CEE deployments consist of the following parts:

In most cases, two units are used to achieve redundancy.

For the installation of multi-server CEE, depending on the deployed certified hardware environment, follow the relevant procedure:

The general installation flow of multi-server CEE consists of the following steps:

  1. Creating site-specific configuration file to be used during the SW installation by following the instructions in Configuration File Guide.
    Note:  
    The configuration file must be in place since data needs to be consistent.

  2. Installation of CEE hardware according to the supplier documents.
  3. Preparation to install and configuration of the Control Switches.
  4. Preparation to install and configuration of the Switches for Traffic and Storage Network.
  5. Installation of the Storage system.
    Note:  
    This step is optional.

  6. Configuration of the Server System, including the following elements:
    • Redundant Array of Independent Disks (RAID) configuration
    • Setting the boot mode
    • Configuration of NTP settings or setting system time
    • Configuration of the subrack management interface
  7. Installation and configuration of a kickstart server according to Preparation of Kickstart Server.
  8. Installation of SW according to the instructions in SW Installation in Multi-Server Deployment.
  9. Performing the post-installation activities, see Section 4.

2.1   Multi-Server CEE Installation on HP Hardware

This section describes multi-server installation on HP hardware.

The server, storage and switching components of the hardware environment with VNX Storage system are shown in Figure 1fig_HP_VNX_eps.

Figure 1   CEE System on HP HW, VNX

Figure 1   CEE System on HP HW, VNX

The server, storage, and switching components of the HW environment with ScaleIO Storage solution are shown in fig_HP_ScaleIO_eps Figure 2.

Figure 2   CEE System on HP HW, ScaleIO

Figure 2   CEE System on HP HW, ScaleIO

Follow the below steps for installation:

  1. Create site-specific configuration file to be used during the SW installation by following the instructions in Configuration File Guide.
    Note:  
    The configuration file must be in place since data needs to be consistent.

  2. Install CEE hardware according to HP c7000 HW Installation.
  3. Prepare to install and configure the Control Switches by following the instructions in Extreme X460 Configuration.
  4. Prepare to install and configure the Switches for Traffic and Storage Network by following the instructions in Extreme X670V Configuration or Extreme X770 Configuration.
    Note:  
    Configure the Switch for Storage Network only if VNX storage system is used.

  5. Install the Storage system according to VNX5400 SW Installation.
    Note:  
    This step is optional. VNX and EMC2 ScaleIO are mutually exclusive. Only perform this step if VNX Storage system is used.

  6. Configure the Server System according to the instructions in HP c7000 Configurationand HP c7000 Server BIOS Configuration.
  7. Install and configure a kickstart server according to Preparation of Kickstart Server.
  8. Install SW according to the instructions in SW Installation in Multi-Server Deployment.
  9. Perform the post-installation activities, see Section 4.

2.2   Multi-Server CEE Installation on BSP Hardware

This section describes multi-server installation on BSP hardware.

The server, storage and switching components of the hardware environment are shown in Figure 3fig_BSP_SIO_eps.

Figure 3   CEE System on BSP HW, ScaleIO

Figure 3   CEE System on BSP HW, ScaleIO

Follow the below steps for installation:

  1. Create site-specific configuration file to be used during the SW installation by following the instructions in Configuration File Guide.
    Note:  
    The configuration file must be in place since data needs to be consistent.

  2. Install CEE hardware according to BSP Hardware Installation, see Reference [14].
  3. Configure the Server System according to the instructions in BSP Initial Configuration, Reference [12].

    By using the BSP instruction Add Shelf, Reference [10], add all the shelves that contain blades to be part of the CEE region to the BSP.

Note:  
If GEP7 blades are used, CEE can only be deployed if the firmware of the Ethernet interfaces are updated to version 5.04 or later on all GEP7 blades.

  1. Create a BSP configuration backup by using BSP Backup and Restore, Reference [11]. The backup name must be in accordance with what is configured in cmx_switch.yaml, refer to Configuration File Guide.
  2. Install and configure a kickstart server according to Preparation of Kickstart Server.
  3. Install SW according to the instructions in SW Installation in Multi-Server Deployment.
  4. Perform the post-installation activities, see Section 4.

2.3   Multi-Server CEE Installation on Dell Hardware

This section describes Multi-Server installation on Dell hardware.

The server, storage and switching components of the hardware environment with VNX Storage system are shown in Figure 4fig_Dell_VNX_eps.

Figure 4   CEE System on Dell HW, VNX

Figure 4   CEE System on Dell HW, VNX

The server, storage, and switching components of the HW environment with ScaleIO Storage solution are shown in fig_Dell_SIO_eps Figure 5.

Figure 5   CEE System on Dell HW, ScaleIO

Figure 5   CEE System on Dell HW, ScaleIO

Follow the below steps for installation:

  1. Create site-specific configuration file to be used during the SW installation by following the instructions in Configuration File Guide.
    Note:  
    The configuration file must be in place since data needs to be consistent.

  2. Install CEE hardware according to Dell PowerEdge R630 HW Installation
  3. Prepare to install and configure the Control Switches by following the instructions in Extreme X460 Configuration.
  4. Prepare to install and configure the Switches for Traffic and Storage Network by following the instructions in Extreme X770 Configuration.
    Note:  
    Configure the Switch for Storage Network only if VNX storage system is used.

  5. Install the Storage system according to VNX5400 SW Installation.
    Note:  
    This step is optional. VNX and EMC2 ScaleIO are mutually exclusive. Only perform this step if VNX Storage system is used.

  6. Configure the Server System according to the instructions in Dell PowerEdge R630 Server Configuration and Dell PowerEdge R630 Server BIOS Configuration for CEE.
  7. Install and configure a kickstart server according to Preparation of Kickstart Server.
  8. Install SW according to the instructions in SW Installation in Multi-Server Deployment.
  9. Perform the post-installation activities, see Section 4.

2.4   Multi-Server CEE Installation on HDS vPOD

This section describes Multi-Server installation on an HDS Virtualized Performance Optimized Datacenter (vPOD).

The server, storage, and switching components of the environment with ScaleIO Storage solution are shown in fig_HDS_SIO_eps Figure 6

Figure 5   CEE System on HDS vPOD, ScaleIO

Figure 6   CEE System on HDS vPOD, ScaleIO

Follow the below steps for installation:

  1. If required, install and configure HDS hardware according to the End-to-End Installation Guide document of Hyperscale Datacenter System 8000 Customer Documentation, Reference [2].
  2. Create and configure vPOD for the CEE region, and assign compute to the vPOD, according to Multi-Server System Dimensioning Guide, CEE R6 and Hyperscale Datacenter System 8000 Customer Documentation, Reference [2].

    If applicable, note down the output of vPOD creation to use in Step 3. For more information, refer to the Configuration File Guide

    Note:  
    If you are a DC customer, order a vPOD from the DC owner with the required capacity planned in accordance with Multi-Server System Dimensioning Guide, CEE R6.

  3. Create site-specific configuration file to be used during the SW installation by following the instructions in Configuration File Guide and, if applicable, using the output of vPOD creation and configuration in Step 2.
    Note:  
    The configuration file must be in place since data needs to be consistent.

  4. Perform CEE installation on the vPOD as described in CEE on HDS Installation, Reference [3], including the following:
    • Preparation of the kickstart server
    • Configuration of networks
    • Deployment of CEE
  5. Perform the post-installation activities, see Section 4.

3   Installation Flow for Single Server Deployments

This section describes the complete installation procedure for single server CEE deployments.

Single server CEE deployments consist of the following parts:

No redundancy or high availability is provided.


3.1   Single Server CEE Installation on Dell Hardware

This section describes single server installation on Dell hardware.

Figure 7   CEE System on Dell HW

Follow the below steps for installation:

  1. Create site-specific configuration file to be used during the SW installation by following the instructions in Configuration File Guide.
    Note:  
    The configuration file must be in place since data needs to be consistent.

  2. Install CEE hardware according to the supplier documents.
  3. Configure the Server System according to the instructions in Dell PowerEdge R630 Server Configuration and Dell PowerEdge R630 Server BIOS Configuration for CEE.
  4. Install and configure a kickstart server according to Preparation of Kickstart Server.
  5. Install SW according to the instructions in SW Installation in Single Server Deployment.
  6. Perform the post-installation activities, see Section 4.

4   Post-Installation Activities

This section describes the post-installation activities needed for CEE.

Do the following:

  1. Configure alarm destinations by following the instructions in Fault Management Configuration Guide.
  2. Set up the firewall according to the recommendations in DC Firewall Hardening Guide.
  3. Perform system hardening by following the instructions in System Hardening Guideline.
  4. Configure external connections by following the instructions in the user guide relevant to the CEE hardware deployment:
  5. Install CEE management software by following the instructions in Atlas SW Installation.
  6. In case of single server deployment, disable Atlas by following the instructions in Atlas On Demand Use.
  7. For disaster recovery purposes, fetch vFuel image and copy the backup to another storage place out of scope of CEE. To identify the location of the vFuel image within the CEE region, refer to the document Fuel Synchronization.
  8. In case of single server deployment, disable vFuel by following the instructions in vFuel On Demand Use.
  9. Execute health check according to Health Check Procedure.

Reference List

[1] BOM for Certified HW Configurations, 1/006 51-CSA 113 125/5 Uen
[2] Hyperscale Datacenter System 8000 Customer Documentation, 2/1551-LZN 901 5032
[3] CEE on HDS Installation, 1/1531-CNA 403 3305/2
[4] IP and VLAN Plan, 2/102 62-CRA 119 1862/5 Uen
[5] BSP Installation, 1531-APP 111 01 Uen
[6] BSP Hardware Description, 1/1551-APP 111 01 Uen
[7] Identify BSP Hardware, 1551-CRA 119 1772 Uen
[8] BSP System Capabilities, 4/1551-APP 111 01 Uen
[9] BSP Jumpstart Instruction, 2/1531-APP 111 01 Uen
[10] Add Shelf, 16/1543-APR 901 0549/1 Uen
[11] BSP Backup and Restore, 25/1543-APR 901 0549/1 Uen
[12] BSP Initial Configuration, 3/1531-APP 111 01 Uen
[13] Configure Northbound Interface in BSP, 2/1543-APR 901 0549/1 Uen
[14] BSP Hardware Installation, 1/1531-CRA 119 1772 Uen


Copyright

© Ericsson AB 2016. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    CEE Installation         Cloud Execution Environment