1 Introduction
This instruction concerns alarm handling.
1.1 Alarm Description
The alarm is issued by the Managed Object (MO) Node when the periodic supervision algorithm detects that the compute host has failed the availability test three consecutive times, and fence_compute_before_evacuation was set to true (meaning that the compute will be fenced down), but fencing was not successful.
The severity of the alarm is CRITICAL or CLEARED.
The possible alarm causes and fault locations are explained in Table 1.
|
Alarm |
Description |
Fault |
Fault |
Impact |
|---|---|---|---|---|
|
Out-of-band management password has been changed |
The out-of-band management of the compute node has been changed |
Due to security reasons the out-of-band management password has been changed for the compute node, but fencing configuration has not been updated |
Controller nodes |
Fencing will not be successful due to password change |
|
Compute malfunction |
The affected compute is malfunctioning |
The compute cannot be fenced due to a hardware related error (and out-of-band management is unable to switch off the server or blade) |
Compute node |
Fencing will not be successful due to hardware error |
|
Network issue between controller and out-of-band management system |
The fencing solution on the controllers is not able to communicate to the out-of-band management of the compute |
Network issue prevents the communication from the controller node to the out-of-band management system |
Network between controller and out of band management |
Fencing will not be successful due to network error |
The following is the consequence for the node if the alarm is not solved:
- The virtual machines (VMs) running on the affected compute node cannot be evacuated, as evacuation will only happen after a successful fencing action. This causes unnecessary downtime for VMs that should be evacuated (VMs that have their ha-policy set to ha-offline).
- Failed fencing prevents the automatic recovery of the compute host, reducing resource availability and the availability of the VMs with ha-policy: managed-on-host, until the compute host is manually restarted or replaced by the operator.
The alarm attributes are listed in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
2031716 |
|
Managed Object Class |
Node |
|
Managed Object Instance |
Region=<name_of_the_region>, |
|
Specific Problem |
Fencing failed |
|
Event Type |
communicationsAlarm (2) |
|
Probable Cause |
protectionMechanismFailure (81) |
|
Additional Text |
;uuid=<hw_uuid_of_corresponding_server> |
|
Severity |
CRITICAL or CLEARED |
- Note:
- The alarm does not specify which VMs are affected. Separate VM Unavailable alarms are issued for each one.
For more information about the VM Unavailable alarm, refer to VM Unavailable.
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
Not applicable.
1.2.2 Tools
No tools are required.
1.2.3 Conditions
Before starting this procedure, ensure that the following conditions are met:
- Information about how to connect and use out-of-band management is available.
- Information whether an out-of-band management password was changed since the last reconfiguration of the fencing system is available.
2 Procedure
This section describes the procedure to follow when this alarm is received.
2.1 Actions
Perform the following:
- Use the unqualified part of the hostname to find out the
number of the corresponding shelf and server.
The unqualified hostname is displayed in the following format:
compute-<shelf_id>-<blade_id>
The first value shows the number of the shelf, while the second value shows the number of the server or blade.
- Check where CM-HA is running and note the controller.
You can get the information by issuing the following command on an
arbitrary controller:
crm resource status p_cmha
- Check the password in the /etc/fencing_config/fencing.yaml file on the vCICs, if it contains the right password for the out-of-band
management of the affected compute.
The following scenarios are possible:
- If the password in the file does not match the actual
password, reconfigure the fencing subsystem. For more information,
refer to the Runtime Configuration Guide.
Wait for 10 minutes after reconfiguring the fencing subsystem to see if the alarm ceases. If the alarm ceases, exit this procedure.
- Or the password in the file matches the actual password. In this case, proceed to Step 4.
- If the password in the file does not match the actual
password, reconfigure the fencing subsystem. For more information,
refer to the Runtime Configuration Guide.
- Check the network
connectivity from the controller towards the out-of-band management
by using SSH.
The following scenarios are possible:
- The connection attempt is not successful from the controller
to the out-of-band management. Make sure that the out-of-band management
system is available and restart it, if needed. For more information
on how to restart the out-of-band management system, refer to the
product documentation of the out-of-band management solution.
After the restart of the out-of-band management system, restart CM-HA service by issuing the following command on a controller:
crm resource restart p_cmha
If the alarm ceases, exit this procedure.
- Or the restart of out-of-band management did not solve the problem. In this case, proceed to Step 5.
- The connection attempt is not successful from the controller
to the out-of-band management. Make sure that the out-of-band management
system is available and restart it, if needed. For more information
on how to restart the out-of-band management system, refer to the
product documentation of the out-of-band management solution.
- Check the network
connectivity from the controller towards other network addresses.
The following scenarios are possible:
- The connection attempt is not successful from the controller
to other network addresses. Reboot the controller.
reboot -f
If the alarm ceases, exit this procedure.
- Or the restart of the controller did not solve the problem. In this case, proceed to Step 6.
- The connection attempt is not successful from the controller
to other network addresses. Reboot the controller.
- Check the compute node via
out-of-band management. If it's not available, replace the server
as described in Server Replacement.
The following scenarios are possible:
- The replacement process was successful, the server was fenced down, and the alarm ceases. If the alarm ceases, exit this procedure.
- Or the replacement did not solve the problem. In this case, proceed to Step 7.
- Collect troubleshooting data as described in the Data Collection Guideline.
- Contact the next level of maintenance support.
Further actions are outside the scope of this instruction.
- The job is completed.
3 Additional Information
The alarm is ceased for a compute host in the below cases:
- The compute host is fenced down successfully by its out-of-band management.
- The compute host is recovered.