1 Introduction
This instruction concerns alarm handling for ScaleIO® related alarm events in the Cloud Execution Environment (CEE), in case a managed ScaleIO solution is used. In case of unmanaged ScaleIO, fault management is handled outside of CEE, so in CEE no ScaleIO alarms are received. For more information on managed and unmanaged ScaleIO, refer to section Introduction in the ScaleIO Architecture Description.
The below sections explain how to identify fault location and get detailed alarm information. The troubleshooting procedure uses tools provided by ScaleIO.
- Note:
- This document contains generic instructions for all ScaleIO alarms. There are no separate OPIs for each individual ScaleIO alarm.
1.1 Alarm Description
Distributed storage alarms are issued for ScaleIO alarm events by the Managed Object (MO) DistributedStorage.
The severity of the alarm is CRITICAL, MAJOR, or MINOR.
For each ScaleIO alarm a Watchmen alarm is mapped in CEE. Identify the relevant ScaleIO alarm with the Additional Text field in the alarm message, see Table 1.
ScaleIO provides the following severities: ALERT_LOW, ALERT_MEDIUM, and ALERT_HIGH. For ScaleIO alarm integration into CEE, and to enable correct alarm handling, alarms are mapped in the following way:
|
ScaleIO Severity Level |
CEE Severity Level |
|
ALERT_LOW |
MINOR |
|
ALERT_MEDIUM |
MAJOR |
|
ALERT_HIGH |
CRITICAL |
For more information on the different ScaleIO alarms, see Section 3.
The following are the consequences for the system if the alarm is not solved:
- Data or data protection can be lost.
- Redundancy can be lost.
- System performance can be reduced.
- Storage capacity can be degraded.
- ScaleIO licenses expire.
The alarm attributes are listed in Table 1.
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
2031719-2031816 |
|
Managed Object Class |
AlarmType |
|
Managed Object Instance |
Region=<name_of_the_region>, |
|
Specific Problem |
Distributed Storage Alarm |
|
Event Type |
<alarm_specific_event_type> |
|
Probable Cause |
<alarm_specific_probable_cause> |
|
Additional Text |
ScaleIO Alarm: <scaleio_alarm_name>(1) |
|
Severity |
CRITICAL (3), MAJOR (4), or MINOR (5) |
(1) The alarm name is based on the ScaleIO REST
alarm message, listed in Table 2, Section 3. For example, the additional text for
ScaleIO alarm “LICENSE_EXPIRED” is “ScaleIO Alarm:
License Expired”.
See Table 2 for detailed alarm information and recommended actions.
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
Before starting this procedure, ensure that you have read the following documents:
- Dell EMC ScaleIO Version 2.x Security Configuration Guide
- Part 4 Reference in Dell EMC ScaleIO Version 2.x User Guide
1.2.2 Tools
No tools are required.
1.2.3 Conditions
Before starting this procedure, ensure that the following conditions are met:
- The virtual IP address of the Meta Data Manager (MDM) cluster is known.
- Information about how to connect to the MDM master and how to use the scli commands is available.
- Administrator user role information is available.
- superuser privileges are available.
2 Procedure
This section describes the procedure to follow when this alarm is received.
2.1 Actions
Follow the below procedure:
- Run the log collection script for MDM, SDS (ScaleIO Data
Server), or SDC (ScaleIO Data Client):
/opt/emc/scaleio/<mdm|sds|sdc>/diag/get_info.sh -d <output_file.zip>
For example, for MDM the command is:
/opt/emc/scaleio/mdm/diag/get_info.sh -d <output_file.zip>
- Fetch the <output_file.zip> file.
- Identify the received alarm from the output and check the ScaleIO log files to get an overview about the fault. Perform the recommended action in Table 2.
- If the alarm ceases, exit this procedure.
If the alarm remains, continue with the advanced log collection steps described in Section 2.2.
2.2 Advanced Log Collection
This section describes how to collect detailed ScaleIO system log files.
- Retrieve the ScaleIO component logs for each component.
For manual log collection, continue with Step 2.
For automated log collection, continue with Step 3.
- For manual log collection follow
the below procedure:
- Issue the below command:
/opt/emc/scaleio/<scaleio_component>/diag/get_info.sh –f
- If the selected node is the Master MDM, use the flags -u <mdm_user>, and -p <mdm_password> instead of –f.
If the selected node contains more than one ScaleIO component, running any script gathers logs for all components on that node.
- Verify that you get an output similar to the following,
which shows that the process of log collection has completed successfully:
Archive /tmp/scaleio-getinfo/getInfoDump.tgz created successfully
When the log collection process completes, a ZIP file containing the logs of all ScaleIO components is created in the node.
To check the options for get_info.sh, use the below command:
get_info.sh --help
- Issue the below command:
- For automated log collection
follow the below procedure:
- Log in to the Installation Manager (IM):
- From the IM main menu, select Maintain.
- Enter the login credentials and click Retrieve system topology. The Maintenance operation screen displays the system topology.
- Click Collect logs.
- Enter the MDM admin password and select one of the following
options:
- Copy repositories: Besides full logs, it includes the MDM repository from installed components. Usual size for the repository is ~306 MB.
- Collect exceptions only: Instead of full logs it collects the ScaleIO core dumps only. By default, ScaleIO core dumps are disabled. Contact customer support if ScaleIO core dumps need to be enabled.
- Last version: Instead of full logs it collects the most recently created log file from each component.
- Click Collect Logs to start the Get Info operation, which is the log collection function of the IM. This operation may take some time to complete, depending on your system topology. Once started, this operation can be rolled back.
- Select the Monitor tab to display log collection progress.
- When the Get Info operation completes, click Download logs to download the log files. A ZIP file, containing all ScaleIO component logs, is downloaded.
- Click Mark operation completed to clear the log files from the IM and enable it to be available for other operations.
- Use the collected information and perform the recommended action in Table 2 to solve the fault.
- If the alarm ceases, exit this procedure.
If the alarm remains, collect troubleshooting data as described in the Data Collection Guideline and contact the next level of maintenance support.
- The job is completed.
3 Additional Information
Table 2 lists alarms that can be received from the ScaleIO system and provides recommended actions for each alarm.
- Note:
- Use the GUI only for alarm monitoring. For acting on alarms and performing the recommended actions described below, use CLI.
|
ScaleIO Alarm Message in GUI |
ScaleIO Alarm Message in REST |
CEE Severity Level |
Recommended Action |
|---|---|---|---|
|
License expired |
LICENSE_EXPIRED |
CRITICAL |
To resume operational mode, contact the next level of maintenance support for license renewal. If you have already renewed your license, install it. |
|
The system's license will expire in n days |
LICENSE_ABOUT_TO_EXPIRE |
MAJOR according to time left and limits |
Contact the next level of maintenance support for license renewal. If you have already renewed your license, install it. |
|
ScaleIO is using a trial license |
TRIAL_LICENSE_USED |
MINOR |
Purchase a license and install it. |
|
Oscillating failures reported |
OBJECT_HAS_OSCILLATING_FAILURES |
MINOR |
Check oscillating failures of the component and take action accordingly. If the oscillating failure does not indicate a problem, change the settings of the oscillating failure window to suppress this alarm. |
|
There are oscillating network failures |
OBJECT_HAS_OSCILLATING_NETWORK_FAILURES |
MINOR |
Check the oscillating failure report that can be accessed from one of the management interfaces. Check if there is a problem with network links, fix it, and restart the counters. |
|
No valid MDM credentials are configured in ScaleIO Gateway |
GW_CONFIGURATION_INVALID_MDM_CREDENTIALS |
CRITICAL |
Configure the MDM credentials in the ScaleIO gateway using SioGWTool. |
|
MDM credentials are not configured in the ScaleIO Gateway |
MDM_CREDENTIALS_ARE_NOT_CONFIGURED |
CRITICAL |
Configure MDM credentials on the ScaleIO gateway using SioGWTool. |
|
The MDM user configured in ScaleIO Gateway requires a password change |
GW_USER_REQUIRES_PW_CHANGE |
CRITICAL |
Configure MDM credentials on the ScaleIO gateway using SioGWTool. |
|
System upgrade is in progress |
UPGRADE_IN_PROGRESS |
MAJOR |
Monitor the upgrade process, and check that it is completed successfully. |
|
ScaleIO Gateway version is too old |
GW_TOO_OLD |
CRITICAL |
Upgrade the ScaleIO gateway to the same version as the rest of your system. |
|
The MDM is not operating in clustered mode |
MDM_NOT_CLUSTERED |
CRITICAL |
MDM cluster was manually set to SINGLE mode. Confirm that this is an expected operation. Working in SINGLE mode is not recommended. Prepare the cluster modules if needed, and return to CLUSTER mode. |
|
MDM fails over frequently |
MDM_FAILS_OVER_FREQUENTLY |
CRITICAL according to disconnect count and hard coded values (2/3/10) |
The MDMs frequently swap ownership. Check the IP network connections and configuration. |
|
Forward rebuild cannot proceed |
FWD_REBUILD_STUCK |
CRITICAL |
Check the system for lack of spare capacity and failed capacity, and either fix the problem or add capacity if necessary. |
|
Backward rebuild cannot proceed |
BKWD_REBUILD_STUCK |
CRITICAL |
Check the system for lack of spare capacity and failed capacity, and either fix the problem or add capacity if necessary. |
|
Rebalance cannot proceed |
REBALANCE_STUCK |
CRITICAL |
Add a physical disk; if this is not possible, reduce the spare policy while maintaining enough spare to sustain a rebuild, if necessary. |
|
The MDM cluster is degraded, and data is not protected |
CLUSTER_DEGRADED |
CRITICAL |
Check that all MDM cluster nodes are functioning correctly, and fix and replace faulty nodes, if necessary, to return to full protection. |
|
MDM_CONNECTION_LOST |
CRITICAL |
Check the connection to the MDM. | |
|
Inactive Protection Domain |
PD_INACTIVE |
MINOR |
Protection Domain was inactivated by a user command. Confirm that this is an expected operation. This is usually done for maintenance. When maintenance is complete, reactivate the Protection Domain. |
|
Storage Pool has failed capacity |
STORAGE_POOL_HAS_FAILED_CAPACITY |
CRITICAL |
For the given storage pool, for some blocks, both primary and secondary copies are inaccessible. Check and fix the state of all devices in the storage pool and all holding devices of the server in the storage pool. |
|
Storage Pool has degraded capacity |
STORAGE_POOL_HAS_DEGRADED_CAPACITY |
MAJOR |
For the given storage pool, for some blocks, one of the two copies is inaccessible. Check if a server is offline or if there is another server hardware-related issue. Check if a storage device is down. |
|
Capacity utilization above critical threshold |
CAPACITY_UTILIZATION_ABOVE_CRITICAL_THRESHOLD |
CRITICAL |
Due to thinly provisioned volumes or snapshot usage, the capacity utilization of the storage pool is reaching a critical threshold. Remove snapshots, if possible, or add physical storage. |
|
Capacity utilization above high threshold |
CAPACITY_UTILIZATION_ABOVE_HIGH_THRESHOLD |
MAJOR |
Due to thinly provisioned volumes or snapshot usage, the capacity utilization of the storage pool is reaching a high threshold. Remove snapshots, if possible, or add physical storage. |
|
Failure recovery capacity is below the threshold |
FAILURE_RECOVERY_CAPACITY_BELOW_THRESHOLD |
MAJOR |
The capacity available for recovery in a degraded storage event is lower than the predefined threshold. Replace failed hardware or add more physical storage. |
|
Configured spare capacity is smaller than largest fault unit |
CONFIGURED_SPARE_CAPACITY_SMALLER_THAN_LARGEST_FAULT_UNIT(1) |
MINOR |
Increase the spare percentage configured in the system for the storage pool, so that the capacity reserved for failure recovery is larger than the largest fault unit in the storage pool. |
|
The Storage Pool relies too heavily (over 50%) on capacity from a single SDS or Fault Set. Balance capacity over other SDSs or Fault Sets. |
STORAGE_POOL_UNBALANCED |
MAJOR |
Move some physical disks from the large SDS to the others, or add disks to the smaller SDS in order to approximate the capacity of the large SDS as much as possible. |
|
Storage Pool does not meet the minimum requirement of 3 fault units |
NOT_ENOUGH_FAULT_UNITS_IN_SP |
MAJOR |
Add more SDSs to the storage pool to meet the minimum requirement of three hosts. |
|
There are cluster certificates pending approval. For more information, open System Settings>Certificates. |
UNTRUSTED_CERTIFICATE |
MAJOR |
Check the certificates and proceed at your own risk. For more information, open System Settings>Certificates. |
|
Master MDM Certificate is about to expire |
CERTIFICATE_ABOUT_TO_EXPIRE |
CRITICAL |
Install a valid SSL certificate on the MDM before the old one expires. |
|
Master MDM Certificate has expired |
MDM_CERTIFICATE_EXPIRED |
CRITICAL |
Install a valid SSL certificate on the host. |
|
Secure connection disabled on MDM |
MDM_SECURE_CONNECTION_DISABLED |
CRITICAL |
Enable secure connections on the MDM to protect your login information. |
|
The self-signed certificate presented by the Master MDM is not trusted |
MDM_SELF_SIGNED_CERTIFICATE_NOT_TRUSTED |
CRITICAL |
Check the certificate, and proceed at your own risk. |
|
MDM does not support secure connections |
MDM_SECURE_CONNECTION_NOT_SUPPORTED |
CRITICAL |
Check MDM cluster nodes. |
|
The validity period of the certificate presented by the Master MDM starts in the future |
MDM_CERTIFICATE_NOT_YET_VALID |
CRITICAL |
The time and date on the computer where the certificate was created is not consistent with the time and date set in the ScaleIO system. Replace the certificate or fix the system time. |
|
The Certificate Authority that signed the Master MDM's certificate is not trusted |
MDM_CA_SIGNED_CERTIFICATE_CA_NOT_TRUSTED |
CRITICAL |
Proceed at your own risk. |
|
SDS is disconnected |
SDS_DISCONNECTED |
MAJOR |
The SDS service can be down or unreachable over the network. Verify that the SDS service is up and running and that the network is properly connected. |
|
SDS disconnects frequently |
SDS_DISCONNECTS_FREQUENTLY |
MAJOR according to disconnect count and hard-coded |
The SDS connection is fluctuating due to an unstable network connection. Check the SDS data network connection for packet drops, and try to disconnect one of the ports to see if the SDS disconnection issue is resolved by using only one port. If this does not resolve the issue, switch to the other port. If there is still an issue, it can be due to a faulty NIC, faulty switch ports, or a faulty switch. If there is no issue with another switch, the issue was switch-related. Otherwise, the issue can be due to a faulty NIC, which requires NIC replacement. |
|
Memory allocation for RAM Read Cache failed on SDS |
SDS_RMCACHE_MEMORY_ALLOCATION_FAILED |
MINOR |
The system failed to allocate memory to the SDS RAM read cache. For 32 GB RAM or less, up to 50% of the memory can be allocated for caching. From 32 GB or more, up to 75% of the memory can be allocated for caching. Reduce the configured RAM read cache memory to match the allocation conditions. |
|
DRL mode: Hardened |
DRL_MODE_NON_VOLATILE |
MINOR |
DRL mode is configured to Hardened instead of Volatile. Both modes are configurable. |
|
RFcache card I/O error |
RFCACHE_CARD_IO_ERROR |
MINOR |
Disable caching on the device and check the health of the device, because it can be faulty. If necessary, replace the device. |
|
RFcache skipped due to heavy load |
RFCACHE_CACHE_SKIP_DUE_TO_HEAVY_LOAD |
MINOR |
Read flash cache is working under a heavy load, and therefore has skipped some IOs. This is a temporary error which can resolve itself. If it persists, try to balance the storage pool contents across more SDSs, or add more cache cards. |
|
RFcache IO stuck error |
RFCACHE_IO_STUCK_ERROR |
MINOR |
IO has become stuck on the cache device. Disable caching on the device and check the health of the device, because it can be faulty. If necessary, replace the device. |
|
RFcache resources are low |
RFCACHE_LOW_RESOURCES |
MINOR |
There is not enough RAM available on the server for read flash cache optimal operation. Increase the amount of available RAM. |
|
RFcache driver path is invalid |
RFCACHE_INVALID_DRIVER_PATH |
MINOR |
The read flash cache driver xcache is either not installed, or was installed in the wrong location. Install the driver, and contact the next level of maintenance support if the problem persists. |
|
RFcache source configuration is inconsistent |
RFCACHE_INCONSISTENT_SOURCE_CONFIGURATION |
MINOR |
Check RFcache state of all disks in the pool and adjust them so that all disks have the same caching state. |
|
RFcache source configuration is inconsistent |
RFCACHE_INCONSISTENT_CACHE_CONFIGURATION |
MINOR |
Query the system to determine what is not consistent in the configurations of the read flash cache driver and the SDS where the cache device is located. |
|
RFcache device does not exist |
RFCACHE_DEVICE_DOES_NOT_EXIST |
MINOR |
You tried to add a cache device that does not exist. Check and fix read flash cache configuration. |
|
RFcache API mismatch |
RFCACHE_API_ERROR_MISMACH |
MINOR |
The read flash cache xcache driver version and SDS version do not match.Upgrade them to the same version. If the problem persists, contact the next level of maintenance support. |
|
SDS is in Maintenance Mode |
SDS_IN_MAINTENANCE |
MINOR |
The SDS is currently in maintenance mode. Exit maintenance mode once maintenance is complete. If a non-Disruptive Upgrade (NDU) is in progress, ignore this warning. |
|
Device failed |
DEVICE_FAILED |
MAJOR |
The SDS device cannot be opened, read from or written to. Validate the device state. Check the cause of the error, and determine if it is a human error or a system malfunction. Check hardware if needed. |
|
Device test is done and device is pending activation |
DEVICE_PENDING_ACTIVATION |
MINOR |
The SDS device has been added and tested. Activate the SDS device. |
|
Device has fixed read errors |
FIXED_READ_ERROR_COUNT_ABOVE_MINOR_THRESHOLD |
MAJOR if counter > 0 |
Read from the SDS device failed. Data was corrected from the other copy. No action is required, but note that the device can be faulty. |
|
Device has fixed read errors |
FIXED_READ_ERROR_COUNT_ABOVE_CRITICAL_THRESHOLD |
CRITICAL if counter >= 5 |
SDS device read failed more than five times. Replace the physical device. |
|
The SDC is either down or unreachable over the network |
SDC_DISCONNECTED |
MAJOR |
Verify that the SDC service is up and running and that the network is properly configured and connected. |
|
No more SDCs can be defined on this system; the maximum has been reached |
SDC_MAX_COUNT |
MAJOR |
The maximum number of SDCs in the system has been reached. |
(1) Due to SNMP related character limits in Watchmen, Additional Text for this alarm is “ScaleIO Alarm:
Spare Capacity Smaller Than Largest Fault Unit”.