1 Introduction
This Operational Instruction describes how to upgrade the firmware for an Extreme switch.
Switches are upgraded in pairs, and this document describes procedures for one pair of switches. In case of 2 pairs of switches, repeat the procedures for the second pair.
The upgrade involves the following steps:
- Identifying the switch role
- Identifying the switch status
- Checking that the switch is functional
- Performing the upgrade
- Rebooting and activating the switch
1.1 Concepts
Before starting the procedure, ensure that the terminology is understood:
|
Switch |
Status |
|---|---|
|
Selected switch |
The switch selected for upgrade |
|
Upgraded switch |
The switch after its upgrade |
|
Other switch |
The switch within the pair that is not yet selected for upgrade |
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
Before starting the upgrade procedure, ensure that the following documents are available, read and understood:
- The address variables are summarized in the table below.
For more information, refer to the IP and VLAN plan, Reference [1].
Network/VLAN
IPv4 Address Variable
fuel_ctrl_sp (admin)
<fuel_static_ip>
fuel_ctrl_sp (admin)
<vcic_dynamic_ip_"static pool">
Traffic
cee_ctrl_sp
<traffic_switch_a_static_ip>
Traffic
cee_ctrl_sp
<traffic_switch_b_static_ip>
Storage
cee_ctrl_sp
<storage_switch_a_static_ip>
Storage
cee_ctrl_sp
<storage_switch_b_static_ip>
Control
cee_ctrl_sp
<control_switch_a_static_ip>
Control
cee_ctrl_sp
<control_switch_b_static_ip>
- Security User Guide
- System Hardening Guideline
- Extreme X460 Configuration for X460 switches
- Note:
- The procedure depends on the role of the switch.
If there are two X460 switches, they are control switches.
If there are only two X670V switches, then both are mixed switches, with both traffic and storage switch functions.
If there are four X670V switches, or four X770 switches, then there are two traffic switches combined with two storage switches.
Traffic switches and mixed switches are operated using Neutron, but storage switches are not. As such, the steps for Neutron do not apply in case of pure storage switches.
Variables used in the commands are listed below:
|
Variable |
Value |
|---|---|
|
<user_name> |
Example: admin |
|
<switch_name> |
<cee_region_name>_TRAFFIC_SWA_X770 |
|
<cee_region_name>_TRAFFIC_SWB_X770 | |
|
<cee_region_name>_TRAFFIC_SWA_X670V | |
|
<cee_region_name>_TRAFFIC_SWB_X670V | |
|
<cee_region_name>_STORAGE_SWA_X770 | |
|
<cee_region_name>_STORAGE_SWB_X770 | |
|
<cee_region_name>_STORAGE_SWA_X670V | |
|
<cee_region_name>_STORAGE_SWB_X670V | |
|
<cee_region_name>_CONTROL_SWA_X460 | |
|
<cee_region_name>_CONTROL_SWB_X460 | |
|
<switch_ip> |
<traffic_switch_a_static_ip> |
|
<traffic_switch_b_static_ip> | |
|
<storage_switch_a_static_ip> | |
|
<storage_switch_b_static_ip> | |
|
<control_switch_a_static_ip> | |
|
<control_switch_b_static_ip> | |
|
Example: 192.168.2.2 |
1.2.2 Conditions
Before starting the upgrade procedure, ensure that the following conditions are met:
- The new version of the Extreme switch image has been uploaded or copied to either the vFuel master, a terminal server, or maintenance laptop.
- The pair(s) of Extreme switches to be upgraded are fully functional and alarm-free.
- Check the Release Notes of the new firmware to confirm that the new firmware supports the switch model.
2 Procedure
This section describes the firmware upgrade procedure for one pair of switches.
In case of 2 or more pairs of switches, repeat the procedures for the second pair.
2.1 Identify Switch and Switch Status
If there are two X460 switches, then they are control switches, go to Section 2.2.
If the switch is a storage switch, go to Section 2.2.
Identify the switch status:
- Check that the switch status is ACTIVE. Perform this step for both switches.
root@node-6: neutron device-show <switch_name>
Example 1 Switch Details
+-----------------------+--------------------------------------+ | Field | Value | +-----------------------+--------------------------------------+ | admin_state_up | True | | device_type | TOR_SWITCH | | firmware_version | 15.4.1 | | id | 3757da15-7942-4db9-98d5-c05ecfefc5b8 | | management_ip_address | 192.168.6.1 | | model | SummitXX70V | | name | DC154_SWA_XX70V | | password | NetworkAdmin | | status | ACTIVE | | user_name | network_admin | | vendor | extreme | | vr_total | 63 | +-----------------------+--------------------------------------+
For more information, refer to the Data Collection Guideline.
2.2 Log on to the Selected Switch
- Log on to the switch by either of the following ways:
- Check for warnings, errors, and critical statements in
the switch log.
<switch_name>.1 # show log severity [critical | error | warning ] chronological
<switch_name>.1 # show log severity ⇒ [critical | error | warning ] chronological
- Note:
- If the switch log shows errors or critical statements, contact the next level of maintenance support.
- Log out of the selected switch.
<switch_name>.2 # logout
- If the switch is a storage switch, go to Section 2.4.
- If the switch is a control switch, continue with section Configuration of Switch of the Extreme X460 Configuration document.
2.3 Set Switch to Maintenance Mode
Perform the following steps for the selected switch:
- Switch the device status to maintenance in Neutron. Use the following command:
neutron device-update <switch_name> --status=MAINTENANCE
Example 2 Switch Device Status to Maintenance
neutron device-update <cee_region_name>_TRAFFIC_SWB_X670V --status=MAINTENANCE
- Verify that the device status has changed to maintenance. Contact the next level of maintenance support if the device status does not change.
- Continue with Section 2.4.
2.4 Select Download Partition
- Use the management_ip_address on the VLAN cee_ctrl_sp to log on to
the selected switch.
ssh network_admin@<management_ip_address_of_the_selected_switch>
ssh network_admin@⇒ <management_ip_address_of_the_selected_switch>
Select the partition to use when downloading the image:
- Use the show switch command to determine
the selected and booted images.
- Note:
- The selected image partition indicates which image is to be used at the next reboot. The booted image partition indicates the image used at the last reboot.
- Check if the selected and booted images are in the primary or secondary partition.
- Select the partition for installing the new firmware image. Do not select the partition from where the current image is booted.
2.5 Install EXOS Core Image
To install the image, do the following steps:
- Download and validate the new image to the switch using
SCP/SCP2:
scp2 {vr vr_name} user [hostname | ipaddress]:remote_file local_filescp2 {vr vr_name} user ⇒ [hostname | ipaddress]:remote_file local_file
Example 3 Validate Image Using SCP/SCP2
scp2 vr "VR-Default" root@<fuel_static_ip>:/var/lib/tftpboot⇒ /summitX-15.6.1.4.xos summitX-15.6.1.4.xos
- Install the image:
install image local_file {partition}
Example 4 Install Image Command
install image summitX-15.6.1.4.xos secondary
- Note:
- In the above example, the current image is booted from the primary partition, therefore, the secondary partition is selected.
2.6 Install Modular Software Package
To add the SSH module to the switch, perform the following steps:
- Download the new image to the switch using SCP/SCP2:
scp2 {vr vr_name} user [hostname | ipaddress]:remote_file local_filescp2 {vr vr_name} user ⇒ [hostname | ipaddress]:remote_file local_file
Example 5 Download Image Using SCP/SCP2
scp2 vr "VR-Default" root@<fuel_static_ip>:/var/lib/tftpboot⇒ /summitX-15.6.1.4-ssh.xmod summitX-15.6.1.4-ssh.xmod
- Install the software module:
install image local_file {partition}
Example 6 Install Image Command
install image summitX-15.6.1.4-ssh.xmod secondary
- Note:
- In the above example, the current image is booted from the primary partition, therefore, the secondary partition is selected.
2.7 Use the Newly Installed Partition
Select the newly installed partition to use after the reboot:
use image {partition} <partition>
Example 7 Use Image Command
use image partition secondary
2.8 Reboot and Activate the New Packages
Reboot and activate the new packages:
- Reboot the system:
reboot
Result:
The following options are available:y Save and reboot n Reboot without save cr Cancel command - Choose n from the available options.
2.9 Check the Status of the Upgraded Switch
Check the status of the upgraded switch:
- Log on to the upgraded Extreme switch, and issue the following
command:
show switch
For an output example, see Example 8.
Example 8 Switch Status
Current State: OPERATIONAL
Image Selected: secondary
Image Booted: secondary
Primary ver: 15.6.1.4
Secondary ver: 15.4.1.3
Config Selected: ericsson_default.cfg
Config Booted: ericsson_default_backup.cfg
- Check that the switch state is OPERATIONAL, and the new EXOS image is installed. Ensure that the upgrade procedure was successful.
- Log out of the upgraded switch.
<switch_name>.1 # logout
- If the selected switch is traffic or mixed and accessible through Neutron, continue with Section 2.10.
- If the selected switch is a control or storage switch, continue with the other switch. Continue with Section 2.2.
- If both control or storage switches are upgraded, continue with Section 2.11.
2.10 Recover Traffic Switch from vCIC
Perform the following steps on the upgraded traffic switch:
- Recover the switch from the vCIC:
neutron device-recover <switch_name>
- Note:
- Neutron does not save the active configuration to the switch, and uses SOAP to recover VLAN and additional information instead of using the saved backup configuration. When rebooting or exiting from the switch, never save the configuration: select No when prompted. The switch status changes are available in neutron-server.log as "Change device status".
Example 9 Recover Switch from vCIC
neutron device-recover <cee_region_name>_TRAFFIC_SWB_X770
- Note:
- The switch reboots as part of the recovery process.
- Confirm that the upgraded switch operates properly when
booted from the vCIC:
neutron device-show <switch_name>
Example 10 Neutron Device Show
neutron device-show <cee_region_name>_TRAFFIC_SWA_X670V
- Note:
- The status of the switch must be ACTIVE. It can take about five minutes to have the status displayed.
- If both traffic switches are upgraded, continue with Section 2.11.
- Otherwise, continue with the other switch. Go to Section 2.2.
2.11 Log Out of the Switch
- Log out of the switch.
# logout
- The procedure is complete.
Reference List