1 Introduction
This instruction concerns alarm handling.
1.1 Alarm Description
This section describes the Data Path Connection Failure alarm.
The Data Path Connection Failure alarm is issued by the Managed Object (MO) DstDPN when the data path connectivity is lost between:
- The Data Plane Nodes (DPNs)
- The DPN and Data Center Gateway (DC-GW)
- The DPN and the HW VXLAN Tunnel End Point (VTEP)
- Note:
- The Cloud SDN Controller (CSC) generates this alarm only if the Cloud SDN Switch (CSS) switch port failure affects DPN connectivity.
The severity of the alarm is CRITICAL.
Possible alarm causes and fault locations are explained in Table 1.
|
Alarm |
Description |
Fault |
Fault |
Impact |
|---|---|---|---|---|
|
Data path connectivity is lost between: |
The data path connectivity is lost between a pair of CSSs. |
|
The service provided by the component is degraded or lost. |
The following is the consequence for the node if the alarm is not solved:
- The service provided by the component is degraded or lost.
The alarm attributes are listed in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
2162690 |
|
Managed Object Class |
DstDPN |
|
Managed Object Instance |
Region=<name_of_the_region>, or Region=<name_of_the_region>, or Region=<name_of_the_region>, |
|
Specific Problem |
SDNc, data path connectivity between DPNs is lost |
|
Event Type |
communicationsAlarm |
|
Probable Cause |
302 |
|
Additional Text |
:<hw_uuid_of_corresponding_server>:<hw_uuid_of_corresponding_server>(1) or :<hw_uuid_of_corresponding_server>:IpAddress(2) or :<hw_uuid_of_corresponding_server>(3) |
|
Severity |
CRITICAL |
(1) When the connectivity is lost between DPNs.
(2) When the connectivity is lost between
DPN and DC-GW.
(3) When the connectivity is lost between
DPN and HW-VTEP.
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
For more information on SDN alarms, refer to the following SDN documents:
- Alarms, Reference [1] for CSC (controller)
- CSS Troubleshooting Guide, Reference [2] for CSS (switch)
1.2.2 Tools
No tools are required.
1.2.3 Conditions
Not applicable.
2 Procedure
This section describes the procedure to follow when this alarm is received.
- If the connectivity is lost between the DPNs, see Section 2.1.1.
- If the connectivity is lost between a DPN and the DC-GW, see Section 2.1.2.
- If the connectivity is lost between a DPN and the HW-VTEP, see Section 2.1.3.
2.1 Actions
2.1.1 Actions for Data Path Connection Failure Between DPNs
Do the following:
- Identify the affected compute servers:
- On source and destination CSS hosts, check the status
of CSS.
- service openvswitch-switch status
If CSS is down, restart it.
service openvswitch-switch start
- Check whether data connectivity between the source and
destination CSSs is operational:
ping <destination_css_ip>
An example output where the ping is successful is shown below.
cic-1:~ # ping 10.184.22.13
PING 10.184.22.13 (10.184.22.13) 56(84) bytes of data.
64 bytes from 10.184.22.13: icmp_seq=1 ttl=254 time=1.03 ms
64 bytes from 10.184.22.13: icmp_seq=2 ttl=254 time=0.867 ms
64 bytes from 10.184.22.13: icmp_seq=3 ttl=254 time=0.780 ms
^C
--- 10.184.22.13 ping statistics ---
3 packets transmitted, 3 received, 0% packet loss, time 2002ms
rtt min/avg/max/mdev = 0.780/0.895/1.038/0.107 msAn example output where the ping fails is shown below.
cic-1:~ # ping 10.184.22.99
PING 10.184.22.99 (10.184.22.99) 56(84) bytes of data.
^C
--- 10.184.22.99 ping statistics ---
6 packets transmitted, 0 received, 100% packet loss, time 5038msIf the ping fails, this can indicate an underlay fault. Refer to alarm topic LostConnection in the HDS documentation, Reference [3], and continue with Section 2.2.
If the connection is reestablished and the alarm ceases, exit this procedure. Else, continue with Section 2.2.
- service openvswitch-switch status
2.1.2 Actions for Data Path Connection Failure Between DPN and DC-GW
Do the following:
- Identify the affected compute servers:
- On source and destination CSS hosts, check the status
of CSS.
- service openvswitch-switch status
If CSS is down, restart it.
service openvswitch-switch start
- Check whether data connectivity between the CSS and the
DC-GW is operational:
ping <destination_dc-gw_ip>
If the ping fails, this can indicate an underlay fault. Refer to alarm topic LostConnection in the HDS documentation, Reference [3], and continue with Section 2.2.
If the connection is reestablished and the alarm ceases, exit this procedure. Else, continue with Section 2.2.
- service openvswitch-switch status
2.1.3 Data Path Connection Failure Between DPN and HW-VTEP
Do the following:
- Identify the affected compute servers:
- From the alarm output, note down the following data:
- Match the HW UUID to the specific compute server with one of the following tools:
- On source and destination CSS hosts, check the status
of CSS.
- service openvswitch-switch status
If CSS is down, restart it.
service openvswitch-switch start
- Check whether data connectivity between the CSS and the
HW-VTEP is operational:
ping <destination_hwvtep_device_ip>
If the ping fails, this can indicate an underlay fault. Refer to alarm topic LostConnection in the HDS documentation, Reference [3], and continue with Section 2.2.
If the connection is reestablished and the alarm ceases, exit this procedure. Else, continue with Section 2.2.
- service openvswitch-switch status
2.2 Collect Troubleshooting Data
If the connection is not reestablished, follow the below steps:
- Collect troubleshooting data as described in the Data Collection Guideline.
- Contact the next level of maintenance support.
Further actions are outside the scope of this instruction.
- The job is completed.